St Andrews Est-LR041228ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
Concrete Compression Test
Report
Tested For: ST. ANDREWS LAND COMPANY
ATTN: TERRY HOLMES
2629 DICKERSON PKWY, STE 110
CARROLLTON, TX 75007
Fax Number: (972) 242-2931
Project Desc: ST. ANDREWS ESTATES
OFF DEFOREST RD JUST WEST OF STRATFORD LN
Our Report No.: 04219-58
Issue Date: 12/28/2004
FIELD DA TA
Placement Location:
Date Placed:
Time Placed:
Slump (ASTM C-t43):
Air Content:
Air Temperature:
Specimen Temperature:
Date Received:
Delivery Method:
Field Data Submitted By:
Mix Data Submitted By:
INLET TOP, ST. ANDREWS LN. ~ STATION 3+50
12/08104
1:17 PM
5.5
N/A
65
81
12/09/04
PICKED UP BY ALPHA
CO'I-TON, DERRICK
N/A
Plant Number: N/A
Delivery Ticket No,: N/A
Made By: ALPHA
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI:
41 LAB C-1231 12/15/04 7 12 N/A 6 28.27 56440 2000
42 LAB 01/05/05 28 12 N/A 6 28.27 0
43 LAB 01/05/05 28 12 N/A 6 28.27 0
44 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3000
Results to Data: N/A
CC: ST ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL
Respectfully Submitted By: ./.~ of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed
exceptwithexpressapprovalofALPHA Theuseofournarneandtestresultsmustrecffiveourwritlenapproval Test results and reports apply only to the samples
tested and/or observed, and are not indicative of the c~ualities of apparently identical or similar specimens
Geetechnlcal Engineering * Construction Materials Testing * Environmental Engineering * Consulting 40155
ALPHA TESTING, INC.
2209 Wisconsin St,, Suite 100
Dallas, Texas 75229
(972) 620-8911
Concrete Compression Test
Report
Tested For: ST. ANDREWS LAND COMPANY
ATrN: TERRY HOLMES
2629 DICKERSON PKWY, STE 110
CARROLLTON, TX 75007
Fax Number: (972) 242-2931
Project Desc: ST. ANDREWS ESTATES
OFF DEFOREST RD JUST WEST OF STRATFORD LN
Our Report No.: 04219-59
Issue Date: 12/2812004
FIELD DA TA
Placement Location:
Date Placed:
Time Placed:
Slump (ASTM C-143):
Air Content:
Air Temperature:
Specimen Temperature:
Date Received:
Delivery Method:
Field Data Submitted By:
Mix Data Submitted By:
INLET TOPS, ST. ANDREWS LN. ~ STATION 11+72 & 5+00
12/10/04
12:20 PM
3.5
N/A
65
79
N/A
PICKED UP BY ALPHA
COTTON, DERRICK
LATINOS
Plant Number: -3500
Delivery Ticket No.: N/A
Made By:
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Da)ts): Length Width Diameter Sq. In. Load: PS1:
45 LAB C-1231 12/17/O4 7 12 N/A 6 28.27 64170 2270
46 LAB 01/07/05 28 12 N/A 6 28.27 0
47 LAB 01/07105 28 12 N/A 6 28.27 0
48 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3000
Results to Date: N/A
CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CiTY OF COPPELL
,/
Respectfully Submitted By: ,~/ of Alpha Testing, Inc,
Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed
except w~th express approval of ALPHA. The use of our name and test results must receive our written approval Test results and reports apply only to the samples
tested and/or observed, and are not indicative of the qualities of apparentty identical or similar specimens
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting
40226