Loading...
St Andrews Est-LR041227 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 ~-,~ Tested For: ST. AND~E~vs LAND COMPANY ATTN? ~ERRY HOLMES 2621~ DICKERSON PKVVY, STE 110 CA~ROLLTON, TX 75007 Fax Number: (97~) 242-2931 Project Desc: ST. ANdrEWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Concrete Compression Test Report Our Repor~ No.: 04219-51 issue Date: 12/27/2004 FIELD DATA Placement Location: Date Placed: 11/19/04 Time Placed: 9:42 AM Slump (ASTM C-143): 5.0 Air Content: 2.25 (ASTM C-173) Air Temperature: 65 Specimen Temperature: 67 Date Received: 11120104 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: TINOCO, ARTHURO Mix Data Submitted By: LMC PAVING, N. BOUND ST. ANDREWS ~ STATION 6+75 Plant Number: Delivery Ticket No.: Made By: Cure? Specification: 7-3600 7147166 ALPHA ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSh 37 LAB C-1231 11/26/04 7 12 N/A 6 28.27 151060 5340 38 LAB C-1231 12/17/04 28 12 N/A 6 28.27 177140 6270 39 LAB C-1231 12/17/04 28 12 N/A 6 28.27 178650 6320 40 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: ~ PASS CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL ~ i~, Respectfully Submitted By: ~ ~/~_/ of Alpha Testing, Inc. tested and/or observed, and are not indicative of the dualities of apparently identical or similar spec,rne~s Geotechnical Engineering * Construction Mate~als Testing * Environmental Engineering * Consulting 39988