St Andrews Est-LR041227 ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911 ~-,~
Tested For: ST. AND~E~vs LAND COMPANY
ATTN? ~ERRY HOLMES
2621~ DICKERSON PKVVY, STE 110
CA~ROLLTON, TX 75007
Fax Number: (97~) 242-2931
Project Desc: ST. ANdrEWS ESTATES
OFF DEFOREST RD JUST WEST OF STRATFORD LN
Concrete Compression Test
Report
Our Repor~ No.: 04219-51
issue Date: 12/27/2004
FIELD DATA
Placement Location:
Date Placed: 11/19/04
Time Placed: 9:42 AM
Slump (ASTM C-143): 5.0
Air Content: 2.25 (ASTM C-173)
Air Temperature: 65
Specimen Temperature: 67
Date Received: 11120104
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: TINOCO, ARTHURO
Mix Data Submitted By: LMC
PAVING, N. BOUND ST. ANDREWS ~ STATION 6+75
Plant Number:
Delivery Ticket No.:
Made By:
Cure? Specification:
7-3600
7147166
ALPHA
ASTM C-31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSh
37 LAB C-1231 11/26/04 7 12 N/A 6 28.27 151060 5340
38 LAB C-1231 12/17/04 28 12 N/A 6 28.27 177140 6270
39 LAB C-1231 12/17/04 28 12 N/A 6 28.27 178650 6320
40 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3000
Results to Date: ~ PASS
CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL ~ i~,
Respectfully Submitted By: ~ ~/~_/ of Alpha Testing, Inc.
tested and/or observed, and are not indicative of the dualities of apparently identical or similar spec,rne~s
Geotechnical Engineering * Construction Mate~als Testing * Environmental Engineering * Consulting