Loading...
St Andrews Est-LR041221Teated For: ALPHA TESTING, INC. 2209 wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 ST. ANDREWS LAND COMPANY ATTN: TERRY HOLMES 2629 DICKERSON PKWY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Concrete Compression Test Report Our Report No.: 04219-52 Issue Date: 12/21/2004 Project Desc: ST, ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN FIELD DATA Placement Location: PAVING, ST. ANDREWS LN ~ STATION 11+50 Date Placed: 11/16/04 Time Placed: 8:10 AM Slump (ASTM C-143): 5.0 Air Content: 5.0 (ASTM C-173) Air Temperature: 65 Specimen Tembemture: 84 Date Received: 11/17104 Delivery Method: PICKED UP BY ALPHA Field Date Submitted By: ALEGRIA, ROBERT Mix Data Submitted By: LMC Plant Number: 3-3600 Delivery Ticket No.: 3186438 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RES UL TS Lab Cum Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Da}/s): Length Width Diameter Sq. In. Load: PSI: 13 LAB C-1231 11/23/04 7 12 N/A 6 28.27 107560 3800 14 LAB C-1231 12/14/04 28 12 N/A 6 28.27 144940 5130 15 LAB C-1231 12/14/04 28 12 N/A 6 28.27 144860 5120 16 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: PASS CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL Respectfully Submitted By: ~'~,~" ~ of Alpha Testing, Inc. Our test results and reports are for the exc~use of the Client (and their designated recepients on fl~e in our office and shall not be reproduced and/or distributed except with express approval of ALPH _,H~fT~e u~e?f our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens Geotechnical Enginesdng * Construction Materials Testing * Environmental Engineering * Consulting 39935 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: ST. ANDREWS LAND COMPANY ATTN: TERRY HOLMES 2629 DICKERSON PKWY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Project Desc: ST. ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Our Report No.: 04219-53 Issue Date: 12/21/2004 FIELD DA TA Placement Location: Date Placed: Time Placed: Slump (A~TM C-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Delivery Method: Field Data Submitted By: Mix Data Submitted By: PAVING, STONEWICK LN. ~ STATION 0+50 11/16/04 11:30 AM 2.5 4.0 (ASTM C-173) 68 84 11117/04 PICKED UP BY ALPHA ALEGRIA, ROBERT LMC Plant Number: 3-3600 Delivery Ticket No.: 3185466 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 17 LAB C-1231 11/23/04 7 12 N/A 6 28.27 118810 4200 18 LAB C-1231 12/14/04 28 12 N/A 6 28.27 151670 5370 19 LAB C-1231 12/14/04 28 12 N/A 6 28.27 165310 5850 20 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: PASS CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL Respectfully Submitted By: ~.-~-~- ~ of Alpha Testing, Inc. Our test results and reports are for the excl~the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 39936 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: ST. ANDREWS LAND COMPANY A'CI'N: TERRY HOLMES 2629 DICKERSON PKVVY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Project Desc: ST. ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Our Repol/No.: 04219-54 issue Data: 1212112004 FIELD DA TA Placement Location: Data Placed: Time Placed: Slump (ASTM C-143): Air Contant: Air Temperature: Specimen Temperature: Oata Received: Delivery Method: Field Data Submitted By: Mix Data Submitted By: PAVING, ST. ANDREWS LN ¢~ STATION 8+00 11/16/04 1:15 PM 3.5 4.5 (ASTM C-173) 68 86 11 / 17/04 PICKED UP BY ALPHA ALEGRIA, ROBERT LMC Plant Number: 3-3600 Delivery Ticket No.: 3186484 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Da)ts): Length Width Diameter Sq. In. Load: PSi: 21 LAB C-1231 11/23/04 7 12 N/A 6 28,27 131590 4650 22 LAB C-1231 12/14104 28 12 N/A 6 28.27 155550 5500 23 LAB C-1231 12/14/04 28 12 N/A 6 28.27 150360 5320 24 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL Respectfully Submitted By: ,- ~~ of Alpha Testing, Inc tested and/or observed, and are not indiCative of the qualities of apparently identiCal or similar specimens Geotechnlsal Engineering * Construction Materials Testing * Environmental Engineering * Consulting 39937 ALPHA TESTING, INC. 2209 Wisconsin St,, Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: ST. ANDREWS LAND COMPANY A'FI'N: TERRY HOLMES 2629 DICKERSON PKWY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Project Desc: ST. ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Our Report No.: 04219-55 Issue Date: 12/21/2004 FIELD DA TA Placement Location: Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: PAVING, ST. ANDREWS LN @ STATION 6+00 11/16104 2:15 PM 3.5 5.0 (ASTM C-173) 68 Specimen Temperature: 87 Date Received: 11/17104 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: ALEORIA, ROBERT Mix Data Submitted By: LMC Plant Number: 7-3600 Delivery Ticket No.: 7147125 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 25 LAB C-1231 11/23/04 7 12 N/A 6 28.27 127220 4500 26 LAB C-1231 12/14/04 28 12 N/A 6 28.27 161290 5710 27 LAS C-1231 12/14/04 28 12 N/A 6 28.27 158200 5600 28 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: PASS CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING. CITY OF COPPELL Respectfully Submitted By: ..--~?-.--,.~ .,~-----. of Alpha Testing, Inc. tested and/or obsecved, and are not indicative of the qualities of apparently identical or similar specimens Geotechntcal Engineering * Construction Materials Testing" Environmental Engineering * Consulting 39938 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: ST. ANDREWS LAND COMPANY ATI'N: TERRY HOLMES 2629 DICKERSON PKWY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Project Desc: ST. ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Our Report No.: 04219-56 Issue Date: 12/21/2004 FIELD DA TA Placement Location: PAVING, ST. ANDREWS LN. ~ STATION 4+00 Date Placed: 11/16/04 Time Placed: 2:55 PM Slump (ASTM C-143): 3.5 Air Content: 5.0 (ASTM C-173) Air Temperature: 68 Specimen Temperature: 85 Date Received: 11/17104 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: ALEGRIA, ROBERT Mix Date Submitted By: LMC Plant Number: 3-3600 Delivery Ticket No.: 3186503 Made By: ALPHA Cured Specification: ASTM C~31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 29 LAB C-1231 11/23/04 7 12 N/A 6 28.27 118440 4190 30 LAB C-1231 12114/04 28 12 N/A 6 28.27 156660 5540 31 LAB C-1231 12/14/04 28 12 N/A 6 28.27 151450 5360 32 LAB HOLD HOLD 12 N/A 6 28,27 0 Specifications: 28 3000 Results to Date: PASS cc: ST ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL Respectfully Submitted By: ~ ~ of Alpha Testing, Inc, Our test results and reports are for the excl~he Client (and their designated recepients on file in our office) and st3all not be reproduced and/or distributed except with express approval of ALPHA Tile use of our name and test results must receive our written approval Test results and reports apply only to t~e samples tested and/or observed, and are not indicative of the dualities of apparently identical or similar specimens Geotechnical Engineering * Construction Materials Testing * Environmental Enginoaring * Consulting 39939 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: ST. ANDREWS LAND COMPANY ATTN: TERRY HOLMES 2629 DICKERSON PKVVY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Project Desc: ST. ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Our Report No.: 04219-57 Issue Date: 12121/2004 FIELD DA TA Placement Location: Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Delivery Method: Field Data Submitted By: Mix Data Submitted By: PAVING, ST. ANDREWS LN. ~ STATION 1+34.37 11/16/04 4:00 PM 3~5 4.5 (ASTM C-173) 68 87 11/17/04 PICKED UP BY ALPHA ALEGRIA, ROBERT LMC Plant Number: 3-3600 Delivery Ticket No.: 3186523 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Lenl~th Width Diameter Sq. In. Load: PSI: 33 LAB C-1231 11/23/04 7 12 N/A 6 28.27 107370 3800 34 LAB C-1231 12/14/04 28 12 N/A 6 28.27 137410 4860 35 LAB C-1231 12114/04 28 12 N/A 6 28.27 140550 4970 36 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: PASS CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL 0 U r test ~ees:l'P~s ::;Itl:poS ur tsb~mr i:f~;t h~::xcld ~~heir design a t ed~ ~"~ recepients on file in our office)and shall notbe rep rOdUlc( dha n (/or ,diS.rib,[ t edof Ap aTesing, nc except with express approval of ALPHA. The use of our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of appa rent~y identical or similar spec*mens Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 39940