SS9402C-CS 960506DATE: TO: FROM: RE: COPPELL ENGINEERING UTILITIES DIVISION MEMORANDUM May 6, 1996 Garreth Campbell, Construction Inspector Matt M. Cast, Superintendent of Public Services Walk thru for Grapevine Sewer A walk-thru on the above referenced project was conducted on 5/6/96 and the items below were found to be deficient. 1. Sta. 42+52.27 grout needed, rain pan, chimney seal. Abandon existing manhole. 2. 40+35.00 Rain pan, Chimney seal, line is very dirty. 35+40.41 rain pan, chimney seal, inflow on incoming invert. No access to line on Loch Lane. 33+47.78 grout manhole, chimney seal, holding 1/3 pipe of water, all seams need grout for inflow. 5. Plans show that manhole coming from Bums should still be in place. 30+46.68 Raise to grade, grout, chimney seal, ra/n pan. Need access to N. Coppell line, abandon old manhole. 25+47.35 grout manhole, chimney seal, remove sand bag. What is line coming in from s.w. 2 ft. off floor, line needs cleaning. o 20+56.00 chimney seal, poor compaction, seam leaking where 4 ft. meets 5ft. Need class 400 lid and ring installed. 9. 16+36.00 grout, chimney seal, re-center ring & lid. 10. 12+10.00 grout, chimney seal, re-center lid & ring, clean pipe & floor, crack in wall, existing manhole at park needs to be raised to grade. Walk Through for Grapevine Sewer Page 2 11. 12. 13. 14. 15. 16. 8+54.53 (.57) chimney seal. 5+41.02 chimney seal 26in. of riser. Rings makes manhole neck too long. Manhole before inverted siphon saw no sra. # chimney seal torn and has no lower band, invert needs work badly, plug old line and abandon old manhole @ edge of street. 1+62.33 missing bolts, flow needs to be diverted into siphon box. Get old manhole lid & ring out of creek bottom. 0+40 needs gaskets on bolts for bolt down. 0+08 needs ring reset to cone. Please ensure that these items get taken care of and if you have any questions, please give me a call. MMC/dg