Freeport NIP(8.0)-LR050117Client: neers Duke Realty Services, LP Mr. Brian Styaley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, For~ Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Services: Report No.: 224828 Project No.: 049245 Date of Service: 12/18/2004 Report Date: 01/17/2005 Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA MEASURED STRENGTH: SLUMP (in): Am (%): TEST METHOD: CONTRACTOR: Duke Construction CONCRETE SUPPLIER: Southern Star PLANT: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 3" - 5" 4% - 6% ASTM C-172 ASTM C-31 ASIM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 except 912 MIX DESIGN LD.: 7752 PLACEMENT DATE: 12/18/2004 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 7:30am BATCH TIME: 6:40am TEMPERATURE (F) ~ AIR 36 F CONCRETE: 60 F TRUCKNO: 648 TICI~TNO: 761867 AIR CONTENT (%): 6.0 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: See below SAMPLE LOCATION: REPORT OF TESTS 10' north from southeast corner, section south of machine pad Concrete Compressive Cylinder 6" x 12" SLUMP (inches) 5.0 CYLINDER MARKED DATE SET NO. TESTED 1 1 12/25/2004 1 2 01/15/2005 1 3 01/15/2005 1 4 Hold Placement location: side lot, east half, MAXIMUM AGE DIAMETER AREA LOAD (days) (inches) (sq.in.) (lbs. ~rce) 7 6.00 28.26 108880 28 6.00 28.26 133200 28 6.00 28.26 132640 Average COMPRESSIVE STRENGTH FRACTURE (psi) TYPE 3850 Unbonded Cap 4710 Unbonded Cap 4690 Unbonded Cap 4700 Paving, northwest dock floors and walls: Building XI, west north and south of machine room pad; 2' by 95' section west LlivlITAT1ONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appeaxance, performance, ere) or any other feature of similar subject manet provided by persons or conditions over which we have no control. Our leners and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the wriaen approval of Rone Engineers, Ltd. 01SS Page ! of 10 Report No.: 224828 RoneEngineers Project No.: 049245 Client: Duke Realty Services, LP l~lll edge of machine pad; northwest dock door; floors 1 and 2 south from northwest corner of Building XI; doc door walls 3 and 4 south from northwest corner of Building XI. Water added at site: 10 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibilit~ for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in f~l] without the written approval of Rone Engineers, Ltd. 01SS Page 2 of 10 Rc ineers Client: Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 224828 Project No.: 049245 Date of Service: 12/18/2004 Report Date: 01/17/2005 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUIVlP (in): AIR (%): TEST METHOD: CONTRACTOR: Duke Construction CONCRETE SEqaPLIER: Southern Star PLANT: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 3"- 5" 4% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MLX DESIGN I.D.: 7752 PLACEMENT DATE: 12/18/2004 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 8:lSam BATCHTIME: 7:45am TEMPERATURE (F)- AIR 36 F CONCRETE: 59 F TRUCK NO: 1883 TlCKET NO: 761873 AIR CONTENT (%): 6.0 UNITWEIGHT(pel): NA OVERALL PLACEMENT LOCATION: See below SAMPLE LOCATION: REPORT OF TESTS 70' south, 20' east from northwest comer, south of machine pad MEASURED SLUMP (inches) 5.0 Concrete Compressive Cylinder 6" x 12" CYLINDER MARKED SET NO. DATE AGE DIAMETER TESTED (days) (inches) M,~XIMUM COMPRESSIVE AREA LOAD STRENGTH FRACTURE (sq.in.) (lbs. force) (psi) TYPE 2 1 12/25/2004 7 6.00 28.26 116180 4110 Unbonded Cap 2 2 01/15/2005 28 6.00 28.26 2 3 01/15/2005 28 6.00 28.26 142930 5050 Unbonded Cap 138910 4910 Unbonded Cap Average 4980 2 4 Hold Placement location: Paving, northwest dock floors and walls: Building XI, west side lot, east half, north and south of machine room pad; 2' by 95' section west LhMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc ) or any other feature of similar subject mailer provided by persons or conditions over which we have no ¢onltol Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in f~ll without the written approval of Rone Engineers, Ltd. 01SS Page 3 of 10 Report No.: 224828 Project No.: 049245 Client: Duke Realty Services, LP edge of machine pad; northwest dock door; floors 1 and 2 south from northwest corner of Building XI; doc door walls 3 and 4 south from northwest corner of Building XI. Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for v~fiation in quality (composition, appearance, performance, etc) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients m whom they are addressed and shall not be reproduced except in fulI without the written approval of Rone Engineers, Ltd. 01SS Page 4 of 10 Client: ineers Duke Realty Services, LP Mr. Brian Slraley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XI1 Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 224828 Project No.: 049245 Date of Service: 12/18/2004 Report Date: 01/17/2005 Obtain samples of fi-esh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Duke Construction CONCRETE SUPPLIER: Southerll Star PLANT: 27 SPECIFICATION REQUIREMENIS 4000 psi ~ 28 Days 3"- 5" 4% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 12/18/2004 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 9:15am BATCHTIME: 8:48am TEMPERATURE (F) - AIR 43 E CONCRETE: 63 E TRUCK NO: 1827 TIC~;~T NO: 761802 AIR CONTENT (%): 5.8 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: See below SAMPLE LOCATION: 10' south, 15' east fi-om nor[hwest REPORT OF TESTS co~ner, south of machine pad MEASURED SLUMP (inches) 4.75 Concrete Compressive Cylinder 6" x 12" CYLINDER MARKED DATE SET NO. TESTED MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH FRACTURE (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 3 1 12/25/2004 3 2 01/15/2005 3 3 01/15/2005 3 4 Hold Placement location: 7 6.00 28.26 127620 4510 Unbonded Cap 28 6.00 28.26 146920 5200 Unbonded Cap 28 6.00 28.26 157300 5560 Unbonded Cap Average 5380 Paving, northwest dock floors and walls: Building XI, west side lot, east half, north and south of machine room pad; 2' by 95' section west LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients m whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01SS Page 5 of I0 Report No.: 224828 Project No.: 049245 Client: Duke Realty Services, LP edge of machine pad; northwest dock door; floors 1 and 2 south from northwest corner of Building XI; doc door walls 3 and 4 south from northwest corner of Building XI. Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing, We ~ssume no responsibility for variation in quality (composition, appearance, performance, etc) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the wri~en approval of Rone Engineers, Ltd. 01SS Page 6 of 10 Client: ineers Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Project: Freeport XI & XII Coppell, Texas Report No.: 224828 Project No.: 049245 Date of Service: 12/18/2004 Report Date: 01/17/2005 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTILs, CTOR: Duke Construction CONCRETE SUPPLIER: Southern Star PLANT: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 3" - 5" 4% - 6% ASTM C- 172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C- 1064 ASTM C-1231 ASTM C-39 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 12/18/2004 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 10:20am BATCHTIME: 9:54am TEMPERATURE (F) - AIR NAv CONCRETE: 66 TRUCK NO: 1815 TICKET NO: 761891 AIR CONTENT (%): 5.9 UNITWE1GHT(pc0: NA OVERALL PLACEMENT LOCATION: See below SAMPLE LOCATION: REPORT OF TESTS 50' north, 30' east fi.om southwest comer, north of machine pad MEASURED SLUMP (inches) 5.0 Concrete Compressive Cylinder 6" x 12" CYLINDER MARKED DATE AGE D1AMETER SET NO. TESTED (days) (inches) MAXIMUM COMPRESSIVE AREA LOAD STRENGTH (sq.in.) (lbs. force) (psi) FRACTURE TYPE 4 1 12/25/2004 7 6.00 28.26 4 2 01/15/2005 28 6.00 28.26 4 3 01/I5/2005 28 6.00 28.26 104330 3690 124700 4410 128330 4540 Average 4480 4 4 Hold Placement location: side lot, east half, north and south of machine room pad; 2' by 95' Paving, northwest dock floors and walls: Building XI, west section west Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared b~sed upon the specific samples provided for testing. We ~ssume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the ~itten approval of Rone Engineers, Ltd. 01SS Page 7 of 10 Report No.: 224828 Project No.: 049245 Client: Duke Realty Services, LP edge of machine pad; northwest dock door; floors 1 and 2 south from northwest corner of Building XI; doc door walls 3 and 4 south from northwest corner of Building XI. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in flail without the wri~en approval of Rone Engineers, Ltd. 01SS Page 8 of 10 Client: neers Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas Services: 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 224828 Project No.: 049245 Date of Service: 12/18/2004 Report Date: 01/17/2005 Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTILS, CTOR: Duke Construction CONCRETE SUPPLIER: SoutheFll Star PLAINT: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 3"-5" 4% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 12/18/2004 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: ll:45am BATCHTIME: ll:05am TEMPERATURE (F)-AIR 55 F CONCRETE: 65 F TRUC~; NO: 1097 YlOr~X NO: 761899 AIRCONTENT(%): 5.9 UNIT WEIGHT (pc0: NA OVEIL~.LL PLACEMENT LOCATION: See below SAMPLE LOCATION: 20' south, I 0' east from northwest REPORT OF TESTS comer, north &machine pad MEASURED SLUMP (inches) 5.0 Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi} TYPE 5 1 12/25/2004 7 6.00 28.26 127980 4530 Unbonded Cap 5 2 01/15/2005 28 6.00 28.26 157980 5590 Unbonded Cap 5 3 01/15/2005 28 6.00 28.26 151420 5350 Unbonded Cap Average 5470 5 4 Hold Placement location: Paving, northwest dock floors and walls: Building XI, west side lot, east half, north and south of machine room pad; 2' by 95' section west LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our leaers and reports are for the exclusive use of the clients to whom they ave addressed and shall not be reproduced except in ~all without the written approval of Rone Engineers, 01SS Page 9 of 10 Report No.: 224828 Project No.: 049245 Client: Duke Realty Services, LP edge of machine pad; northwest dock door; floors 1 and 2 south from northwest corner of Building XI; doc door walls 3 and 4 south from northwest corner of Building XI. Water added at site: Technician: Nathan Witherell Report Distribution: (1) Duke Realty Services, LP (1) Ext~anet (1) City of Coppell (1) City of Coppell 10 gallons Started: 6:30am Finished: 12:45pm K. Scott Watson, AET CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control Our letlers and repons are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the wrinen approval of Rone Engineers, Ltd. 015S Page 10 of 10