CONCRETE COMPRESSIVE STRENGTH TEST
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360 j
Dallas TX 75254 /
Freeport XI & XI~'
Coppell, Texas/'
Report No.: 224993
Project No.: 049245
Date of Service: 12/21/2004
Report Date: 01/03/2005
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
MEASURED
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
CONTRACTOR:
CONCRETE SUPPLIER: SoutheFll Star
PLANT: 27
SPECIFICATION REQUIREMENTS
4000 psi ~ 28
3" - 5"
3% - 5%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
Duke Constructio]~Da
MIX DESIGN I.D.: 7752
PLACEMENT OATE: 12/21/2004
WEATHER CONDITIONS: Clear/Cold
TIME SAMPLED: 5:00am BATCHTIME: 4:20am
TEMPERATURE (F)- AIR 51 F CONCRETE: 60 F
TRUCK NO: 1883 TICKET NO: 761930
AIRCONIENT(%): 4.2 UNIT WEIGHT (pcf): NA
O¥3ERALL PLACEMENT LOCATION:
Paving at north side of X11 and south side X1
SAMPLE LOCATION:
REPORT OF TESTS
30' west, 4' north of the
southeast comer
SLUMP
(inches)
5.5
Concrete Compressive Cylinder 6" x 12"
CYLINDER MAXIMUM COMPRESSIVE
MARKED DATE AGE DIAMETER AREA LOAD STRENGTIt FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE
1 1 12/28/2004 7 6.00 28.26 1 18880 4200 Unbonded Cap
1 2 01/18/2005 28 0.00 0.00 Unbonded Cap
1 3 01/18/2005 28 0.00 0.00 Unbonded Cap
1 4 Hold
LllvlITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing We assume no responsibiliiy for variation in quality
(composition, appearance, performance, ere) or any other feature of similar subject maiter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the wrinen approval of Rone Engineers, Ltd.
~ of 4
Client:
ineers
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.: 224993
Project No.: 049245
Date of Service: 12/21/2004
Report Date: 01/03/2005
Obtain samples of fi-esh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
MEASURED
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: Southern Star
PLANT: 27
SPECIFICATION REQUIREMENTS
4000 psi @ 28 Days
3" - 5"
3% - 5%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 12/21/2004
WEATHER CONDITIONS: Clear/Cold
TIME SAMPLED: 6:30am BATCHT1ME: 5:35an2
TEMPERATURE (F) - AIR 5 1 F CONCRETE: 60 F
TRVCKNO: 1020 TIC}tETNO: 761941
AIR CONTENT {%): 3.9 LrNIT WEIGHT (pci): NA
OVERALL PLACEMEN"F LOCATION:
Paving at north side of X11 and south side XI
SAMPLE LOCATION:
REPORT OF TESTS
200' west, 20' north of the
southeast comer
Concrete Compressive Cylinder 6" x 12"
SLUMP
(inches)
4.5
CYLENDER MAXIMUM COMPRESSIVE
MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE
2 1 12/28/2004 7 6.00 28.26
2 2 01/18/2005 28 0.00 0.00
2 3 01/18/2005 28 0.00 0.00
2 4 Hold
114250 4040 Unbonded Cap
Water added at site: 5 gallons
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc) or any other feature of simdar subject matter prowded by persons or conditions over which we have no control Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in f~ll without the written approval of Rone Engineers, Ltd.
Pace 2 of 4
Client:
ineers
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Services:
Report No.: 224993
Project No.: 049245
Date of Service: 12/21/2004
Report Date: 01/03/2005
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive slrength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
MEASURED
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: Southern Star
PL3dNT: 27
SPECIFICATION REQUIREMENTS
4000 psi @ 28 Days
3" - 5"
3% - 5%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 12/21/2004
WEATHER CONDITIONS: Clear/Cold
TIME SAMPLED: 8:00alrl BATCHThME: 6:53am
TEMPERATURE (F) - AIR 52 F CONCRETE: 61 F
muc~ NO: 1020 TICKET NO: 761949
AIR CONTENT (%): 4.0 UNIT WEIGHT (peri: NA
OVERALL PLACEMENT LOCATION:
Paving at north side of X11 and south side X1
SLUMP
(inches)
4.25
SAMPLE LOCATION:
REPORT OF TESTS
· ' 'x12'
Concrete Compress ye C~I nder 6
75' west, 37' north of the
southeast comer
CYLINDER MAXIMUM COMPRESSIVE
MARKED DATE AGE DL~METER AREA LOAD STRENGTH FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE
3 1 12/28/2004 7 6.00 28.26 111450 3940 Unbonded Cap
3 2 01/18/2005 28 0.00 0.00 Unbonded Cap
3 3 01/18/2005 28 0.00 0.00 Unbonded Cap
3 4 Hold
L!MITATIONS: The test results presented herein were prepared b~sed upon the specffic samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc) or any other feature of similar subject matter provided by persons or conditions over which we have no control Our letters and
reports are for the exclusive use of the clients to whom they arc addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
Paee 3 of 4
Client:
ineers
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Services:
Report No.: 224993
Project No.: 049245
Date of Service: 12/21/2004
Report Date: 01/03/2005
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
MEASURED
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: Southern Star
PLANT: 27
SPECIFICATION REQUIREMENTS
4000 psi ~ 28 Days
3"- $"
3% - 5%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 12/21/2004
WEATHER CONDITIONS: Clear/Cold
TIME SAMPLED: 9:15am BATCHTIME: 8:26am
TEMPERATURE (F) - AIR 54 F CONCRETE: 62
tRUCK NO: 931 TICKET NO: 761959
AIR CONTENT (%): 4.1 UNITWE1GHT(pcf): NA
OVERALL PLACEMENT LOCATION:
Paving at north side of X11 and south side X1
SAMPLE LOCATION:
REPORT OF TESTS
13' west. 32' north of the
southeast comer
SLUMP
(inches)
5.0
Concrete Compressive Cylinder 6" x 12"
CYLINDER
NLatRKED DATE AGE DIAMETER AREA
SET NO. TESTED (days) (inches) (sq.in.)
4 1 12/28/2004 7 6.00 28.26
4 2 01/18/2005 28 0.00
4 3 01/18/2005 28 0.00
4 4 Hold
Technician: Scott Mitchell
Report Distribution:
(1) Duke Realty Services, LP
(1) Extranet
(1) City of Coppell
(1) City of Coppell
Started: 3:15am
MAXIMUM COMPRESSIVE
LOAD STRENGTH FRACTURE
(lbs. force) (psi) TYPE
108210 3830 Unbonded Cap
0.00 Unbonded Cap
0.00 Unbonded Cap
Finished: l:I5pm
'~ ~( ~cott-Wa'i'son,
CMT Operations Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in qualiiy
(composition, appearance, performance, etc) or any other feature of simila~ subject matter provided by persons or conditions over which we have no con~-ol. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval ofRone Engineem, Ltd.