Loading...
ST9302-CS010703TEXAS DEPARTMENT OF LICENSING AND REGULATION Code Review and Inspections - ARCHITECTURAL BARRIERS P.O. Box 12157 Austin, '~exas 78711 (512)463-3211 (877)278-0999 FAX(512)475-2886 Email Address: techinfo.ab~,license, state, b(.us Internet Address: www. license, state.tx, us JEFF JAMES KIMLEY HORN & ASSOC INC JEFF JAMES 801 CHERRY ST UNIT #11 FORT WORTH, TX 76102 Re: COPPELL SANDY LAKE RD PAVING/DRIA/~AGE WATER SYSTEM-COPPELL SANDY LAKE RD COPPELL, TX 75019 JUL-03-2001 EABPRJA1008798 PLANS, SIGNED AND SEALED 06/29/98; AND SPECIFICATIONS Dear MR. JAMES Enclosed are the results of the plan review completed on the referenced project. Identified on the worksheet(s) are areas of nonconformance with accessibility standards adopted by the Texas Department of Licensing and Regulation for purposes of ensuring compliance with Article 9102, Texas civil Statutes. Although nonconforming items have been noted, the referenced project will be eligible for approval if constructed accordin~ to the documents reviewed and as noted on the worksheet(s). Items which are the responsibility of the owner should be referred to the appropriate person for action. This determination does not address applicability of the Americans with Disabilities Act (ADA), (P. L. 101-336), or any other state, local, or federal requirement. For information on the ADA, call the ADA Hotline, (800)949-4232 Or the United States Department of Justice at (202)514-0301. An inspection will be conducted Within one year of the completion date. The buildin~ owner will be contacted to arrange the inspection. Please reference the EABPRJ number in all future correspondence pertaining to this project. :DKJ A!st~ Headquai-ter~:~.0. Thompson State Office Building - 920 Colorado - Austin, Texas 78701 TEXAS DEPARTMENT OF LICENSING AND REGULATION PL~/NS AND SPECIFICATIONS REVIEW WORKSHEET Article 9102, T.C.S. PROJECT NO.: EABPRJA1008798 REVIEW : E~tB2001048169R PAGE: 1 PROJECT: FACILITY: OWNER: A~CHITECT: REVIEWER: PAVING/DRI~-NAGE WATER SYSTEMoCOPPELL COPPELL SD/~-DY ~ RD CITY OF COPPELL KIMLEY HOP~N & ASSOC INC JD/qNS, DEBORA~q K DATE: 07/02/01 4 ACCESSIBLE ELEMENTS AND SPACES: TECHNICAL REQUIREMENTS **PROJECT DESCRIPTION: CONSTRUCTION OF REINFORCED CONCRETE PAVING, CONCRETE DRAINAGE CHAArNEL, STOPd4 DR3%IN, ~ WATER SYSTEM IMPROVEMENTS THE SCOPE OF WORK ALSO INCLUDES SIDEWD~LKS AiTD CL~RB RAMPS. **APPLICATION: 4.1.2 SITES ~ EXTERIOR FACILITIES: NEW CONSTRUCTION ALL "COMPLIANCE REQUIRED" ITEMS MUST BE CORRECTED PRIOR TO INSPECTION TO BE APPROVED. ITEMS NOTED AS "UNACCEPTABLE", WH. ICH D~E BEYOND THE SCOPE OF THE ENGINEER, SHOULD BE FORWARDED TO THE CITY OF COPPELL FOR ACTION. CONSTRUCTION DOCLrMENTS CANNOT BE CONSIDERED APPROVED UNTIL ALL "UNACCEPTABLE" ITEMS ARE RESOLVED. UNACCEPTABLE 4.3 ACCESSIBLE ROUTE 4.3.7 Slope **NOTE: TO comply with 4.3.7, the slope of new sidewalks cannot exceed 5% in the direction of travel. According to plans, (ie. sheet 54), the slope exceeds 5% in some areas. SPECIFICATIONS REVIEW WORKSHEET ALticle,9102, T.C.S. PROJECT NO.: E~-BPRJA1008798 REVIEW : EA]32001048169R PAGE: 2 PROJECT: FACILITY: REVIEWER: PAVING/DRI~AGE WATER SYSTEM-COPPELL COPPELL S~2VDY LA/<E RD JAHNS, DEBORAH K DATE: 07/02/01 NOT NOTED UNACCEPTABLE NOT NOTED UNACCEPT~BLE *COMPLIANCE REQUIRED WITH 4.3.7 4.4 PROTRLrDING OBJECTS **NOTE: Ensure that trees, overhead signage, utility boxes, fire hydrants, etc. do not protrude into the accessible route. 4.5 GROUND ~2qD FLOOR SLrRFACES 4.5.1 General **NOTE: Unable to verify that the ground surface of the accessible route that crosses existing streets is in compliance with the requirements of 4.5. *COMPLIANCE REQUIRED WITH 4.5 4.6 PARKING AND PASSENGER LOADING ZONES 4.7 CURB RAMPS 4.7.2 Slope **NOTE: Insufficient information provided to verify that the slope of the adjoining gutters and road surface directly adjacent to new curb ramps is no more than 2%. *COMPLIANCE REQUIRED WITH 4.7.2 4.7.4 Surface **NOTE: Insufficient information provided on the standard detail sheet to verify that new curb ramps will have a texture that does not accummulate water and is detectable under foot, and a color that significantly contrasts with the adjoining sidewalk and street. *COMPLIANCE REQUIRED WITH 4.7.4 4.7.10 Diagonal Curb Ramps **NOTE: To comply with 4.7.10, diagonal curb ramps with flared sides must have at least a 24" long segment of straight curb on each side of the curb ramp. According to the typical detail sheet, the straight segment of curb is not provided on diagonal curb ramps. · FL~N~ ~ SPECIFICATIONS REVIEW WORKSHEET ArTicle'9102, PROJECT NO.: EABPRJA1008798 REVIEW : EAB2001048169R PAGE: 3 PROJECT: FACILITY: REVIEWER: PAVING/DRIANAGE WATER SYSTEM-COPPELL COPPELL S~-N-DY IJYKE RD JD~qNS, DEBORAH K DATE: 07/02/01 NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED UNACCEPTABLE **NOTE: *COMPLIAi~CE REQUIRED WITH 4.7.10 TO comply with 4.7.10, the straight segment of curb ramp required for diagonal curb ramps must be located within the marked crossings. According to plans, curb ramps at marked crossings do not comply with this requirement. *COMPLIANCE REQUIRED WITH 4.7~10 4.8 RAMPS 4.9 STAIRS 4.10 ELEVATORS 4.11 PI2%TFORM LIFTS (Wheelchair Lifts) 4.12 WINDOWS 4.13 DOORS 4.14 ENTRANCES 4.15 DRINKING FOL~NTAINS ~ WATER COOLERS 4.16 WATER CLOSETS 4.17 TOILET STALLS 4.18 L~RINALS 4.19 LAVATORIES D~ND MIRRORS 4.20 BATHTUBS 4.21 SHOWER STALLS 4.22 TOILET ROOMS 4.23 BATHROOMS, BATHING FACILITIES, ~ SHOWER ROOMS 4.24 SINKS 4.25 STORAGE 4.26 ~ULN-DR3~ILS, GP~AB B~S, ~ TUB D_ND SHOWER SEATS 4.27 CON~fROLS AND OPERATING MECH3%NISMS ~LAN~ A~rD SPECIFICATIONS REVIEW WORKSHEET ~Aftic. ie'9102, T.C.S. PROJECT NO.: ED~BPRJA1008798 REVIEW : EA]B2001048169R PAGE: 4 PROJECT: FACILITY: REVIEWER: PAVING/DRI;kNAGE WATER SYSTEM-COPPELL COPPELL S~dkqDY I2%KE PdD JAPANS, DEBORZ~q K DATE: 07/02/01 NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED NOT NOTED 4.27.2 Clear Floor Space **NOTE: To comply with 4.27.3, at least 30" x 48" of clear and level floor space must be centered on the pedestrian crosswalk controls. Insufficient information is provided to verify compliance. *COMPLIANCE REQUIRED WITH 4.27.2 4.27.3 Height **NOTE: TO comply with 4.27.3, pedestrian crosswalk controls must be mounted no higher than 54" AFF. Insufficient information is provided to verify compliance *COMPLIANCE REQUIRED WITH 4.27.3 4.28 ALARMS 4.29 DETECT;YBLE W~INGS 4.30 SIGNAGE 4.31 TELEPHONES 4.32 FIXED OR BUILT-IN SEATING AND TABLES 4.33 ASSEMBLY AREAS 4.34 AUTOMATED TELLER MACHI~rES 4.35 DRESSING AND FITTING ROOMS 5 RESTAURANTS, CAFETERIAS, SNACK BARS, AND VENDING AREAS 5.1 GENER3~L 5.2 COUNTERS D~ND BARS 5.3 ACCESS AISLES 5.4 DINING AREAS 5.5 FOOD SERVICE LINES 5.6 TABLEWARE AND CONDIMENT AREAS PLANS AND SPECIFICATIONS REVIEW WORKSHEET A~ticle' 9102, T.C.S. PROJECT NO.: EABPRJA1008798 REVIEW : EAB2001048169R PAGE: 5 PROJECT: FACILITY: REVIEWER: PAVING/DRIA/~AGE WATER SYSTEM-COPPELL COPPELL SANDY LAKE RD JA}INS, DEBORAH K DATE: 07/02/01 NOT NOTED NOT NOTED NOT NOTED NOT NOTED 5.7 RAISED PLATFORMS 5.8 VENDING MACHINES AND OTHER EQUIPMENT 5.9 QUIET AREAS (Reserved) 6 MEDICAL C/LRE FACILITIES 6.1 GENER3LL 6.2 ENTP, ANCES 6.3 PATIENT BEDROOMS 6.4 PATIENT TOILET ROOMS 6.5 SIZE OF AREAS OF RESCLrE ASSISTANCE 6.6 INFORMATION COUNTERS A/TD NLrRSES STATIONS 7 BUSINESS A_ND MERCANTILE 7.1 GENER3%L 7.2 SALES AND SERVICE COUNTERS, TELLER WINDOWS, INFORPL~TION COUNTERS 7.3 CHECK-OUT AISLES 7.4 SECL~RITY BOLI~DS ~ ~TIRNSTILES 8 LIBRARIES 8.1 GENER3LL 8.2 READING AND STUDY AREAS 8.3 CHECK-OUT AREAS 8.4 CARD CATALOGS AND MAGAZINE DISPLAYS 8.5 STACKS 9 ACCESSIBLE TRANSIENT LODGING 9.1 HOTELS, MOTELS, INlqS, BOARDING HOUSES, DORMITORIES, RESORTS, ETC 9.2 REQUIREMENTS FOR ACCESSIBLE UNITS, SLEEPING ROOMS ;LNID SUITES 9.3 VISUAL ALAPJ~S, NOTIFICATION DEVICES AND TELEPHONES D~S ~ SPECIFICATIONS REVIEW WORKSHEET Article 9102, T.C.S. PROJECT NO.: EA~PRJA1008798 REVIEW : EAB2001048169R PAGE: 6 PROJECT: FACILITY: REVIEWER: PAVING/DRIANAGE WATER SYSTEM-COPPELL CORPELL SANDy LAKE RD JARNS, DEBOP3%H K DATE: 07/02/01 NOT NOTED 9.4 OTHER SLEEPING ROOMS ~ SUITES 9.5 SHELTERS, HALFWAY HOUSES, GROUP HOMES, OTHER ESTABLISHMENTS. 10 TRANSPORTATION FACILITIES **NOTE: If bus stops are provided, compliance with section 10 is required. 10.1 GENER3%L 10.2 BUS STOPS AND TERMIN;kLS 10.3 FIXED FACILITIES AND STATIONS 10.4 AIRPORTS 10.5 BOAT AND FERRY DOCKS (Reserved)