Loading...
WA0001-CS000405HENLEY JOHNSTON & ASSOCIATES, INC. engineering geosclence ~nsullan[s Transmittal Date: 5 ADril 2000 To: SF?.'h=Ek, Jacobs & FiD3clea Attn: liT. ,~ry C. Hendricks, PE Project: CDp;_~ell 1.5 M. G. ~le,~t~l Tank Gentlemen: Henley-Johnston & Assoc., Inc. transmits herewith the Paint I_nsiEtion Re.oort i~: 16939-0 (3/15/00-3/16/00) following: Comments: cc; Larry Davis, City of Co?pall Sincerely yours, Herbert C. Cro~ler telephone (214) 94Z.3808 fax (214) 943.7645 Henley-Johnston & Assoc., Project No. 7] 5] 235 Morgan Ave.. Dallas. Tcxas 75203 Inc. · . 4305 Glenwood Ct. Granbury, TX 76049 Client Henley Johnston & Associates Attn: Herb Crowder Contractor Advantage ABRASIVE MATERIAL Abrasive Type: Bulk blasting sand Recycled: No Air Quality Good Equipment Project Inspector Sullair 1300 compressor; three (3) blast hoses COATINL ,NSPECTION REPORT Date 03-15-00 Report 16939-0 Page. 1 of I *03-16-00 Coppell 1.5 M.G. Elevated Tank Coppell, Texas Cindy Holmes, Certified Coating Inspector SURFACE PREPARATION Standard Specified SSPC-SP 10 Standard Achieved SSPC-SP 10 Profile Reading Average 4.03 mils ENVIRONMENTAL CONDITIONS COATING MATERIAL Date 3/15/00 3/16/00 3/16/00 Material used Carboguard 561 Time 7:45 a.m. 11:30 a.m. 2:00 p.m. Batch No. Part A 9H0716M Dry Bulb 68 69 81 Part B 9H0656M Wet Bulb 49 6O 57 Part C N/A Humidity · 20% 59% 20 Thinner #10 OA11455 Dew Point 26 54 34 Application method Airless spray (517 tip) Surface Temp 64 70 73 Color - 1898 White Wind Interior ENE 10 Interior DRY FILM THICKNESS Area Number of Low High Mean Comments Readings DFT gage used Additional Information: 03-15-00 Contractor requested a preliminary inspection of the blast prior to scheduled inspection on 03-16-00. Surfaces blasted so far include floor and up about four (4) feet on bowl. Some areas in the ceiling are blasted also. Areas blasted up till now have some existing coatings still on the surface. These areas need to be blasted again. A Munter's 4500 dehumidifier is on site and running. The interior temperatures reflect this. Blasted areas do not appear to have any rust bloom present. 03-16-00 Areas presented for inspection today includes the ceiling and rafters on the south half of the tank. Areas acceptable per SSPC-SP10 include ceiling from center rail out to about five (5) feet above wall painter's rail. Areas on riser pipe and around roof hatch need additional blast cleaning and will not be coated today. Prior to the airless spray application of Carboguard 561 blasted areas were blown clean with blast hose air. Airless spray application started at 3:00 p.m. This report is for the exclusive use of our client and shall not be modified or repredueed without written approval of said client