SS9901-LR041207Client: Project: GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080 Concrete Compression Test Report City of Coppell Report Distribution: (1) City of Coppell DeForest Rd. Lift Station Imp. Force Main Line "D" TMI Report No.: 74792-008 Report Date: 12/07/2004 Specification~s Strength 4200 psi @ 28 Days Placement Date Slump 3 in min 5 in max Sampled By Air Content 3 % min 6 % max Weather Concrete Temperature n/a Supplier/Mix Ambient Temperature n/a Air Content Method '[gst Data 11/01/2004 Mohammed A. Kashem Cloudy Custom Crete/CC1065A ASTM C-231-B Ticket Number: 314941 Time Batched: 12:50 pm Time Sampled: 1:15 pm Slump: 4 in Air Content: 3.8 % Unit Weight: n/a Concrete Temperature: 74° F Ambient Temperature: 72° F Yardage (c.y.): n/a Placement Location: Manhole base 30" force main Sample Location: At Staiton 27+00 Age Max Load Area Streng~ Fracture Set# Cyl~der Test Date (days) (lbs. ~rce) (sq.in.) (ps~ Type 1 11010401 11/08/2004 7 94180 28.27 3330 unbonded cap 1 11010402 11/29/2004 28 144400 28.27 5110 unbonded cap 1 11010403 11/29/2004 28 144640 28.27 5120 unbonded cap 1 11010404 Hold 28 day average 5120 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. TERRA-MAR, INC. The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. 0[ssD Page Iofl Client: Project: GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORTWORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080 Concrete Compression Test Report City of Coppell Report Distribution: (1) City of Coppell DeForest Rd. Lift Station Imp, Force Main Line "D" TMI Report No.: 74792-008 Report Date: 12/07/2004 Strength 4200 psi @ 28 Days Slump 3 in min 5 in max Air Content 3 % min 6 % max Concrete Temperature n/a Ambient Temperature n/a .SPecifi. cations .......... Test Data Placement Date Sampled By Weather SuppliedMix Air Content Method 11/01/2004 Mohammed A. Kashem Cloudy Custom Crete/CC1065A ASTM C-231-B Ticket Number: 314941 Time Batched: 12:50 pm Time Sampled: 1:15 pm Slump: 4 in Air Content: 3.8 % Unit Weight: n/a Concrete Temperature: 74" F Ambient Temperature: 72° F Yardage (c.y.): n/a Placement Location: Manhole base 30" force main Sample Location: At Staiton 27+00 Age Max Load Area Strength Fracture Set# Cyl~der TestDate (days) Obs. ~rce) (sq.in.) (ps~ Type 1 11010401 11/08/2004 7 94180 28.27 3330 unbonded cap 1 11010402 11/29/2004 28 144400 28.27 5110 unbonded cap 1 11010403 11/29/2004 28 144640 28.27 5120 unbonded cap 1 11010404 Hold 28 day average 5120 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. TERRA-MAR, INC. The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any pad therein, is strictly prohibited without the express written consent of TMI. mssp Page Iofl