Freeport NIP(8.0)-LR050208Client: ineers Duke Realty Services, LP Mr. Brian S~aley 5495 Belt Line Rd~, Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 227103 Project No.: 049245 Date of Service: 01/29/2005 Report Date: 02/08/2005 Services: Oblain samples of flesh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. STRENGTH: SLUMP (in): AIR (%): TEST METHOD: co~axACrOm Duke Construction CONCRETE SUPPLIER: Southern Star PLANT: 27 SPECI]ZiCATION REQUH~£MENTS 4000 psi ~ 28 Days 3" - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C~ 1231 ASTM C-39 PROJECT DATA MIX DESIGN LO.: 7752 PI~a-CEMENT DATE: 01/29/2005 WEATHER commons: Cloudy TIME SAMPLED: 8.' 15arfl BATCH TIME: 7155am TEMPERATURE (El - AIR 49 g CONCRETE: 63 TaVCKNO: 923 TICKrTNO: 782295 AIR CONTENT (%): 4.8 UNIT WEIGHT (pet): NA OVERALL PLACEMENT LOCATION: Paving, entryway lff north, 45' east f~om northeast comer of Build~ng SAMPLE LOCATION: 25' east. 25' south from northe~t REPORT OF TESTS co~.~r of Building 11 MEASURED SLUMP (inch~s) 5.25 Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 1 1 02/05/2005 7 6.00 28.26 134300 ~ 4750 Unbonded Cap 1 2 02/26/2005 28 0.00 0.00 Unbonded Cap 1 3 02/26/2005 28 0.00 0.00 Unbonded Cap 1 4 Hold LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject major provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clienls to whom they are addressed and shall not be reproduced except in thll without the written approval of Rone Engineers, Ltd. OISS Page I of 3 Rom Client: ineers Duke Realty Services, LP Mr. Brian Slraley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII CoppeIl, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 227103 Project No.: 049245 Date of Service: 01/29/2005 Report Date: 02/08/2005 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACrOR: Duke Construction CONCRETE SUPPLIER: Southerll Star PLA~T: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 3" - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C- 1231 ASTM C-39 MIX DESIGN LD.: 7752 PLACEMENT DATE: 01/29/2005 WEATHER CONDITIONS: Cloudy TIME SAMPLED: 9:30am BATCH TIME: 9:0511311 TEMPERATURE (F) - AIR 52 F CONCRETE: 65 F MUCKNO: 1827 T~CRETNO: 782307 AIR CONTENT (%): 5.3 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Paving, entryway 10' north. 45' east from no,boost comer of Building 11 SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 15' north, 20' east from northeast comer of Building 11 MF~.SURED SLUMP (inches) 5.0 CYLINDER MARI~ED DATE AGE SET NO. TESTED (days) 2 1 02/05/2005 7 2 2 02/26/2005 28 2 3 02/26/2005 28 2 4 Hold MAXIMUM COMPRESSIVE DIAMETER AREA LOAD STRENGTH FRACTURE (inches) (sq.in.) (lbs. force) (psi) TYPE 6.00 28.26 146470 5180 Unbonded Cap 0.00 0.00 Unbonded Cap 0.00 0.00 Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (compost on, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers. Ltd. 01SS Page 2 of 3 Client: Jneers Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. t50, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 227103 Project No.: 049245 Date of Service: 01/29/2005 Report Date: 02/08/2005 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Duke Construction CONCRETE SUPPLIER: Southern Stat PLANT: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 3" - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 · ASTM C-1064 ASTM C- 1231 ASTM C-39 9.1.2 MIX DESIGN LD.: 7752 PLACEMENT DATE: 01/29/2005 WEATHER CONDmONS: Cloudy TINIESAMPLED: 10:20am BATCHTEME: 9:55~T1 TEMPERATURE (F)- AIR 52 F CONCRETE: 66 · RUC~ NO: 1827 TICRET NO: 782315 AIR CONTENT (%): 5.1 UNITWE1GHT (~0: NA OVERALL PLACEMENT LOCATION: Paving en~3,way 10' north. 45~ east from no~hcas~ corner of Building SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 35' eas~ 95' north from northeast comer of Building 11 MEASURED SLUMP (inches) 5.5 CYLINDER MARKED DATE AGE DIAMETER SET NO. TESTED (days) (inches) 3 1 02/05/2005 7 6.00 3 2 02/26/2005 28 0.00 3 3 02/26/2005 28 0.00 3 4 Hold Technician: Jeremy Watts Report Distribution: (1) Duke Readty Services, LP (1) Extranet (1) City of Coppell (1) City of Coppell Started: 8:00arn ~ COMPRESSIVE AREA LOAD STRENGTH (sq.in.) (lbs. force) (psi) 28.26 113450 [ 4010 Unbonded Cap 0.00 0.00 Finished: l l:30am Unbonded Cap Unbonded Cap K. Scott Watson, AET CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 0ISS Page 3 of 3