Freeport NIP(8.0)-LR050203ineers 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport 33 & XII Coppell, Texas Report No.: 226913 Project No.: 049245 Date of Service: 01/26/2005 Report Date: 02/03/2005 Services: Obtain samples of flesh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Duke Construction CONCRETE SUPPLIER: Southerll Stat PLnNT: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 4" - 6" 3%-5% ASTM C-172 ASTM C-31 ASTM C- 143 ASTM C-231 ASTM C-1064 ASTM C- 1231 ASTM C-39 MIX DESIGN I.D.: 7752 MEASURED SLUMP PLACEMENT DATE: 01/26/2005 0aches) WEATHER CONDITIONS: Clear 5.25 TIME SAMPLED: 3:30am BATCH TIME: 2:55am TEMPERATURE (F) - AIR 46 F CONCRETE: 66 F TRUCKNO: 1827 TICKET NO: 782207 AIR CONTENT (%): 4.5 UNITWEIGHT (pet): NA OVERALL PLACEMENT LOCATION: Paving, south side Building X] drive around, parking southwest comer of Building XI (bloekouts), east side Building XI SAMPLE LOCATION: REPORT OF TESTS 120' east, 20' north fi'om southwest ConcreU: Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 1 I 02/02/2005 7 6.00 28.26 111090 /~30 Unbonded Cap 1 2 02/23/2005 28 0.00 0.00 Unbonded Cap 1 3 02/23/2005 28 0.00 0.00 Unbonded Cap 1 4 Hold LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or zay other feature of similox subject mat~er provided by persons or conditions over which we have no control. Our leRers and reports ar~ for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the wriRen approval of Rone Engineers, Ltd. 01SS Page 1 of 5 Client: ineers Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 226913 Project No.: 049245 Date of Service: 01/26/2005 Report Date: 02/03/2005 Services: Obtain samples of flesh concrete at the placement locations, perform required field testing cast compressive slrength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTP. ACrom Duke Construction CONCRETE SUPPLIER: Southern Star pLa~cr: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 4"-6" 3% - 5% ASTM C- 172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MIX DESIGN I.D.: 7752 MEASURED SLUMP PIACEMENT DATE: 01/26/2005 (inches) WEATHER CONDITIONS: Clear 6.0 TIME SAMPLED: 5:30am BATCHTIME: 4:10am TEMPERATURE (F} * AIR 46 F CONCRETE: 64 v MUCK NO: 1840 TICRET NO: 782216 AIR cowr~NT (%): 4.9 UNrr WEIGHT (poi): NA OVERALL PLACEMENT LOCATION: Paving, south side Building XI drive around, parking southwest comer of Building XI (blockoms), east side Building XI SAMELE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 100' west, 30' north from southeast comer CYLINDER MARKED DATE AGE SET NO. TESTED (days) MAXIMUM COMPRESSIVE DIAMETER AREA LOAD STRENGTH FRACTURE (inches) (sq.in.) (lbs. force) (psi) TYPE 2 1 02/02/2005 7 2 2 02/23/2005 28 2 3 02/23/2005 28 2 4 Hold Water added at site: 5 gallons 6.00 28.26 97450 3450 Unbonded Cap 0.00 0.00 Unbonded Cap 0.00 0.00 Unbonded Cap LIMITATIONS: The test results presented hemm were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, p~fformance, etc.) or any other feature of similar subject matter provided by persons or conditions over wlfich we have no control. Our letters and reports are for the exclusive use of the clients to whom they arc addressed and shall not be reproduced except in full without the written appmvat of Rone Engineers, Ltd. 01SS Page 2 of 5 Client: Duke Realty Services, LP Mr. Brian SU'aley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 226913 Project No.: 049245 Date of Service: 01/26/2005 Report Date: 02/03/2005 Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Duke Construction CONCRETE SUPPLIER: Southern Star eLAN'r: 27 SPECliqCATION REQUIREMENTS 4000 psi ~ 28 Days 4" - 6" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MIX DESIGN I.D.: 7752 MEASURED SLUMP PLACEMENT DATE: 01/26/2005 (inches) WEATHER CONDITIONS: Clear 5.75 TIME SAMPLED: 7:00am BATCH TIME: 6:15arll T~MPEg~TVRE (F)- Am 45 F CONCRETe: 66 TRVCKNO: 923 TIC~T NO: 782225 AIR CONTENT (%): 4.8 UNITWEIGHT(pc0: NA OVERALL PLACEMENT LOCATION: Paving, south side Building XI drive around, parking southwest comer of Building X] (blockouts), east side Building XI SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 30' wesL 40' north from southeast CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 3 1 02/02/2005 7 6.00 28.26 106250 ~3760 Unbonded Cap 3 2 02/23/2005 28 0.00 0.00 Unbonded Cap 3 3 02/23/2005 28 0.00 0.00 Unbonded Cap 3 4 Hold Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject mater provided by persons or conditions over which we have no control. Our lettors and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01SS PaRe 3 of 5 Client: Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 ;ers Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 226913 Project No.: 049245 Date of Service: 01/26/2005 Report Date: 02/03/2005 Obtain samples of besh concre~ at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMI' (in): AIR (%): TEST METHOD: coNTancrog: Duke Construction CONCRETE SUPPLIER: Southern Star PiqUeT: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 4" - 6" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-123! ASTM C-39 MIX DESIGN I.D.: 7752 MEASURED SLUMP PLACEMENT DATE: 01/26/2005 0nches) ~VEATHER CONDITIONS: Clear 7.0 TIME SAMPLED: 9: ] 5arll BATCH TIME: 8:50aii1 TEMPERATURE (F) - AIR 54 F CONCRETE: 67 E mUCK NO: 8 ~C~TNO: 782238 AIR CONTENT (%): 5.0 UNIT WEIGHT (pcI): NA OVERALL PI&CEMENT LOCATION: Paving, south side Building XI drive around, peri(mc southwest comer of Building XI. (blockouts), e~st side Building XI SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 60' east. 25' north bom southwest comer CYLINDER MARKED DATE AGE SET NO. TESTED (days) MAXIMUM COMPRESSIVE DIAMETER AREA LOAD STRENGTH FRACTURE (inches) (sq.in.) (Ibg force) (psi) TYPE 4 1 02/02/2005 7 4 2 02/23/2005 28 4 3 02/23/2005 28 4 4 Hold Water added at site: 15 gallons 6.00 28.26 97470 3450 Unbonded Cap 0.00 0.00 UnbondedCap 0.00 0.00 Unbonded Cap LIMITATIONS: The test results presented herein wen prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject ma'aer provided by persons or conditions over which we have no contsol. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in fulI without the vaitten approval of Rone Engineers, Ltd. 01SS Page 4 of 5 Client: I neers Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., StP 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, StP. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 226913 Project No.: 049245 Date of Service: 01/26/2005 Report Date: 02/03/2005 Services: Obtain samples of fi'esh concrete at the placement locations, perform required field testing ca~t compressive s'a'cngth samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Duke Construction CONCRETE SUPPLIER: Southern Star m~.~T: 27 SPECIFICATION REQUIREMENTS 4000 psi @ 28 Days 4" - 6" 3%-5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C- 1064 ASTM C- 1231 ASTM C-39 MIX DESIGN I.D.: 7752 MEASURED SLUMP PLACE~t~T DATE: 01/26/2005 (inches) WEATHER CONDITIONS: Clear 5.5 TIME SAMPLED: ll:15am BATCHTINIE: 10:03am TEMPERATURE (F)- AIR 64 F CONCRETE: 68 F TRUCK NO: 1015 TICRET NO: 782248 AIR CONTENT (%): 5.0 UNIT WEIGHT (pcf~: NA OVERALL PLACEMENT LOCATION: Paving. south side Building X1 drive around, parking southwest come~ of Building X1 (blockouts), east side Building XI SAMPLE LOCATION: 30' west, 15' south fi'om northeast REPORT OF TESTS ~o~er Concrete Compressive Cylinder 6" x 12" CYLENDER MARKED DATE SET NO. TESTED 5 1 02/02/2005 AGE DIAMETER (days) Onches) MAXIMUM COMPRESSIVE AREA LOAD STRENGTH FRACTURE (sq.in.) (lbs. force) ~[~si) TYPE 28.26 124150 [4390 Unbonded Cap 7 6.00 5 2 02/23/2005 5 3 02/23/2005 5 4 Hold Technician: Nathan Witherell Report Distribution: (I) Duke Realty Services, LP (1) Extran~t (1) City of Coppell (1) City of Copp¢ll 28 0.00 28 0.00 Startea: 2:30am 0.00 Unbonded Cap 0.00 Unbonded Cap Finished: ]:00pm K. Scott Watson, AET CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no con,roi. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01SS Page 5 of 5