SS9901-LR040819 GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW I 7050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(g72) 488-8080 Client: Project: In-Place Soil Moisture/Density Tests by Nuclear Method Report Distribution: (1) City of Coppell City of Coppell DeForest Rd. Lift Station Imp. Force Main Line "D" D TMI Report No.: 74792-004 Report Date: 08/19/2004 Specifications Percent Compaction: +95% min +100% max Moisture Content: opt +0% to +4% Test Data Date Tested: 08/11/2004 Technician: Martin Silva Cu~e No, Optimum Maximum Dry Test Method Material Description Moisture % Density pcf 760 Gray Clay w/Traces of Asphalt, Shale, & Gravel 15.5 109.0 L i j n,place Test Resu ts Test Elevation Ref. Probe Percent Wet Density Dry Density Percent No or Lift Location Curve Depth Moisture (pcf} (pcf) Density ASTM D-696-A Force Main Line D 3.0 1st lift at Station 20+75 780 6" 15.9 122.0 105.3 96.6 4.0 3rd lift at Station 20+75 780 6" 16.2 121.1 104.2 95.6 5.0 4th lift at Station 20+75 780 6" 16.5 122.1 104.8 96.1 6.0 6th lift at Station 20+75 780 6" 17.1 124.4 106.2 97.4 Test results on this report meet project specification. Test Method(s): ASTM D-2922, ASTM D-3017 Gauge: Troxler Gauge SN: 00219 Std. Density Count: 6695 Std. Moisture ount: 1133 TERRA-MAR, INC. Mike Fuller Project Manager The results presented in this report pertain on[y to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is stdctly prohibited without the express written consent of TMI. 07BHC Page ] of I ~ ?--'"~ Client: Project: GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Able$ Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080 In-Place Soil Moisture/Density Tests by Nuclear Method City of Coppell Report Distribution: (1) City of Coppell DeForest Rd. Lift Station Imp. Force Main Line "D" TMIReport No.: 74792-002 Report Date: 08/19/2004 specincations Percent Compaction: +95% rain +100% max Moisture Content: opt -3% to +3% Teat Data Date Tested: 07/26/2004 Technician: Robert Plummet Optimum Maximum Dry Curve No. Test Method Matedal Description Moisture % Density pcf 780 ASTM D-698-A Gray Clay w/Traces of Asphalt, Shale, & Gravel 15.5 109.0 Test Elevation Ref. Probe Percent Wet Density Dry Density Percent No or Lift Location Curve Depth Moisture (pc0 (pc'f) Density Water Line 1.0 -1' BEG at Cedar Street 780 6" 15.9 125.9 108.6 99.6 2.0 -1' BEG at Cedar Street 780 6" 15.2 124.2 107.8 98.9 Test results on this report meet project specification. Test Method(s): ASTM D-2922, ASTM D-3017 Gauge: Trexler Gauge SN: n/a Std. Density Count: n/a TERRA-MAR, INC. Std. Moisture Count: n/a / Mille Fuller ~ Project Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. o?nI~C Page I of I