Four Seasons 2R-LR050208FIELD DENSITY TESTING
Report Number: 94041388.0061
Service Date: January 24, 2005
'lrerracan
8901 Carpenter Fn,w. Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Hill & Wilkinson LTD
Attn: Charles Hoagland
800 Klein Rd Ste 100
Piano TX 75074
Report Date: February 08, 2005
Project: BCE Specialties
989 West Sandy Lake Road
Coppell, TX
Project Number: 94041388
Material Information Lab Test Data Project Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pc0 (%) (% compaction)
1. 413880001 ASTM D 698 Brown silty clay w/gravel
17.2 105.7 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) /~'"~ (%) (pot} (% compaction)
Fire Lane
150 40' N & 60' E from NW corner of bldg. Subgrade 1 6 16.3 103.9
pad
151 50' N & 120' E from NW corner of bldg. Subgrade 1 6 17.1 103.3 / 98
pad
152 55' N & 260' E from NW corner of bid9 Subgrade 1 6 16.7 103.7 98
pad
153 48' N & 385' E from NW corner of bldg. Subgrade 1 6 16.5 103.1 98
pad
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of ~iom~c~n and material moisture
condition. ~/ f~'~
Field Test Method:ASTM D2922, ASTM D3017 '~. "
Technician: Nicholas K. Ciofani r~
Field Results Reported To: Hill & Wilkinson Rep
Report Distribution:
(1) Hill & Wilkinson LTD (1) TMBP Consulting Engined
(1) City of Coppell TX (1) BCE Special[ids Reviewed by:
(1) City of Coppell TX Robert D. Ray, S.E.T.E.T~
(1) Hardy McCuI[ah/MLM Architects If~c Senior Project Mal;~er
The tests were performed in general accordance with applicable ASTM. AASHTO. or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials