Loading...
Park West CC(02-2)-CS050223DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ~TEM: Park West Commerce Center~ Lot 2R-3~Block 2~ Site Plan, to allow the development of two office warehouse buildings (137,000-square-feet and 153,000-square-feet, respectively,) on 16.8 acres of property located at the northwest comer of B¢ltline and Airline Roads, at the request of Kyle McCullah, Hardy McCullah/MLM Architects, Inc. STAFF REP.: Gary Sieb PROJECT ID# SPA-05-0009 DRC DA TE: FEBRUARY 23, 2005 and MARCH 3, 2005 CONTACT: Kenneth M. Gri[~n, P.E., Dir. o[ En~ineerin~/Public [Forks 972/304-3686 Sheet Cl.0: 1. Show the location of FDC's on the drawings. 4. Provide verification from the adjacent property owner to the west that allows this development to connect to the adjacent property's fire line. 5. The screening wall cannot be located in the drainage easement. 4. The City anticipates beginning construction of a new 16" water line adjacent to this site in mid 2005. There will need to be coordination between this development and the City pertaining to taps, location and timing. Sheet Cl.1: 1. Provide manholes where private storm drains meet public storm drains. 2. Provide profiles o f storm draln including any crossing utilities. 3. The location of the inlet at the northeast comer of the property will need to be relocated due to the requested mutual access easement. Sheet A-1.0: 1. The proposed 50' driveway exceeds the maximum 40' driveway allowed by the Subdivision Ordinance. You should consider moving the median noses to align the median opening with the driveway. · Additional requirements may be identified during fuji engineeringplan review. DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ~TEM: Park West Commerce Center~ Lot 2R-3~ Block 2~ Replat, being a replat of Park West Commerce Center, Lot 2R-2, Block 2, to allow the development of two office warehouse buildings (137,00-square-feet and 153,000-square- feet, respectively,) on 16.8 acres of property located at the northwest comer of Bcltline and Airline Roads, at the request of Ryan Safford of Pacheco Koch Consulting Engineers. STAFF REP.: Gary Sieb PROJECT ID# RP-05-0010 DRCDATE: FEBRUARY 23, 2005 and MARCH 3, 2005 CONT.,I CT: Kenneth M. Gri~n, P.E., Dir. o[ En~ineerin~/Public Works 972/304-3686 COMMENT STATUS: ,,"PRELIMINARY glNA:g P~.qSED 1. Provide a mutual access easement for the property to the north at the northern driveway. 2. Add the floodplain signature block to the plat. 3. Only 10 foot of the 20 foot Utility and Drainage Easement dedicated by Volume 90218, page 3264 can be abandoned. There still must be a minimum 20 foot Utility and Drainage Easement centered over the existing 72" RCP. This will affect the placement of your screening wall shown on Sheet A-1.0.