CONCRETE COMPRESSIVE STRENGTH TEST
Client: Duke Realty Services, LP
Mr. Brian Sl~aley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
·
Project: Freeport~XI & XII I
'-c-oppell, I exms
Services:
Report No.: 226373
Project No.: 049245
Date of Service: 01/19/2005
Report Date: 02/21/2005
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: SouthelTl Star
PLANT: 27
SPECIFICATION REQUIREMENTS
STHENGTH: 3000 psi ~ 28 Days
SLtmr (in): 5" maximum
Am('/.): 3% - 6%
TEST METHOD: ASTM C- 172
ASTM C-31 ~:
ASTM C-143
ASTM C-231
ASTM C- 1064
ASTM C-1231
ASTM C-39
MIX DESIGN I.D.: 7750 MEASURED
SLUMP
PLACEMENT DATE: 01/19/2005 (inches)
WEATHER CONDITIONS: Clear 5.0
TIME SAMPLED: 3:30am BATCH TIME: 3: I 0am
TEMPERATURE (F} - Am 40 F CONCRETE: 51 g
TRUCKNO: 8 TICKET NO: 763692
AIRCONTENT(%): 4.4 UNIT WEIGHT (pc0: NA
OVERALL PLACEMENT LOCATION:
Paving, east parking lot and fire lanes, Building 12, east half of north parking lot and fire
lanes, Building 12
SAMPLE LOCATION:
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
CYLINDER MAXIMUM COMPRESSIVE
MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE
1 1 01/26/2005 7 5.99 28.17 97140 3450 Unbonded Cap
~28/ 6.00 28.26 126820 4480 ~ UnbondedCap
1
2
02/16/2005
1 3 02/16/2005~r 6.00 28.26 130390 ~ Unbonded Cap
Average
1 4 Hold
Water added at site:
5 gallons~
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our lei~ers and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in f~ll without the written approval of Rone Engineers, Ltd.
HSS Page I of 10
Client:
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.: 226373
Project No.: 049245
Date of Service: 01/19/2005
Report Date: 02/21/2005
Services:
Obtain samples of fzesh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: Southerll Star
PLANT: 27
SPECIFICATION REQUIREMENTS
3000 psi ~ 28 Days
5" maximum
3% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C- 1231
ASTM C-39
MIX DESIGN I.D.: 7750 MEASURED
SLUMP
PLACEMENT DATE: 01/19/2005 (inches)
WEATHER CONDITIONS: Clear 4.5
TIME SAMPLED: 4:25am BATCHTIME: 4:00am
TEMPERATURE (F) - AIR 41 F CONCRETE: 52 F
TRUCK NO: NA TICKETNO: 763699
AIR CONTENT (%): 4.5 UNIT WEIGHT (pc0: NA
OVERALL PLACEMENT LOCATION:
Paving, east parking lot and fire lanes, Building 12. east half of north parking lot and fire
lanes, Building 12
SAMPLE LOCATION:
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
90' south of northeast comer, 30'
east of east wall
CYLINDER MAXIMUM COMPRESSIVE
MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE
2 1 01/26/2005 7 5.99 28.17 97580 3460 Unbonded Cap
2 2 02/16/2005 28 6.00 28.26 128160 4530 Unbonded Cap
2 3 02/16/2005 28 6.00 28.26 138960 4910 Unbonded Cap
Average 4720
2 4 Hold
Water added at site:
5 gallons
LiMITATiONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject manet provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in f~ll without the written approval of Rone Engineers, Ltd.
Page 2 of 10
Client:
ineers
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.: 226373
Project No.: 049245
Date of Service: 01/19/2005
Report Date: 02/21/2005
Services:
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
CONTRnCTOR: Duke Construction
CONCRETE SUPPLIER: Southerll Star
PLANT: 27
SPECIFICATION REQUIREMENTS
3000 psi ~ 28 Days
5" maximum
3% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
MEASURED
MIX DESIGN I.D.: 7750 SLUMP
PLACEMENT DATE: 01/19/2005 (inches)
WEATHER CONDITIONS: Clear 5.0
TIME SAMPLED: 5:30am BATCHTIME: 5:09am
TEMPERATURE (F} - AIR 42 F CONCmSTE: 51 V
TRVCK NO: 1815 TIC~T NO: 763709
AIR CONTENT (%): 4.5 UNIT WEIGHT (pc0: NA
OVERALL PLACEMENT LOCATION:
Paving, east parking lot and fire lanes, Building 12, east half of north parking lot and fire
lanes, Building 12
SAMPLE LOCATION:
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
80' north of southeaat comer, 25'
east of east wall
CYLINDER MAXIMUM COMPRESSIVE
MARleD DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE
3 1 01/26/2005 7 5.99 28.17 95340 3380 Unbonded Cap
3 2 02/16/2005 28 6.00 28.26 126910 4490 Unbonded Cap
3 3 02/16/2005 28 6.00 28.26 123500 4370 Unbonded Cap
Average 4430
3 4 Hold
Water added at site:
5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in qualily
· (composition, appezrance, performance, etc.) or any other feature of similar subject mailer provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
}ISS Page 3 of 10
Client:
ineers
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.: 226373
Project No.: 049245
Date of Service: 01/19/2005
Report Date: 02/21/2005
Obtain samples of fi'esh concrete at the placement locations, perform required field testing, cast compressive s~ength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
STRENGTH:
SLUMF (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: Southcrn Stay
pl.~rr: 27
SPECllqCATION REQUIREMENTS
3000 psi ~ 28 Days
5" maximum
3% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
MEASURED
MIX DESIGN I.D.: 7750 SLUMP
PI~.CEMENT DATE: 01/19/2005 (inches)
WEATHER CONDITIONS: Clear 5.0
TIME SAMPLED: 6:00am BATCH TIME: 5:30am
TEMPERATURE (F) - AIR 60 F CONCRETE: 43 F
TRUCKNO: 923 TICKETNO: 763722
AIR CONTENT (%): 4.5 UNIT WEIGHT (per): NA
OVERALL PLACEMENT LOCATION:
Paving, east parking lot and fire lanes, Building 12, east half of north parking lot and fire
lanes, Building 12
SAMPLE LOCATION: See below
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
CYLINDER MAXIMUM COMPRESSIVE
MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE
4 1 01/26/2005 7 5.99 28.17 97470 3460 Unbonded Cap
4 2 02/16/2005 28 6.00 28.26 130950 4630 Unbonded Cap
4 3 02/16/2005 28 6.00 28.26 136710 4830 Unbonded Cap
Average 4730
4 4 Hold
Sample location: 10' south of north curb, east half of north parking lot, and
10' east of expansion joint at center of parking lot running north and south
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are ad~-essed and shall not be reproduced except in f~ll without the wfiiten approval of Rone Engineers, Ltd.
01SS Page 4 of I0
~eport No.: 226373 RoneEngineers
?roject No.: 049245 Client: Duke Realty Services, LP
Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our Icaers and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01SS Page 5 of 10
Client:
Duke Realty Services, LP
Mr. Brian Sttaley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214l 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.: 226373
Project No.: 049245
Date of Service: 01/19/2005
Report Date: 02/21/2005
Services:
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive s~'ength samples and bring
samples back to the laborato~ for curing and testing in accordance with applicable standards.
PROJECT DATA
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: Southem Star
PLANT: 27
SPECIFICATION REQUIREMENTS
3000 psi ~ 28 Days
5" maximum
3% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
MIX DESIGN LD.: 7750 MEASURED
SLUME
PLACEMENT DATE: 01/19/2005 (inches)
WEATHER CONDITIONS: Clear 5.0
TIME SAMPLED: 9:00am BATCH TIME: NA
TEMPERATURE (F) - AIR 49 V CONCRETE: 53 F
TRUCKNO: 923 TICKETNO: 763730
AIR CONTENT (%): 4.6 t~rr WEIGHT (pc0: NA
OVERALL PLACEMENT LOCATION:
Paving, east parking lot and fire lanes, Building 12, east half of north parking lot and fire
lanes, Building 12
SAMPLE LOCATION:
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
See below
CYLINDER MAXIMUM COMPRESSIVE
M3.RKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE
5 1 01/26/2005 7 5.99 28.17 93840 3330 Unbonded Cap
5 2 02/16/2005 28 6.00 28.26 120170 4250 Unbonded Cap
5 3 02/16/2005 28 6.00 28.26 125450 4440 Unbonded Cap
Average 4350
5 4 Hold
Sample location: North parking lot,
35' south of north curb, 20' east of
expansion joint at center of north parking lot running north and south.
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject mimer provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in fi~lI without the written approval of Rone Engineers, Ltd.
01SS Page 6 of 10
Report No.: 226373
Project No.: 049245 Client: Duke Realty Services, LP
Water added at site: 7 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation m quality
(composition, appearance, performance, ete.) or any other feature of similar subject mat*er provided by persons or conditions over which we have no con~'ol. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
alSS Pa-e 7 of 10
Client:
ineers
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.: 226373
Project No.: 049245
Date of Service: 01/19/2005
Report Date: 02/21/2005
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: Southern Star
PLANT: 27
SPECIFICATION REQUIREMENTS
3000 psi ~ 28 Days
5" maximum
3% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
MEASURED
MIX DESIGN I.D.: 7750 SLVM~
PLACEMENT DATE: 01/19/2005 (inches)
WEATHER CONDITIONS: Clear 4.5
TIME SAMPLED: 10:05am BATCHTIME: 9:48am
TEMPERATURE (F)- AIR 55 F CONCRETE: 53 F
TRUCKNO: 1827 TICKETNO: 763741
AIR COWrENT (%): 4.6 UN1TWEIGHT(pc0: NA
OVERALL PLACEMENT LOCATION:
Paving, cant parking lot and fire lanes, Building 12, east half of north parking lot and fire
lanes, Building 12
SAMPLE LOCATION: See below
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
CYLINDER MAXIMUM COMPRESSIVE
MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (Ib~. force) (psi) TYPE
6 1 01/26/2005 7 5.99 28.17 79920 2840 Unbonded Cap
6 2 02/16/2005 28 6.00 28.26 104920 3710 Unbonded Cap
6 3 02/16/2005 28 6.00 28.26 108770 3850 Unbonded Cap
Average 3780
6 4 Hold
Sample location: North parking lot, east half, 60' north of south curb, 10' east
of expansion joint at center of north parking lot running north and south.
LIMITATIONS: The test results presented herein were prepared bared upon the specific samples provided for testing. We arsume no responsibility for variation in quality
(composigon, appearance, performance, etc.) or any other feature of similar subject maRer provided by persons or conditions over which we have no control. Our letters and
repons are for the exclusive use of the clients to whom they are addressed and shall no! be reproduced except in full without the written approval of Rone Engineers, Ltd.
01SS Page 8 of 10
Report No.: 226373
Project No.: 049245 Client: Duke Realty Services, LP
Water added at site: 20 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We ~ssume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject mailer provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Ron¢ Engineers. Ltd.
OISS Page 9 of 10
Client:
ineers
Duke Realty Services, LP
Mr. Brian S~aley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.: 226373
Project No.: 049245
Date of Service: 01/19/2005
Report Date: 02/21/2005
Obtain samples of fi-esh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
STRENGTH:
SLUMI' (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: Southern Star
PLANT: 27
SPECIFICATION REQUIREMENTS
3000 psi ~ 28 Days
5" maximum
3% - 6%
ASTM C- 172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
MIX DESIGN LO.: 7750 MEASURED
SLUMP
PLACEMENT DATE: 01/19/2005 (inches)
W~ATtmR CO~ITIONS: Clear 5.0
TIMESAMELED: 12:10pm BATCHTIME: ll:41am
TEMPERATURE (F) - AIR 59 F CONCRETE: 54 F
TRVCIC NO: 8003 TICKET NO: 384441
Am CONTENT (%): 4.6 trmr WEIGHT (pc0: NA
OVERALL PLACEMENT LOCATION:
Paving, ezst parking lot and fire lanes, Building 12, east half ofnarth parking lot and fire
lanes. Building 12
SAMPLE LOCATION:
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
See below
CYLINDER MAXIMUM COMPRESSIVE
MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE
7 1 01/26/2005 7 5.99 28.17 83640 2970 Unbonded Cap
7 2 02/16/2005 28 6.00 28.26 109220 3860 Unbonded Cap
7 3 02/16/2005 28 6.00 28.26 104240 3690 Unbonded Cap
Average 3780
7 4 Hold
Sample location: North parking lot, 75' north of south curb, 20'
expansion joint at center of parking lot running north and south
east of
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject mat~er provided by persons or conditions over which we have no control. Our leaers and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in f~ll without the wriaen approval of Rone Engineers, Ltd.
IISS Page 10 of 10
Technician: Pat Parks
Report Distribution:
(1) Duke Realty Services, LP
( 1 ) Extranet
(1) City of Coppell
(1) City of Copp¢ll
Started: 2:30am
Finished: l:30pm
CMT Operations Manager