Loading...
Vista Point II L5-CS050223DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Vista Point II~ Lot 5~ Block A Replat (Bank of Texas), to revise the location of the fire lanes to allow thc development of an approximate 5,585- square-foot bank facility with drive-through lanes on 1.25 acres of property located along the west side of MacArthur Blvd., south of S.H. 121, at the request ofPles Schnitz, Schnitz and Sewell. STAFF REP.: Marcie Diamond PROJECT ID# RP-05-0002 DRCDATE: FEBRUARY 23, 2005 and MARCH 3, 2005 CONTACT: Kenneth M. Griffin, P.E., Dir. of En~ineerin~Public Works 972/304-3686 COMMENT STATU$:]'"'PRELIMINARYI r gglztr, E-D Plat: 1. If the 12" water line along MacArthur is as shown on thc site plan, a 20' utility casement centered on the water line in needed. 2. Show the Coppell/Lewisvillc City Limits on this sheet. Site Plan: 1. Thc monument sign must be moved out of the proposed 20' utility easement required for the 12" water line. 2. New sidewalk shall bc 5'-0" wide instead of 4'-0". 3. Show thc curb linc for Lake Vista Drive on this drawing. Does the proposed south driveway align with Lake Vista? 4. Is a left turn lane proposed for the south driveway? 5. Whether a car or truck can safely make a left turn fi.om the south proposed driveway, is unclear due to the northern median nose encroaching into the radius of the driveway. 6. It's my understanding that the City of Lewisville may require deceleration lanes adjacent to this site. Has the site plan been revised to reflect all of Lewisville's concerns, issues and/or requirements? Utility Plan: 1. The water line stub out shown to end under the dumpster must be extended outside the limits of concrete. 2. Show existing storm sewer piping on the drawing. 3. Design the private fire line so there is no dead end. 4. The proposed location of the fire vault is too close to tree ET-8. 5. Tap the 12" water line only once and run both irrigation and domestic water off that tap. 6. Provide proof of permission from adjacent property owners to work offsite and to install water line stub outs and fire hydrants. 7. Is the 8" Sanitary Sewer Line "SS-I" public? 8. Explain the reasoning for the configuration of the water line at the northwest comer of the property. Grading Plan: 1. Provide more elevation information along the eastern portion of the property so that flow may be determined. All water must be picked up on site. Erosion Control Plan: 1. Provide inlet protection at all inlets on the site. 2. Note that all erosion control notes and details shall conform to TCEQ regulations. Erosion Control Details: 1. Stabilized Construction Entrance Detail shall match corresponding Notes. (Is the minimum thickness 6" or 8"?) · The offsite utility and paving work to support this project needs to be submitted prior to receiving any permits for the development. DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: PD-199R2-HC, Vista Point II, Lot 5~ Block A (Bank of Texas), zoning change request from PD-199-HC (Planned Development-199-Highway Commercial) to PD-199R2-HC (Planned Development-199 Revision 2- Highway Commercial) to allow the development of an approximate 5,585- square-foot bank facility, with drive-through lanes, on 1.25 acres of property located along the west side of MacArthur Blvd., south of S.H. 121, at the request ofPles Schnitz, Schnitz and Scwell. STAFF REP.: Marcie Diamond PROJECT ID# PD-05-0001 DRCD,4TE: FEBRUARY 23, 2005 and MARCH 3, 2005 CONTACT: Kenneth M. Gri~n, P.E., Dir. o~ Enfineerin~/Public Works 972/304-3686 COMMENT STATUS: ~PRELIMINARY I F4NA~ vr~c See comments under Replat / Project ID# RP-05-0002.