REPORT OF IN-PLACE DENSITY AND MOISTURE OF SOIL
Density Rsp. o. rt.,I~lo. 14 (204-0164) Method: ASTM D2922 D3017 D698 Pose of 2
Required Dcnsdy
PavmR & Irenches - Min. 95%;
Lots - 9~.105°A,
Required Moisture
Paving & trenches - 0 to *4%:
Lots - 0 to
2 G~ lateral - I' belo'* grade
91 Between 4.40 & 444, Hidden Valley Dr.
4 Gas latcraI- 1' below grade
92 East end of 444-
4 Electrical lateral - I' below grade
q3 West of NW corner of Block B. Lot I I 13.2 16,4" 94.3 *
1 Electrical lateral - I' below grade
94 South of SE comer of Block B, Lot 3 104.8 16,5 97 0
95 Between Block C. Lot 8. Lot 3 I ! 1.5 17.0 103, l
~ Electrical lateral - 1' below grade
96 At SW comer of 448 Hidden Valley Dr. 108.6 [ 8.7 ! 00.4
4 Gas lateral - I' below grade
97 Between B}ock A, Lot2 & Block B, Lot I 120,4 11.8 100.4
* Test result~ do not meet project specifications
TEXAS CMT, INC.
DALLAS, TEXAS
(214) 352-6957
REPORT OF IN-PLACE DENSITY AND MOISTURE OF SOIL
Density Repor~ No. 14 (204-0164~ Method: ASTM D2922 D3017 D695 Parc 2 of 3
Client: Street Real gstate Mat~n~t Descnptton M~ximum Optimum
Project: Hidden Valley Estates ([.b~CuF~) Percent
Report Date: Janus ~ 26, 2005 ~ Light Brown Clayey Sand 119.9 I 1.7
Required Ocnsi~ (%):
Paving & trenches - Min. 95%;
Lo~s - 9~ 105%
Required Moisture
Paving & trenches - 0 to +4%;
Lots - 0 ~o 5%, ~%
4 Electrical lateral - V below grade
98
4 Elzctrica] lateral - I' below grade
gq At west end of
5 Retest ~ 93
{00 l l0,1 15.7 96.0
Test results do not meet project specifications
TOTRL P.04