Loading...
Freeport NIP(8.0)-LR050301ineers 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST -- 0~' . 227103 Client: Duke Realty Services, LP ~TJ~ /~ ~ Report No.: Mr. Brian Sitaley ~ '" ~,s,.[] ,jr Project No.: 049245 5495 Belt Line Rd., Ste 360 ,,~ ,' ~'~ ~' Jf ~of Service: 01/29/2005 Dallas TX 75254 _ ~ f~' ..,,,,'"~e~rt Date: 03/01/2005 Project: Freep°rt XI & XIID / //J / Coppell, Texas -- '~ / / Services: Obtain samples of fresh concrete at the placement Iocations~red fiel~esting, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applica~e stand~cls. PROJECT DATA~ co c o , CONCRETE SUPPLIER: Southern Star (inches) STRENGTH: SLUMP (in): AIR (%): TEST METHOD: PLANt: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 3" - 5" 3% - 6% ASTM C- 172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C- 1064 ASTM C-1231 ASTM C-39 WEATHER CONDITIONS: Cloudy TIME SAMPLED: 8:15aril BATCH TIME: 7:554m TEMPERATURE (F)- AIR 49 F CONCRETE: 63 F TRUCKNO: 923 XIC~,~TNO: 782295 AIR CONTENT (%): 4.8 UNIT WEIGHT (pcl): NA OVERALL PLACEMENT LOCATION: Paving, en'ayway 10' north. 45' east from northeast comer of Building I 1 5.25 SAMPLE LOCATION: REPORT OF TESTS 25' east, 25' south fi.om northeast comer of Building 11 Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 1 1 02/05/2005 7 6.00 28.26 134300 4750 Unbonded Cap 1 2 02/26/2005 ~"~/ 6.00 28.26 178400 ~ Unbonded Cap 1 3 02/26/2005 ~ 6.00 28.26 170950 ~ Unbonded Cap Average 6180 1 4 Hold LIMITATIONS: The test results presented herein were prep0red based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. :)ISS Page 1 of 3 Client: ineers Duke Realty Services, LP Mr. Brian Slxaley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 227103 Project No.: 049245 Date of Service: 01/29/2005 Report Date: 03/01/2005 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Duke Construction CONCRETE SUPPLIER: Southerll Star PtANT: 27 SPECIFICATION REQUIREMENTS STRENGTH: SLUM? (in): AIR (%): TEST METHOD: 4000 psi ~ 28 Days Y' - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C- 1231 ASTM C-39 MIX DESIGN I.D.: 7752 MEASURED SLUMP PLACEMENT DATE: 01/29/2005 (inches) W~ATHER COm>ITIONS: Cloudy 5.0 TIME SAMPLED: 9:30am BATCHTIME: 9:05am TEMEERATURE (F) - AIR 52 F CONCRETE: 65 F TRUCK NO: 1827 TICKET NO: 782307 AIR CONTENT (%): 5.3 UNIT WEIGHT (pcO: NA OVERALL PI~ACEMENT LOCATION: Paving, enlxyway 10' north, 45' east from no~ea~ co~lker of Building~i~~,' SAMPLE LOCATION: 15' north, 20' eaat, qrom northeast REPORT OF TESTS comer of Building 11 Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) T~PE 2 1 02/05/2005 7 6.00 28.26 146470 5180 Unbonded Cap 2 2 02/26/2005 28 6.00 28.26 ~030 6930 Unbonded Cap 2 3 02/26/2005 28 6.00 28.26 ~k95}90 6920 Unbonded Cap ge 6930 2 4 Hold LIIvffrATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, ete.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letturs and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except th f~ll withom the written approval of Rone Engineers, Ltd. ~ISS Page 2 of 3 ineers 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Duke Realty Services, LP Mi'. Brian Slraley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas Report No.: 227103 Project No.: 049245 Date of Service: 01/29/2005 Report Date: 03/01/2005 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: com~,nCrOR: Duke Construction CONCRETE SUPPLIER: Southcrll Star PLANT: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 3" - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-I064 ASTM C- 1231 ASTM C-39 MIXDESIGN I.D.: 7752 PLACEMENT DATE: 01/29/2005 WEATHER CONDITIONS: Cloudy TIME SAMPLED: 10:20a111 BATCHTIME: 9:55am TEMPERATURE (F) - AIR 52 F CONCRETE: 66 v TRUCKNO: 1827 TICKET No: 782315 AIR CONTENT (%): 5.1 UNITWEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: Paving, entryway 10' north, 45' east fi-om northeast comer of Building 11 SAMPLE LOCATION: 35' east, 95' north from northeast REPORT OF TESTS corner of Building 11 MEASURED SLUMP (inches) 5.5 Concrete Compressive Cylinder 6" x 12" CYLINDER MARKED DATE SET NO. TESTED 3 1 02/05/2005 3 2 02/26/2005 3 3 02/26/2005 3 4 Hold Technician: Jeremy Watts Report Distribution: (1) Duke Realty Services, LP (1) Extranet (1) City of Coppelt (I) City of Coppell MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH FRACTURE (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 7 6.00 28.26 113450 4010 Unbonded Cap 28 6.00 28.26 151500 5360 Unbonded Cap 28 6.00 28.26 152070 5380 Unbonded Cap Average 5370 Started: 8:00am Finished: l l:30am · K -Soott CMT Operations Manager LIMITATIONS: The ~:st results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. ~ISS Page 3 of 3