Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
SS9901-SP050222 (7)
210 Sonneborni waterproofing Systems SONOSHIELD® HYDROCIDE® 600, 700, 700B Waterborne emulsified-asphalt dampProofing compounds Features Benefits · Speeds dampproofing of new Foundation walls · Minimizes fire hazards during application · User friendly · Withstands normal expansion and contraction · Suitable for most climates Where to Use Hydrocide® 600, 700 and 700B · Exterior surfaces below grade · Faces of cavib/walls How to Apply Hydrocide:e 600, 700, and 700B hnlshed grade [] Backfilling: Place backfill at least 24 to 48 hours after applica- tion but within 7 days Do not rupture or damage the film or displace the coating or membranes Some situations may require protecbon board Exterior surfaces below grade-- porous surfaces Three alternate techniques are equally effective [] Membrane system: Apply 1 coat of Hvdrocide® 700 or 2 coats of Hydrocide® 70OB as described abcve under Dense Sun-aces Within 4 hours apply Sonoshield® Reinforcing Fabric or glass fabric membrane cloth over all surfaces of coating overlapping alt edges at least 3" (76 mm) Press firmly into place without wrinkles Within 24 hours, apply an addrt~onar coat of Hydrocide~"~ 700 or Hvdrocide® 700B Allow to set and backfill as descnbed above under Backfilling For Best Performance · Do not apply at temperatures below 40°F (4°0 or when rem. peratures are expected to fall to 40~F (4°C) in the next 24 hours · DO not use Hydrocide® 700 and 700B as plaster bonds on ceilings or under Portland cement mixes on ceilings · Hydrocide® products should not be exposed to long term UV [] ~vo-coat system: Apply a prime coat of HydrocJde® 600 asphalt emulsion, cut 20% by volume with clean water Allow prime coat to dry tacky to touch and apply I coat of Hydrocide® 700 as described above under Dense Surfaces Allow to set and backfill as described above under Backfilling [] Parge coat system: Apply a parge coat of cement mortar to the block wall carrying the earge coat from the bottom of the footings to grade level and forming a cove at the junction of the wall and footing Allow to cure (typically 7 days) Apply either 1 trowel coat of Hydrocide® 700 or 2 brush rolleE or spray coats of Hydrocide® 700B as described above under Dense Surfaces Allow to set and backfill as described abc¢ve under B~illinO Interior surfaces above grade-- vapor retarder I[]1 Hydrocide® 600 700 and 700B may be used individually or ~n combination for dampproofing the exterior face of interior walls in cavity wall construction · Make certain the most current version of this data guide is being used: call Customer Service (1-800-433 9517) to verify the most current version · Not intended as a waterproofing membrane Refer to HLM® 5000 (Form NO 1017900) [] HvdrOClde~ 700 and 4ydFOClde® 7008 are excellent vapor retard®ps Apply in 1 coat, carrying the coat ng in and around all joints grooves, and slots, following all reveals ano sofhts of windows and continuing '12' 305 mm) out on adjoining parLiPons and soffits Hvdroclde® 600 may also be useo Use 1, 2 or more coats as needed depenaing on amount of vapor retarding called for [] Allow to set If walls are receive hard wall plaster use furring strips or metal lath [] Hvdrocide~ 700 and 700~ have been used successfully for bonding polysWrene ~nsulatio[ board to a wide varieb/of substrates On-site testing with actual substrate is recommenaed Clean Up · Proper applicaoon is the respon sibJlity Of the user Field visits by ChemRex® personnel ar e For tn® purpose of making technica, recommendations only and are not For supervising or providing qualib/control on the jobsite 7 ................... degusso. Technical Data Compliances ASTM D i187, Type l, and ASTM D 1227-95, Type 5r Class I · ~ya~oclde~ 700 compiles with ASTM D 1227-95, Type 2, Class I and ASTM D 1187, Type I · Hvdrocide~ 700B complies with ASTM D 1227-95, Type 2, Class I, and ASTM D 1187, Type 1 Typical Proper des % Solids byvolume % Solids by weight Hydrocide~600 50 52 Hydrocide~700 52 54 Hydrocide~700B 51 55 Vlscoslt¢ ' Res~llt ~: Method Hydrocide· 600, KU 95 - 605 Stormer Hydrocide· 700 ' 525 - 555 Penetrometer, t6 oz. CUp, ISO g, weight Hydrocide· 70OB, KU 110 - 120 Stormer Order Information 55 Gallon Drums 5 Gallon Cans (208 L) (18.93 L} Hydrocide· 600, lbs, (kg) 47 (21) Hydrocide· 700, lbs, (kg) 520 (236) 47 Hydrocide· 7008, lbs, (kg) '" 47 [21} · Hydrocide~ 600: A nonfibratad asphalt emulsion dampproofing for application by brush or spray · Hyd rocide~ 700: Fibrated asphalt- emulsion damporoofing for application by trowel · Hydrodde~ 70OB: Asphalt emul- sion similar to Hydrodde~ 700, but reinforced with shorter fibers for brush or spray application Caution Hydrocide· 600, 700 and 7008 contain asphalt, petroleum, silica, aluminum silicate Risks May cause skin, eye and respiratory irritation Ingestion may cause irritation Precautions KEEP OUT OF THE REACH OF CHILDREN. Avoid contact with skin, eyes and clothing Avoid breathing vapors Wash thoroughly after Do not allow these materials to freeze in container; do. not store below 35OF (2°0 Shelf life is t~pically 1 year when stored in unopened containers under normal conditions handling, Use only with adequate ventilation. Keep container closed when not in use DO NOT take internally Use impervious gloves, eye protection and if the TLV is exceeded or if used in a poody ventilated area, use NIOSH/MSHA approved respiratory protect[on in accordance with applica- ble federal, state and local regulations All lapel warnings must be observed until the container is commerdally cleaned or reconditioned First Aid In ease of eye contact, flush thoroughly with water for at least 15 Hydrocide· 600 70 - I00 sq, ft, per gallon per coat (1,72 - 245 m2/D Hydrocide· 700 1/16" wet film: 25 sq ft per gallon (1.6 mm wet film: 0,61 m2/L) 1/8' wet film: 12,5 sq, ft. per gallon (3 mm wet film: 0.31 Hydrodde~ 700B 50 - 35 sq. ft, per gallon per coat (0.74 - 0.87 m~/L per coat) minutes. SEEK IMMEDIATE MEDICAL AIFENTION. In case of skin contact, remove completely with dry cloth, then wash affected areas with soap and water If irritation persists, SEEK MEDICAL ATTENTION If inhalation causes physical discomfort, remove to fresh air, If discomfort persists or any breathing difficulty occurs or If swallowed, SEEK IMMEDIATE MEDICAL ATTENTION Refer to material safety data sheet (MSDSI for further information, Proposition 65 This product contains materials listed by the state of CalIfornia as known to cause cancer and birth defects or other reproductive harm VOC Content Hydrocide® 600, 700, and 700B contain 30 g/L or 025 lbs of VOC per gallon of coating less water and exempt solvents. For medical emergencies only, call chemTrec 1/800/~24-9300. Limited Warranty Notice Every reasonable effor~ ia made to apply ChemRex® exacting standards both in the manufacture of our products and in the information which we issue concerning these products and their use We warrant our products to be of good quality and will replace or, at our election, refund the purchase price of any products proved defective, Satisfactory resuEs depend not only upon qualiW products, but also upon many factors beyond our control Therefore, except for such replacement or refund, CHEMREX® MAKES NO WARRANTY OR GUARANTEE, EXPRGSS OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, RESPECTING ITS PRODUCTS, and CHEMREX® shall have no other liability with respect thereto. Any claim regarding product defect must be received in writing within one (11 year from the date of shipment No claim will be considered without such written notice or after the specified time interval User shall determine the suitability of the products for the intended use and assume all risks and liabLlity in connection therewith Any authorized change in the printed recommen- dations concerning the use of our products must bear the signature of the ChemRex® Technical Manager ISonnebordl corporate Office: 989 Valley Park Drive; Shakopee, MN 55379 Cuetomer Service: 1/8OO/433-9517 TeChnical Services: 1/800/ChemRex (1/8OO/243-6739) web Site: www chemrex cpm Form No. 1017895 © 2002 ChemRex® For professional use only. Not for sale to or use by the general public. ~ Printed on recycled paper including 10% post-consumer fiber 11M 1/02 Replaces 1/01