Loading...
Vista Point II L5-CS050303 (2)DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Vista Point lit Lot 5~ Block A Replat (Bank of Texas), to revise the location of the fire lanes to allow the development of an approximate 5,585- square-foot bank facility with drive-through lanes on 1.25 acres of property located along the west side of MacArthur Blvd., south of S.H. 121, at the request of Pies Schnitz, Schnitz and Sewell. STAFF REP.: Marcie Diamond PROJECT 1D0 RP-05-0002 DRC DA TE: FEBRUARY 23, 2005 and MARCH 3, 2005 CONTACT: Kenneth M. Griffin, P.E., Dir. of En~ineerin~/Public Works 972/304-3686 COMMENT STATUS: " t~&~Y ,/FINAL ~ Plat: 1. There is not an offset in the City Limits between Coppeli and Lewisvilie as you show along the northeast corner. Site Plan: 1. The proposed access on the south side of the property is not aligned with Lake Vista Drive. Because of safety considerations please align this access with Lake Vista Drive. 2. It's my understanding that the City of Lewisville may require deceleration lanes adjacent to this site. Has the site plan been revised to reflect ali of Lewisville's concerns, issues and/or requirements? Utility Plan: 1. Be sure utilities shown on these plans coordinate with proposed utilities by Pacheco Koch. 2. Provide proof of permission from adjacent property owners to work offsite and to install water line stub outs and fire hydrants. 3. Need to provide proof of a property owners association to maintain the water, sewer and drainage systems. They cross several property lines. If there is not proof of property owners association, then most of these utilities will need to be in a 20' utility easement. 4. Explain the reasoning for the configuration of the water line at the northwest corner of the property. · The offsite utility and paving work to support this project needs to be submitted prior to receiving any permits for the development. DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: PD-199R2-HC~ Vista Point II~ Lot 5~ Block A (Bank of Texas), zoning change request from PD-199-HC (Planned Development-199-Highway Commercial) to PD-199R2-HC (Planned Development-199 Revision 2- Highway Commercial) to allow the development of an approximate 5,585- square-foot bank facility, with drive-through lanes, on 1.25 acres of property located along the west side of MacArthur Blvd., south of S.H. 121, at the request of Pies Schnitz, Schnitz and Sewell. STAFF REP.: Marcie Diamond PROJECT ID# PD-05- DRC DATE: CONTACT: COMMENT STATUS: 0001 FEBRUARY 23, 2005 and MARCH 3, 2005 . P.E., Dir.4 ,~ FINAL 972/304-3686 See comments under Replat / Project ID//RP-05-0002.