Loading...
Four Seasons 2R-LR050322CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94041388.0076 Service Date: February 21,2005 Client: Hill & Wilkinson LTD Attn: Charles Hoagland 800 Klein Rd Ste 100 Plane TX 75074 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: March 22, 2005 Project: BCE Specialties 989 West Sandy Lake Road Coppell, TX Project Number: 94041388 Material Information Specified Strength: 5000 psi @ 28 Days Batch Time: 10:21 am Supplier: Southern Star Truck No: 1016 Mix I.D. No.: 7503 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, O F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Plant: 66 Ticket No: 769344 0 Gallons 0 Gallons Result 8.50 4.3 73 74 Sample Information Sample Time: 11:00 am Date Cast: February 21,2005 Technician: Bradley W. Hatch Weather Conditions: Clear, windy Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Bottom half of Panel No. 4 Placement Location: Panel No. 4 Specification Test Method 7-9 ASTM C143 4-6 ASTM C231 ASTM C1064 ASTM C1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 02/28/2005 1 2 6.00 28.27 02/28/2005 1 3 6.00 28.27 03/21/2005 1 4 6.00 28.27 03/21/2005 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 116,420 ~,120 7 114,000 I,~,030 Average 4,080 28 152,950 f 5,410 28 156,300 ~., 530 Average ~',470 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Bradley W. Hatch Repor~ Distribution: (1) Hill & Wilkinson LTD (1) Hardy McCullah/MLM Architects Inc (1) 33vlBP Consulting Engineers (1) City of Coppe[I TX (1) BCE Specialties Reviewed by: :~~rsnier re oct Re°bertpD-, R a The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use o[ the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.