Four Seasons 2R-LR050322CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94041388.0076
Service Date: February 21,2005
Client: Hill & Wilkinson LTD
Attn: Charles Hoagland
800 Klein Rd Ste 100
Plane TX 75074
'lrerracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: March 22, 2005
Project: BCE Specialties
989 West Sandy Lake Road
Coppell, TX
Project Number: 94041388
Material Information
Specified Strength: 5000 psi @ 28 Days
Batch Time: 10:21 am
Supplier: Southern Star
Truck No: 1016
Mix I.D. No.: 7503
Water Added Onsite Before Test:
Water Added Onsite After Test:
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature, O F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Plant: 66
Ticket No: 769344
0 Gallons
0 Gallons
Result
8.50
4.3
73
74
Sample Information
Sample Time: 11:00 am Date Cast: February 21,2005
Technician: Bradley W. Hatch
Weather Conditions: Clear, windy
Accumulative Yards: 10
Placement Method: Direct Discharge
Sample Locations: Bottom half of Panel No. 4
Placement Location: Panel No. 4
Specification Test Method
7-9 ASTM C143
4-6 ASTM C231
ASTM C1064
ASTM C1064
Set Specimen Diameter Area Date
No. ID (inches) (sq. inches) Tested
1 1 6.00 28.27 02/28/2005
1 2 6.00 28.27 02/28/2005
1 3 6.00 28.27 03/21/2005
1 4 6.00 28.27 03/21/2005
Age at Maximum Compressive
Test Load Strength
(days) (lbs) (psi)
7 116,420 ~,120
7 114,000 I,~,030
Average 4,080
28 152,950 f 5,410
28 156,300 ~., 530
Average ~',470
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Bradley W. Hatch
Repor~ Distribution:
(1) Hill & Wilkinson LTD
(1) Hardy McCullah/MLM Architects Inc
(1) 33vlBP Consulting Engineers
(1) City of Coppe[I TX
(1) BCE Specialties Reviewed by: :~~rsnier re oct Re°bertpD-, R a
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use o[ the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.