Loading...
RC Townhomes-LR050321ACTEC AND CONSULTING MACTEC Engineering and Consulting 2200 Gravel Drive Fort Worth, Texas 76118-7123 Tel: $17-284-7755® Fax: 817-589-1420 REPORT OF IN-PLACE DENSITY CLIENT: J.R. ROSE DEVELOPMENT 410 SPINNAKER DR. ALLEN, TX 75013 PRO'CT: RIVERCHASE TOWNHOMES ADDITIONS COPPELL PAGE 1 OF 1 PROJECTNO.: 9023912 REPORTNO.: 501769 DATE OFSERVICE: 3/21/2005 AUTHORIZATION: REPORT DATE: 3/21/2005 SERVICES: Perform in-place density and moisture content tests to determine the degree of field compaction. CONTRACTOR: UNDERGROUND UTILITIES METHOD OF TEST: DENS.Y: ASTM D2922 MOISTURE: ASTM D3017 SPECIFICATION: DENSITY: 95% MOISTURE: -2% TO +4% OF OPT. TEST OF PAVING SUBGRADE LIME TRT'D BROWN CLAY PROJECT DATA GAUGE: NA GAUGE SERIAL NO.: 27660 STANDARD COUNTS MOISTURE - CURRENTi~A PREVIOUS: NA DENSITY - CURRENT:NA PREVIOUS: NA TESTMODE: Direct Transmission PROBE DEPTH (in.): 6 MOISTURE/DENSITY RELATIONS OI'flMUM MA/CIMUM REFERENCE MOISTURE % DENSITY pcf REPORT NO 17.5 109.0 501131 TEST NO 1. 2. LOCATION STA 1+20 CENTERLINE REPORT OF TESTS FIELD OFrIMUM FIELD DENSITY MAXIMUM MOIgrURE MOISTURE (pcf~ DENSITY (%) (%} WET DRY (Pco 10.6 * 17.5 115.1 104.1 109.0 STA 2+40 EAST SIDE 11.4 * 17.5 115.7 103.9 An asterisk (*) appears next to test results which do NOT meet the project specifications as noted above. 109.0 D 99~56Sn~ Technician: Steve Campbell Report Distribution: Started: 07:00AM Stopped: 10:00AM Tim Begole, CET.