Amberpoint BP 2R-CS050331DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: PD-194R3-LI~ Amberpoint Business Park~ Lot 2R~ Block A zoning change request fi.om PD-194R2-LI, (Planned Development-194 Revision 2-Light Industrial) to PD-194R3-LI (Planned Development-194 Revision 3-Light Industrial) to allow the development of three office/warehouse buildings, totaling approximately 710,042-square feet, on 64.3 acres of property located along the south side of Sandy Lake Road, between Freeport Parkway and Northpoint Drive, at the request of Jim Gaspard, Transwestem, Commercial Services. STAFF REP.: Matt Steer PROJECT ID//PD-05-0011 DRC DA TE: MARCH31, 2005 and APRIL 7, 2005 CONTACT: Kenneth M. Grif~n, P.E., Dir. o~ En~ineerin~Public Works 972/304-3686 COMMENTSTATUS: ~PRELIMINARY FIP3~£ wTr~tzn 1. Monument signs are shown to be in the utility easements on some of the drawings. Monument signs need to be moved out of utility easements. 2. The proposed connections to Freeport Parkway are allowed provided headache bars (or equivalent measures) are installed to prevent 18-wheeler / truck traffic from accessing Freeport Pkwy. 3. The driveway at the corner of Sandy Lake Road and Freeport Parkway is too close to Freeport Parkway. The driveway should be 125'-150' from the future road. The driveway at the corner of Northpoint Drive and Sandy Lake Road is also too close to Sandy Lake Road. 4. The driveways along Northpoint Drive need to line up or be 125' aport. DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Amberpoint Business Park~ Lot 2R~ Block A, to allow the development of three office/warehouse buildings, totaling approximately 710,042-square feet on 64.3 acres of property located along the south side of Sandy Lake Road, between Freeport Parkway and Northpoint Drive, at the request of Jim Gaspard, Transwestcm Commercial Services. STAFF REP.: Matt Steer PROJECT ID# RP-05-0012 DRC DA TE: MARCH 31, 2005 and APRIL 7, 2005 CONTACT: Kenneth M. Gri~n, P.E., Dir. o[ En~ineerin~ublic Works 972/304-3686 COMMENT STATUS: ,,/PRELIMINARY F!?L~L ~ Plat Provide minimum 20' x 20' casements in the locations of the DDC's and water_meters. C3.01 The drainage information will be evaluated during the plan review process. C6.01 1. Utility easements are needed around DDC's and domestic/irrigation meters. There appears to be a cross-connection where the tie-in is made to the 8" water line at the north end of Northpoint Drive. Be sure that the fire line is served from the main after the DDC. The irrigation meter at the south end of the property is shown to be tied-in to the 8" fire line instcad of the Ex. 8" water line as is called out. The irrigation meter should be served from the existing 8" line. 4. The maximum allowable spacing between fire hydrants is 300'. Some of the hydrants shown on the plans exceed this maximum. 5. Show the location of the fire department connections on the drawing. 6. The Proposed Sanitary Sewer Layout Note should meet the Building Code. Additional comments may be generated upon detailed Engineering review.