Four Seasons 2R-LR050330CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94041388.0082 Service Date: March 1, 2005 Client: Hill & Wilkinson LTD Attn: Charles Hoagiand 800 Klein Rd Ste 100 Plane TX 75074 Report Date: p roj~il~g'~ecialties 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 March 30, 2005 989 West Sandy Lake Roa~ Coppell, TX Project Number: 94041388 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 8:38 am Plant: 27 Supplier: Southern Star Truck No: 1015 Ticket No: 764200 Mix I.D. No.: 7752 WaterAdded Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 5.50 Air Content, %: 4.5 Concrete Temperature,O F: 54 Ambient Temperature, o F: 45 Plastic Unit Weight, pcf: Laboratory Test Data Sample Information Sample Time: 9:10am Date Cast: March 1, 2005 Technician: Michael W. Whyman Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Pump Sample Locations: NW corner adjacent Sandy Lake Rd. Placement Location: Paving, Sandy Lake Rd. Entrance Specification Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 03/08/2005 1 2 6.00 28.27 03/08/2005 1 3 6.00 28.27 03/29/2005 1 4 6.00 28.27 03/29/2005 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 123,730 4,380 7 119,860 4,240 Average 4,310 28 154,030 5,450 28 172,950 6,120 Average 5,790 Comments: Not tested for plastic unit weight. ServiceS~~amples.- Obtain samples of fresh concrete at the placement~ ~ ?l°cati¢ orm required~ field~, tests¢~and cast compressive Technician: Michael W. Whyman Repeal Distribution: (1) Hill & Wilkinson LTD (I) Hardy rv~Cullah/MLM Architects [nc (1) TMBP Consulting Engineers (1) City of Coppell TX (1) BCE Specialties Reviewed by: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repo~t is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.