Coppell Trade-LR050328FIELD DENSITY TESTING Report Number: 94051081.0014 Service Date: March 15, 2005 'lrerracan 890'i Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: March 28, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Protect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pct} (%) (% compaction) 1. 510810003 ASTM D 698 Tan & brown clayey sand 2. 510810005 ASTM D 698 Light brown silty clay w/gravel 3. 510810005 ASTM D 698 Light brown silty clay w/gravel Field Test Data Probe Test LiftJ Mat. Depth No. Test Location Elevation No. (inches) Building C, See Attached Sketch 7 75' S & 15' W from NE corner 7.5' BFP 1 6 8 60' S & 30' W from NE corner 8' BFP 1 6 9 Bldg. Center Line, 5' S from N edge 9.5' BFP 1 6 10 60' S & 30' E from NW corner 12' BFP 1 6 12.2 117.0 >/= Opt. 95 15.4 109.8 ,~ t~ 15.4 109.8 -1/+3 95 Water Dry Unit Dry Unit Content Weight Weight (%) (pc0 (% compaction) 16.1 115.1 98 15.4 114.2 98 18.0 117.6 100+ 15.8 112.9 96 11 100' S & 50' W from NE corner 6.5' BFP 2 6 ~ 104.8 95 12 N side Fire Lane, 20' N & 40' W of NE 4'BFP 3 6 (~0~.8 .~) 104.6 95 corner Datum: BFP = Below finished pad Comments: An asterisk (*) appears next to test results which do NOT meet the project,specifications. Services- Perform in-place density and mo[stura content ,gree of compaction ~d material moisture condition. Field Test Method:ASTM D2922, ASTM D3017  determine dE Gauge iD: 32769 Technician: Michael E. Odom Field Results Repoded To: Charlie & John w/Metroplex Report Distribution: (1) Coppell Trade Center LP (1) Merrim~n Assoc Inc (1) Pri~chard Associates [nc Reviewed by: . (1) City of Coppell TX Robert D. Rav. S,L~. (1) City of Coppel[ TX Senior Pro~r'fvlanager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of I 03/10/2005 / C2+36k--. C0+49 100 Foot Grid 0 150 3O0 Cuts & Fills After Stripping to Proposed Subgrade Elevation HBO / TERRACON REPORT NO. q¥¢~/o~'/,