Loading...
Four Seasons 2R-LR050407CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94041388.0093 Service Date: March 30, 2005 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Hill & Wilkinson LTD Attn: Charles Hoagland 800 Klein Rd Ste 100 Piano TX 75074 Report Date: A~ Project: BCE Spec[alt'y 989 West Sandy Lake Road Coppell, TX Project Number: 94041388 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:49 am Plant: 29 Supplier: Southern Star Truck No: 80 Ticket No: 782944 Mix I.D. No.: 9349 Water Added Onsite Before Test: 20 Gallons Water Added Onsite After Test: Field Test Data Test 0 Gallons Result Slump, inches: 6.50 Air Content, %: 1.5 Concrete Temperature? F: 75 Ambient Temperature, o F: 74 Plastic Unit Weight, pcf: Laboratory Test Data Sample Information Sample Time: 7:45 am Date Cast: March 30, 2005 Technician: Robed C. McKee Weather Conditions: Cool, sunny Accumulative Yards: 20 Placement Method: Bucket Sample Locations: E/12.5 Placement Location: Slab Leaveouts excluding N12.5-A-3 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 3 4 Specification 3-5 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 04/06/2005 7 120,540 / 4,260 04/06/2005 7 119,120 L4,21o_ Average 4,240 04/27/2005 28 04/27/2005 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh strength samples. placement locations, perform required field tests and cast compressive Technician: Robed C. McKee Repod Distribution: /.~/ .,~',/.~ ~ (1) Hill & Wilkinson LTD (1) Ciiy o[ Coppell TX ffj ~ ~.~/'J ~ (1) HardyMcCullah/MLMArchitectslnc (l) BCESpeciallies Reviewed by: ,/~ c.~_.~(/~/~ ,~ (1) TMBP Consulting Engineers ~ ~ ~' ..... (1) ciiy of Coppel[ TX I~oDer~ L~. ~ay, ~.c. ~ Senior Project Manag~:~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of th~-client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1