Loading...
Coppell Trade-LR050414FIELD DENSITY TESTING ~eport Number: 94051081.0025 Service Date: Mamh 30, 2005 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 'll'erracan 8901 Carpenter Frw,/, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 14, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Prelect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf') (%) (% compaction) 1. 510810005 ASTM D 698 Light brown silty clay w/gravel 2. 510810008 ASTM D 698 Tan clayey sand 3. 510810002 ASTM D 698 Dark reddish brown sandy clay Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) Pad C 66 300' S & 50' E of NW corner At Grade 1 6 67 375' S & 50' E of NW corner 2.5' BFG 1 6 68 425' S at center line 2' BFG 1 6 69 475' S at center line 2.5' BFG 1 6 70 375' S & 25' E of NW corner 1.5' BFG 2 6 71 375' S at center line .5' BFG 2 6 72 400' S at center line 2.5' BFG 2 6 73 400' S & 20' W of NE corner 2.5' BFG 2 6 74 375' S & 50' E of NW corner At Grade 2 6 75 400' S & 60' E of NW corner 2' BFG 2 6 76 500' S at center line 4.5' BFG 2 6 77 525' S at center line 4.5' BFG 2 6 78 500' S at center line 4.5' BFG 2 6 79 550' S at center line 4.5 BFG 3 6 80 475' S & 50' E of center line 4' BFG 2 6 81 575' S & 50' W of center line 4' BFG 1 6 15.4 109.8 >/=+2 93 11.5 117.5 >/=+2 93 15.2 106.2 >/=+2 93 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) 17.7 102.8 94 18.9 103.7 94 17.9 102.7 94 19.4 104.7 95 15.3 110.1 94 15.1 111.1 95 13.8 111.1 95 14.3 110.7 94 16.7 108.9 93 16.4 109.1 93 16.5 111.9 95 15.1 112.1 95 14.6 109.8 93 19.7 100.7 95 15.8 110.7 94 18.1 103.4 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wriffen consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 ~.-~o~.~,.~.~ .FIELD DENSITY TESTING Client:Coppell Trade Center LP .Field Test Data Probe Test Lift/ Mat, Depth No. Test Location Elevation No. (inches) 82 575' S at center line 3.5' BFG 1 6 83 550' S at center line 3.5' BFG 3 6 84 475' S at center line 3' BFG 3 6 85 575' S & 20' W of E edge 3' BFG 3 6 86 550' S & 40' W of E edge 2.5' BEG 3 6 87 525' S & 75' E of W edge 2' BFG 2 6 88 475' S at center line 1.5' BFG 2 6 89 500' S at center line 1.5' BFG 2 6 90 575' S at center line .5' BFG 2 6 91 575' S at center line At Grade 2 6 'll'erracan Project Number:94051081 Report Number: 94051081.0025 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) 18,7 102.9 94 18.4 99.8 94 17.4 100.8 95 17.8 100.1 94 18.0 100.0 ( 94 14.7 109,8 93 13.7 111.7 95 13.7 112.1 95 14.1 110.4 94 15.9 110.4 94 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition, Field Test Method~ASTM D2922, ASTM D3017 Technician: Michael E. Odom Field Results Reported To: Charlie in Metroplex Report Distribution: (1) Coppe~l Trade Center LP (1) Merriman Assoc Inc //~ ' . (1) Pritchard Associates Inc (1) McFadden & Miller Reviewed by: (1) City of Coppell TX Robert D. Ray, S.E.y (1) City of Coppell TX Senior Project M.~Jer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use~,f the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2