Coppell Trade-LR050409FIELD DENSITY TESTING Report Number: 94051081.0026 Service Date: Mamh 31,2005 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 'lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 09, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Optimum Max. Lab Water Dry Unit Content Weight (%) (pc0 Proiect Requirements Water Content Minimum Dry Range Unit Weight (%) (% compaction) 1. 510810005 ASTM D 698 Light brown silty clay w/gravel 2. 510810002 ASTM D 698 Dark reddish brown sandy clay 3. 510810003 ASTM D 698 Tan & brown clayey sand Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) 98 99 100 101 102 103 104 Datum: Site Grading 92 30' N & 75' E of SE comer of bldg. 8' BFG 1 6 93 220' N & 50' E of SE corner of bldg. 7.5' BFG 2 6 94 175' N & 30' E of SE corner of bldg. 7.5' BFG 3 6 95 125' N & 20' W of SE comer of bldg. 6.5' BFG 3 6 96 70' N & 60' W of SE corner of bldg. 4.5' BFG 1 6 97 40' N & 120' W of SE corner of bldg. 7.5' BFG 2 6 30' S & 60' E of SW corner of bldg, 9' BFG 1 6 330' N & 70' E of SE corner of bldg. 8' BFG 1 6 275' N & 20' W of SE corner of bldg. 8' BFG 2 6 220' N & 40' W of SE corner of bldg. 8' BFG 1 6 180' N & 80' W of SE corner of bldg. 8'BFG 2 6 120' N & 100' W of SE corner of bldg. 8'BFG 1 6 90' N & 110' W of SE comer of bldg. 8'BFG 1 6 BFG = Below final grade 15.4 15.2 12.2 109.8 -1/+3 95 106.2 -1/+3 95 117.0 -1/+3 95 Water Dry Unit Dry Unit Content Weight Weight (%) (pcO (% compaction) 16.4 104.5 /95 18.2 102.0 96 15.0 111.9 6 15.9 * 110.9 95 14.8 104.2 95 15.1 104.7 99 16.9 106.4 97 18.0 105.1 96 15.1 104.4 98 14.2 * 105.5 96 19.5 * 104.5 98 18.2 105.4 96 17.2 105.4 96 Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wriffen consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. FIELD DENSITY TESTING client:coppell Trade Center LP Comments (cont'd): 'lrerracan Project Number:94051081 Report Number: 94051081.0026 NOTE: *Recommend Passing. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Technician: Michael E. Odom Field Results Reported To: Charlie w/Metroplex Report Distribution: (1) Coppell Trade Cenler LP (1) Pdlchard Associates Inc (1) City of Coppell TX (1) City of Coppell TX (1) Merriman Assoc inc (1) McFadden &Miiler Robert D. Ray, S.E.T.~,~'' Senior Project Man~.,~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. FIELD DENSITY TESTING ~,eport Number: 94051081.0026A Service Date: March 31, 2005 Client: Coppell Trade Center LP Attn: Al Sorrets 5055 Keller Springs Rd Ste 300 Addison TX 75001 'll'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) §30-1010 Report Date: April 09, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Optimum Max. Lab Water Dry Unit Content Weight (%) (pcf) Proiect Requirements Water Content Minimum Dry Range Unit Weight (%) (% compaction) 1. 510810002 ASTM D 698 2. 510810005 ASTM D 698 3. 510810008 ASTM D 698 Dark reddish brown sandy clay Light brown silty clay w/gravel Tan clayey sand .Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) Building C Pad 105 525' S & 20' E of NW comer 1.5' BEG 3 6 106 550' S & 20' E of NW corner 1.5' BEG 3 6 107 575' S & 20' E of NW corner 1' BEG 3 6 108 525' S & 75' E of NW corner .50' BEG 3 6 109 550' S & 75' E of NW comer 1'BEG 3 6 110 575' S & 75' E of NW corner 1.5' BEG 2 6 111 525' S & 125' E of NW comer .50' BEG 1 6 112 550' S & 125' E of NW corner 1'BEG 2 6 113 575' S & 125' E of NW corner 1'BEG 2 6 114 525' S & 175' E of NW corner .50' BEG 2 6 115 550' S & 175' E of NW corner 1'BEG 1 6 116 575' S & 175' E of NW corner 1'BEG 2 6 117 560' S & 60' E of NW comer .50' BEG 1 6 118 560' S at Center Line Final 1 6 119 560' S & 175' W of NW corner Finat 2 6 120 610' S at Center Line Final 2 6 15.2 106.2 >/= +2 93 15.4 109.8 >/= +2 93 11.5 117.5 >/= +2 93 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) 13.9 109.5 93 14.7 112.1 95 14.7 111.1 / 95 13.6 110.9 / 94 14.4 109.5 93 17.6 102.8 94 17.7 100.7 95 19.1 102.9 94 19.4 103.7 94 18.2 103.9 95 18.1 100.9 95 17.9 102.8 94 17.8 101.1 95 19.0 101.1 95 17.9 102.0 [ 93 17.8 104.0 ~. 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein ara only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ,FIELD DENSITY TESTING Client:Coppell Trade Center LP Field Test Data Test No. Test Location 121 650'S 122 680'S 123 610'S 124 650'S 125 675'S 128 610'S 127 650'S 128 675'S 129 680'S 130 670'S 131 700'S 132 700'S 133 700'S 134 700'S 135 700'S 136 700'S 137 750'S 138 750'S 139 750'S 140 750'S 141 750'S 142 750'S 143 750'S Datum: at Center Line at Center Line & 150' W of NW corner & 150' W of NW corner & 150' W of NW comer & 20' W of NW corner & 50' W of NW corner & 70' W of NW corner & 10' W of NW corner & 70' W of NW corner from N end at Center Line & 20' E of Center Line & 20' W of Center Line & 60' E of Center Line & 60' W of Center Line & 80' W of Center Line at Center Line & 30' E of Center Line & 60' E of Center Line & 90' E of Center Line & 30' W of Center Line & 60' W of Center Line & 90' W of Center Line BEG = Below existing grade 'il'erracan Project Number:94051081 Report Number: 94051081.0026A Probe Water Dry Unit Dry Unit Lift/ Mat. Depth Content Weight Weight Elevation No. (inches) (%) (pcf) (% compaction) .50' BEG 2 6 1' BEG 2 6 18.7 .50' BEG 2 6 17,7 1' BEG 2 6 17.7 1' BEG 1 6 18.1 Final 1 6 18.6 1' BEG 3 6 13.8 1' BEG 3 6 14.1 1' BEG 3 6 14.3 1' BEG 3 6 15.0 4.5' BEG 2 6 17,4 4.5' BEG 1 6 17.4 4.5' BEG 1 6 18.4 4' BEG 1 6 19,7 4' BEG 1 6 19.1 4' BEG 2 6 17.7 3.5' BEG 1 6 19.1 3.5' BEG 1 6 18.4 3.5' BEG 1 6 19,4 3,5' BEG 1 6 18.2 3' BEG 1 6 18.7 3' BEG 2 6 17.5 3' BEG 2 6 17.9 18.4 103.7 94 102,9 / 94 104.2 95 103.2 94 100.9 95 101.1 95 110.8 94 111.1 95 111.7 95 109.8 93 104.1 95 100.9 95 102.7 97 100.9 95 100.7 95 103.! 95 101.' 95 101.~ 96 100.~ 95 lOOJ 95 101.9 96 104.7 ~ 95 103.8 95 Comments: Test results on this report meet project specification. Services - Perform in-place moisture and density retests as requested or as required by the project specifications to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Technician: Michael E, edom Report Distribution: (1) Coppell Trade Center LP (1) Merriman Assoc Inc (1) Pritchard Associates Inc (1) McFadden & Miller Reviewed by: (1) City of Coppell 7'X (1) City of Copperl TX r~;ooer~ L~. y, . . Senior Project Manage~,~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This raped is exclusively for the use of the~Jient indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarity indicative of the properties of other apparently similar or identical materials. Page 2 of 2