Four Seasons 2R-LR050412CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94041388.0097
Service Date: April 4, 2005
Client: Hill & Wilkinson LTD
Attn: Charles Hoagland
800 Klein Rd Ste 100
Piano TX 75074
Material Information
Specified Strength: 4000 psi @ 28 Days
Batch Time: 7:00 am Plant: 27
Supplier: Southern Star
Truck No: 1815 Ticket No: 773595
Coppell, TX
Project Number: 94041388
Sam le lnformatio~
Sample Time: 7:50 am
Technician: Robert C. McKee
Weather Conditions:
Accumulative Yards: 20
Placement Method: Pump
ll'erracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: Apr,,,~,,,l,~2005
Project: BCE Specialties/
989 West Sandy Lake Road
Date Cast: April 4, 2005
Mix I.D. No.: 9349
Water Added Onsite Before Test:
Water Added Onsite After Test:
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
9 Gallons
0 Gallons
Sample Locations: Nll.0
Placement Location: interior Slab Leaveout, N12.5-N3.0
Result Specification Test Method
4.75 3-5 ASTM C143
2.3 ASTM C231
68 ASTM C1064
61 ASTM Cl 064
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
1 1 6.00 28.27 04/11/2005 7 114,950 4,070
1 2 6.00 28.27 04/11/2005 7 119,980 4,240
Average 4,'160
1 3 05102/2005 28
1 4 05/02/2005 28
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Robert C. McKee
Report Distribution:
(1) HiI~ & Wilkinson LTD
(1) Hardy McCullah/MLM Architects Inc
(1) TMBP Consulting Engineers
(1) city of Coppell TX
(1) City of Coppelt TX
(1) BCE Specialties
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the Iccation(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials. Page 1 of 1