Loading...
Four Seasons 2R-LR050413CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94041388.0098 Service Date: April 5, 2005 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Hill & Wilkinson LTD Attn: Charles Hoagland 800 Klein Rd Ste 100 Piano TX 75074 Report Date: April 13, 2005 Project: BCE Specialties 989 West Sandy Lake Road Coppell, TX Project Number: 94041388 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: Supplier: Truck No: Mix I.D. No.: Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Sample Information Sample Time: Date Cast: April 5, 2005 Technician: Contractor Made Weather Conditions: Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 1 4 Placement Method: Sample Locations: See Placement Location Placement Location: Misc. Sidewalks along S and E side of Main bldg. Result Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 04/12/2005 7 89,530 3,170 04/12/2005 7 83,710 2,960 Average 3,070 05103/2005 28 05/03/2005 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement rocations, perform required field tests and cast compressive strength samples. Technician: Robert D. Ray Report Distribution: (1) Hill & Wilkinson LTD (1) City of Coppell TX (1) Hardy McCu~Iah/MLM Architects Inc (1) BCE Specialties Reviewed by' (1) TMBP Consulting Engineers ' (1) Cily of Coppell TX Robert D. Ray, S.E.T. Senior Project Manag~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of t~e client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.