Coppell Trade-LR050411 (2)FIELD DENSITY TESTING Report Number: 94051081.0027 Service Date: April 1,2005 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 'lrerracan 8901 Carpenter Fr~vy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 11,..~.?.005 Pro?ct: Coppell T~ NWC sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pc0 (%) (% compaction) 1. 510810005 2. 510810002 3. 510810003 4. 510810008 Field Test Data Test No. ASTM D 698 ASTM D 698 ASTM D 698 ASTM D 698 Light brown silty clay w/gravel 15.4 Dark reddish brown sandy clay 15.2 Tan & brown clayey sand .. ~/-~v 12.2 Tan clayey sand ~ Lift/I Mat/~ Test Location Elevation Not" (inches) 109.8 >/= +2 93 106.2 >/= +2 93 117,0 >/= +2 93 117.5 >/= +2 93 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) Building C 144 800' S from N end at Center Line 4' BEG 1 6 17.4 105.2 145 800' S & 20' E of Center Line 4' BEG 1 6 19.4 104.3 146 800' S & 20' W of Center Line 4'BEG 1 6 17.2 * 104.5 147 800' S & 60' E of Center Line 3.5' BEG 1 6 18,4 105.3 148 800' S & 60' W of Center Line 3.5' BEG 1 6 17.7 105.5 149 800' S & 80' W of Center Line 3.5' BEG 1 6 18.1 105.0 150 825' S at Center Line 3' BEG 1 6 17.7 104.6 151 825' S & 30' E of Center Line 3' BEG 3 6 14.8 112.0 152 825' S & 60' E of Center Line 3'BEG 3 6 14.7 111.0 153 825' S & 90' E of Center Line 3' BEG 2 6 17.7 101.0 154 825' S & 30' W of Center Line 2.5' BEG 2 6 17.9 100.8 155 825' S & 60' W of Center Line 2.5' BEG 1 6 18,2 102.7 156 825' S & 90' W of Center Line 2.5' BEG 2 6 17,8 101.1 157 850' S from N end 3.5' BEG 2 6 17.5 102.9 158 850' S & 30' E of Center Line 3.5' BEG 100.8 96 95 95 96 96 96 95 96 95 95 95 94 95 97 95 The tests were pen'ormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and ara not necessarily indicative of the properties of other apparently similar or identical materials. F ELD DENSITY TESTING client:Coppell Trade Center LP 'li'erracon Project Number:94051081 Report Number: 94051081.0027 .Field Test Data Test No. Test Location Probe Water Dry Unit Lift/ Mat. Depth Content Weight Elevation No. (inches) (%) (pc0 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 850' S & 30' W of Center Line 850' S & 70' E of Center Line 850' S & 70' W of Center Line 850' S & 90' W of Center Line 875' S at Center Line 875' S & 40' E of Center Line 875' S & 80' E of Center Line 875' S & 90' E of Center Line 875' S & 40' W of Center Line 875' S & 80' W of Center Line 875' S & 90' W of Center Line 900' S from N end 900' S & 10' E of Center Line 900' S & 10' W of Center Line 900' S & 50' E of Center Line 900' S & 50' W of Center Line 900' S & 80' W of Center Line 925' S at Center Line 925' S & 70' E of Center Line Retest of #177, dated 04/01/05 925' S & 90' E of Center Line 925' S & 10' W of Center Line 925' S & 40' W of Center Line 925' S & 80' W of Center Line 950' S fmm N end 950' S & 40' E of Center Line 950' S & 60' W of Center Line 950' S & 80' E of Center Line 950' S & 90' W of Center Line 950' s & 100' w of Center Line 3.5' BEG 1 6 18.0 101.9 3' BEG 2 6 19.0 102.8 3' BEG 2 6 19.1 103.6 3' BEG 2 6 18.0 104.0 2.5' BEG 2 6 17.8 102.7 2.5' BEG 2 6 17.8 101.1 2.5' BEG 1 6 17.7 104.2 2.5' BEG 4 6 13.9 110.7 2'BEG 4 6 13.7 110.6 2'BEG 4 6 14.1 111.1 2' BEG 2 6 18.0 102.9 3'BEG 3 6 14.7 110.2 3' BEG 3 6 14.2 110.7 3' BEG 3 6 14.8 111.1 2.5' BEG 3 6 14.9 110.0 2.5' BEG 3 6 14.1 * 111.4 2.5' BEG 1 6 17.9 104.7 2' BEG 1 6 17.7 105.1 2' BEG 1 6 14.9 * 105.2 3 6 15.1 108.9 2' BEG 1 6 18.1 104.8 1.5' BEG 2 6 19,1 100.9 1.5' BEG 2 6 17.9 101.1 1.5' BEG 2 6 17.9 100.8 2.5' BEG 4 6 15.1 109.7 2.5' BEG 4 6 14.7 111.6 2.5' BEG 4 6 14.5 110.9 2' BEG 4 6 13.9 110.8 2' BEG 1 6 17.9 103.2 2' BEG 1 6 18.0 104.0 Dry Unit Weight (% ¢ 3mpaction) 93 97 98 98 97 95 95 94 94 95 97 94 95 95 94 95 95 96 96 93 95 95 95 95 93 95 94 94 94 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ,FIELD DENSITY TESTING Client: coppell Trade Center LP ll'err can Project Number:94051081 Report Number: 94051081.0027 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pc~) (% compaction) 189 975' S at Center Line 1.5' BEG 1 6 18.8 103.9 95 190 975' S & 20' E of Center Line 1.5' BEG 2 6 17.7 101.1 95 191 975' S & 50' E of Center Line 1.5' BEG 2 6 17.7 100.4 95 192 975' S & 80' E of Center Line 1.5' BEG 1 6 18.2 106.0 97 193 975' S & 20' W of Center Line 1' BEG 1 6 17.4 104.0 95 194 975' S & 50' W of Center Line 1' BEG 1 6 18.1 103.8 95 195 975' S & 80' W of Center Line 1'BEG 2 6 18.9 101.0 95 Datum: BEG = Below existing grade Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. NOTE: *Recommend Passing. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Technician: Michael E. Odom (1) Coppe[I Trade Center LP (1) Merriman Assoc Inc (1) Pritchard Associates Inc (1) McFadden & Miller Reviewed by: (1) City of Coppell TX (1) City of Coppell TX The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.