Coppell Trade-LR050418FIELD DENSITY TESTING 'Report Number: 94051081,0031 Service Date: April 5, 2005 'lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: April 18, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pc0 (%) (% compaction) 1.510810005 ASTM D 698 2.510810003 ASTM D 698 3.510810002 ASTM D 696 4.510810007 ASTM D 698 Field Test Data Test No. Light brown silty clay w/gravel Tan & brown clayey sand Dark reddish brown sandy clay Brown clay w/sand & gravel Lift/ Mat. Test Location Elevation Site Grading, See attached sketch 274 100' N & 90' W of SE corner of Building 503.5' B 275 150' N & 120' W of SE corner of Building 503.5' B 276 200' N & 150' W of SE comer of Building 503.5' B 277 300' N & 180' W of SE corner of Building 503.5' B 278 400' N & 180' W of SE corner of Building 503.5' B 279 475' N & 160' W of SE comer of Building 503.5' B 280 50' N & 170' W of SE corner of Building 503.5' B 281 100' N & 170' W of SE corner of Building 503.5' B 15.4 109.8 -1/+3 12.2 117.0 -1/+3 15.2 106.2 -1/+3 20,7 101.2 -1/+3 Probe Water Dry Unit Depth Content Weight No. (inches) (%) (pcf) I 6 18.4 106.8 1 6 14.3 * 108.7 1 6 14.7 109.8 3 6 16.6 101.6 3 6 15.8 103.2 2 6 15.1 110.7 I 6 16.0 107.8 3 6 15.0 111.6 95 95 95 95 Dry Unit Weight (% con laction) 97 99 100 96 97 95 98 ,100+ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wdtten consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. FIELD DENSITY TESTING Client: coppell Trade Center LP 'lrerracon Project Number:94051081 Report Number: 94051081.0031 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pc0 (% compaction) 282 150' N & 170' W of SE corner of Building 503.5' 3 6 18.1 101.9 96 B 283 200' N & 170' W of SE corner of Building 503.5' 3 6 17.9 101.7 96 B 284 250' N & 160' W of SE corner of Building 503.5' 4 6 23.6 98.8 98 B 285 300' N & 80' W of SE corner of Building 503.5' 4 6 23.3 101.7 100 B 286 350' N & 80' W of SE corner of Building 503.5' 1 6 18.3 106.7 97 B 287 240' N & 60' W of SE corner of Building 503.5' 1 6 17.4 109,5 100 B 288 160' N & 60' W of SE corner of Building 503.5' 2 6 15.2 110.9 95 289 70' N & 70' W of SE corner of Building B 503.5' 2 6 14.9 113.2 97 290 40' N & 120' W of SE corner of Building 503.5' 2 6 15.1 112.2 96 B 291 260' N & 100' W of SE corner of Building 503.5' 1 6 16.2 107.6 98 B 292 360' N & 110' W of SE comer of Building 503.5' 1 6 16,2 105.9 96 B 293 430' N & 70' W of SE corner of Building 503.5' 1 6 17.4 106.7 97 B 294 480' N & 60' W of SE corner of Building 503.5' 1 6 17.1 106.1 97 B Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. NOTE: Recommend passing. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Technician: Michael E. Odom Report Distribution: ,/~ (1) Coppell Trade Center LP (1) Merriman Assoc Inc ~/ ~' ~ .~,,,~ J (1) Pdtchard Associateslnc (1) McFadden &Miller Reviewed by: ~ ~ {./ ~ ~ (1) City of Coppell TX Robert D. Ray, S.E.T. (1) Cdy of Coppell TX Senior Project Manag~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of ,,f,~. indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only a~plicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. FIELD DENSITY TESTING Report Number: 94051081.0029A Service Date: April 4, 2005 'lrerracan 8901 Carpenter Fn,vy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: April 18, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. 510810002 2. 510810005 3.510810008 4. 510810004 Field Test Data Test No. Site Grading 261 262 263 264 265 266 267 268 ASTM D 698 ASTM D 698 ASTM D 698 ASTM D 698 Dark reddish brown sandy clay Light brown silty clay w/gravel Tan clayey sand Gray clay w/gravel Lift/ Mat. Test Location Elevation No. 475' N of SW corner of Building [] and 7' BTG 10'E 440' N of SW corner of Building [] and 6' BTG 30'E 400' N of SW corner of Building [] and 5' BTG 50' E 370' N of SW corner of Building B and 4' BTG 70'E 340' N of SW corner of Building [] and 7' BTG 90'E 300' N of SW corner of Building [] and 6' BTG 100' E 275' N of SW corner of Building [] and 7' BTG 120' E 225' N of SW corner of Building [] and 6' BTG 140'E 15.2 106.2 -1/+3 95 15.4 109.8 -1/+3 95 11.5 117.5 ~1/+3 95 18.0 103.0 -1/+3 95 Probe Water Dry Unit Dry Unit Depth Content Weight Weight (inches) (%) (pcf) (% compaction) 4 6 18.0 101.1 98 4 6 19.1 100.1 97 2 6 14.3 * 106.9 97 3 6 13.4 112.3 96 2 6 17,5 107.2 98 3 6 14.4 111.9 95 3 6 14.5 112.8 96 2 6 16.7 107.0 97 The tests were performed in general accordance with applicable ASTM, AAS HTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the proper[les of other apparently similar or identical materials. Fage 1 of 2 FIELD DENSITY TESTING client:coppell Trade Center LP lrerracon Project Number:94051081 Report Number: 94051081.0029A Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pct} (% compaction) 269 175' N of SW corner of Building B and 5' BTG 1 6 14.2 104.4 98 170'E 270 125' N of SW corner of Building B and 4' BTG 1 6 14.8 101.4 95 200' E 271 75' N of SW corner of Building B and 40' 3.5' BTG 2 6 17.3 109.5 100 E 272 50' N of SW corner of Building B and 80' 6' BTG 2 6 18.2 106.9 97 E 273 25' N of SW corner of Building B and 7' BTG 4 6 19.7 101.7 99 120' E Datum: BTG= Below top of ground Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. NOTE: Recommend passing. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Technician: Michael E. Odom (1) Coppell Trade Center LP (1) Merriman Assoc Inc (1) Pritchard Associates Inc (1) McFadden & Miller Reviewed by: (1) City of Coppell TX (1) City of Coppell TX Senior Project Manage~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. FIEL'D DENSITY TESTING Report Number: 94051081.0029 Service Date: April 4, 2005 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 18, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. 510810002 ASTM D 698 Dark reddish brown sandy clay 15.2 106.2 >/=+2 93 2.510810005 ASTM D 698 Light brown silty clay w/gravel 15.4 109.8 >/=+2 93 3.510810008 ASTM D 698 Tan clayey sand 11.5 117.5 >/=+2 93 .Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) Building C Pad 235 850' S from N end at center line 1.5' BEG 1 6 17.9 101.8 96 236 850' S from N end at center line 1' BEG 1 6 18.1 101.9 96 237 850' S from N end at center line 1.5' BEG 2 6 18.0 102.9 94 238 850' S from N end at center line 1' BEG 2 6 18.4 102.4 93 239 850' S from N end at center line 1.5' BEG 3 6 14.6 109.7 93 240 850' S from N end at center line 1' BEG 1 6 17.4 102.0 96 241 900' S from N end at center line 1' BEG 3 6 14.4 109.8 93 242 900' S from N end at center line .5' BEG 3 6 13.9 110.7 94 243 900' S from N end at center line 1' BEG 1 6 17.9 102.1 96 244 900' S from N end at center line .5' BEG 2 6 18.4 103.1 94 245 900' S from N end at center line 1' BEG I 6 18.2 102.1 96 246 900' S from N end at center line ,5' BEG 3 6 14.1 110.1 94 247 900' S from N end at center line 1' BEG 3 6 13,8 111.1 95 248 875' S from N end and 90' W of center .5' BEG I 6 17.7 102.4 96 line 249 900' S from'N end and 70 E of center line .5' BEG 3 6 15.0 110.8 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. FIELD DENSITY TESTING Client: Coppell Trade Center LP 'lrerracan Project Number:94051081 Report Number: 94051081.0029 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) 250 925' S from N end and 50' W of center .5' BEG 3 6 14.7 111.1 95 line 251 950' S from N end at center line .5' BEG 3 6 14.0 109.9 94 252 975' S from N end and 90' W of center .5' BEG 3 6 13.7 109,2 93 line 253 875' S from N end and 70' E of center line .5' BEG 2 6 17.7 104.1 95 254 900' S from N end and 50' W of center .5' BEG 2 6 17.8 103.9 95 line 255 925' S from N end at center line .5' BEG 2 6 18.1 105.0 96 256 975' S from N end at center line .5' BEG 1 6 17.9 101.1 95 257 875' S from N end and 10' E of center line .5' BEG I 6 17.6 102.1 96 258 900' S from N end and 70' W of center .5' BEG 3 6 13.9 110.7 94 line 259 925' S from N end and 20' E of center line ,5' BEG 1 6 19.4 101.4 95 260 950' from N end and 80' W of center line .5' BEG 2 6 18.4 103.7 94 Datum: BEG= Below existing grade Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Technician: Michael E. Odom Report Distribution: (1) Coppell Trade Center LP (1) Merriman Assoc Inc (1 } Pritchard Associates Inc (1) McFadden & Mitler Reviewed by: (1) City of Coppell TX Robert D. Ray, S.E.T. (1) City of Coppell TX Senior Project Manager The tests were pedormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. FIELD DENSITY TESTING Report Number: 94051081.0028 Service Date: April 2, 2005 'll'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: April 18, 2005 p r oj e ct~_..~ p e !.1. T__r~_d. ~_~C_e nte r ~ NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Ma terial In formation Material Laboratory No. Test Method Description and Classification Lab Test Data Optimum Max. Lab Water Dry Unit Content Weight (%) (pcf) Project Requirements Water Content Minimum Dry Range Unit Weight (%) (% compaction) 1. 510810008 ASTM D 698 Tan clayey sand 11.5 117.5 >/=+2 2. 510810005 ASTM D 698 Light brown silty clay w/gravel 15.4 109.8 >/=+2 3. 510810002 ASTM D 698 Dark reddish brown sandy clay 15.2 106.2 >/=+2 Field Test Data Probe Water Dry Unit Test Lift/ Mat. Depth Content Weight No. Test Location Elevation No. (inches) (%) (pc0 196 825' S from N end at center line 2.5' BEG 1 6 14.5 109.7 197 825' S from N end & 50' W of center line 2.5' BEG 1 6 15,3 111.9 198 825' S from N end & 90' W of center line 2.5' BEG 1 6 16.1 112.1 199 825' S from N end & 50' E of center line 2' BEG 1 6 16.2 109.0 200 825' S from N end & 90' E of center line 2' BEG 1 6 16.5 108.8 201 840' S from N end &10' W of center line 2' BEG 1 6 13.9 110.9 202 850' S from N end & 20' W of center line 2.5' BEG 1 6 15.7 111.0 203 850' S from N end & 60' W of center line 2.5' BEG 2 6 17.8 104.7 204 850' S from N end & 30' E of center line 2.5' BEG 2 6 18.8 102.7 205 850' S from N end & 70' E of center line 2.5' BEG 2 6 19.3 103.3 206 850' S from N end & 70' W of center line 2'BEG 2 6 17.7 102.7 207 850' S from N end & 30' E of center line 2' BEG 2 6 17,7 103.1 208 850' S from N end & 90' E of center line 2' BEG 2 6 18.4 104.4 209 875' S from N end at center line 2' BEG 3 6 18.3 99.7 210 875' S from N end & 20' E of center line 2' BEG 3 6 17.7 100.7 211 875' S from N end & 20' W of center line 2'BEG 3 6 17.8 100.1 212 875' S from N end & 60' E of center line 1.5'BEG ,3 18.0 100.0 93 93 93 Dry Unit Weight (% ;ompaction) 93 95 95 93 93 94 94 95 94 94 94 94 95 ~5 ~4 The tests were performed in generat accordance with applicable ASTM, AASHTO. or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test resutts transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials FIELD DENSITY TESTING Client: Coppell Trade Center LP lrerracan Project Number:94051081 Report Number: 94051081.0028 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) 213 875' S from N end & 60' W of center line 1.5' BEG 1 6 15.0 109.6 93 214 875' S from N end & 90' E of center line 1.5' BEG I 6 14.7 110.4 94 215 875' S from N end & 90' W of center line 1.5' BEG 1 6 14.7 109.8 93 216 925' S from N end & 10' E of center line 1' BEG 1 6 13.6 112.0 95 217 925' S from N end & 60' W of center line 1' BEG 1 6 14.4 110.6 94 218 925' S from N end & 90' E of center line 1' BEG 2 6 18.3 103.4 94 219 925' S from N end &10' W of center line 1' BEG 2 6 18.6 102.8 94 220 925' S from N end & 60' E of center line 1' BEG 2 6 19.1 101.9 93 221 925' S from N end & 90' W of center line 1'BEG 2 6 19.0 102.4 93 222 975' S from N end at center line 1' BEG 3 6 17.8 101.0 95 223 975' S from N end & 50' E of center line 1' BEG 3 6 17.7 100.6 95 224 975' S from N end & 50' W of center line 1'BEG 3 6 19.1 100.8 95 225 990' S from N end & 60' E of center line .5' BEG 1 6 15.0 111.4 95 226 990' S from N end & 80' W of center line .5' BEG 1 6 14.8 109.4 93 227 990' S from N end & 90' E of center line .5' BEG 1 6 13.8 110.8 94 228 990' S from N end & 60' W of center line .5' BEG 1 6 14.7 111.5 95 229 990' S from N end & 80' W of center line .5' BEG 2 6 17.9 103.1 94 230 990' S from N end & 90' E of center line .5' BEG 2 6 18.1 104.3 95 231 990' S from N end & 10'W of center line .5' BEG 2 6 18.1 103.8 95 232 990' S from N end & 20' E of center line .5' BEG 2 6 17.6 104.1 95 233 990' S from N end & 10' W of center line .5' BEG 3 6 17.7 101.4 95 234 990' S from N end & 20' E of center line .5' BEG 2 6 19.1 103.2 94 Datum:BEG= below existing grade Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Technician: Michael E. edom (1) Ceppe~l Trade Center LP (1) Merriman Assoc Inc z/f J~/~. ~r~ ~ J'-~ (1) Pritchard Associates Inc (1) McFadden & Miller Reviewed by: ~' ~ M--/~,/~' (1) City of Coppell TX Robed D. Ray, S.E.T. (1) City of Coppell TX Senior Project Mana~/ , The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repeal is exclusively for the usez~e client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only-applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the proper[ies of other apparently similar or identical materials FIELD DENSITY TESTING Report Number: 94051081.0035 Service Date: April 9, 2005 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: April 18, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX **REVISED Description ~'~1 Light brown silty clay ~,/gravel Material Information Material Laboratory No. Test Method 1.510810005 ASTM D 698 2. 510810003 ASTM D 698 3. 510810002 ASTM D 698 4.510810008 ASTM D 698 Field Test Data Test No. Tan & brown clayey sand Dark reddish brown sandy clay Tan clayey sand Lift/ Mat. Test Location Elevation No. Number: 94051081 Lab Te<J~ Data ·' Optimum Max. Lab Water Dry Unit Content Weight ~tion (%) (pcf) 15.4 109.8 12.2 117.0 15.2 106.2 11.5 117.5 Probe Water Depth Content (inches) ~ __ 6 17.7 Building C 359 Test Pit #1, see attached sketch 4' BEG 3 360 Test Pit #1, see attached sketch 3' BEG 3 361 Test Pit #1, see attached sketch 2' BEG 2 362 Test Pit #1, see attached sketch 1' BEG 2 363 Test Pit #2, see attached sketch 4' BEG 1 364 Test Pit #2, see attached sketch 3' BEG 1 365 Test Pit #2, see attached sketch 2' BEG 2 366 Test Pit #2, see attached sketch 1' BEG 2 367 Test Pit #3, see attached sketch 4' BEG 1 368 Test Pit #3, see attached sketch 3' BEG 1 369 Test Pit #3, see attached sketch 2' BEG 2 370 Test Pit #3, see attached sketch 1' BEG 2 371 Test Pit ¢t4, see attached sketch 4' BEG .'4-"\ 372 Test Pit ¢t4, see attached sketch 3' BEG ,~ ~'~ ~ 373 Test Pit #4, see attached sketch 2' BECk/ ~/ 6 15.9 6 19.4 6 18.8 6 15.4 6 14.9 6 17.5 6 17.9 6 14.3 6 14.7 6 14.8 6 14.7 6 13.6 Proiect Requirements Water Content Minimum Dry Range Unit Weight (%) (% compaction) >/= +2 93 >/= +2 93 >/= +2 93 >/= +2 93 Dry Unit Dry Unit Weight Weight (pot} (% compaction) 100.1 / 94 101.2 95 108.8 93 109.1 93 106.6 97 104.7 95 108.4 93 109.7 94 106.3 97 102.1 93 109.0 93 108.9 93 113.4 ,~ 97 108.9 '~ 109.4 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials · FIELD DENSITY TESTING Client:coppell Trade Center LP ll'erracan Project Number:94051081 Report Number: 94051081.0035 Field Test Data Test No. Test Location Probe Water Dry Unit Dry Unit Lift/ Mat. Depth Content Weight Weight Elevation No. (inches) (%) (pot) (% compaction) 374 Test 375 Test 376 Test 377 Test 378 Test 379 Test 380 Test 381 Test 382 Test 383 Test 384 Test 385 Test 386 Test 387 Test 388 Test 389 Test 390 Test 391 Test 392 Test 393 Test 394 Test 395 Test 396 Test 397 Test 398 Test 399 Test 400 Test 401 Test 402 Test 403 Test Pit ~N., see attached sketch Pit #5, see attached sketch Pit #5, see attached sketch Pit #5, see attached sketch Pit #5, see attached sketch Pit #6, see attached sketch Pit #6, see attached sketch Pit #6, see attached sketch Pit #6, see attached sketch Pit #7, see attached sketch Pit #7, see attached sketch Pit #7, see attached sketch Pit #7, see attached sketch Pit #8, see attached sketch Pit #8, see attached sketch Pit #8, see attached sketch Pit #8, see attached sketch Pit #9, see attached sketch Pit #9, see attached sketch Pit #9, see attached sketch Pit #9, see attached sketch Pit #10, see attached sketch Pit #10, see attached sketch Pit #10, see attached sketch Pit #10 ;ee attached sketch Pit #11 see attached sketch Pit #11 see attached sketch Pit #11 see attached sketch Pit #11 see attached sketch Pit #12 see attached sketch 1' BEG 3 6 18.1 102.0 96 4' BEG 1 6 18.2 103.7 94 3' BEG 1 6 18.7 104.1 95 2' BEG 1 6 19.2 107.1 98 1' BEG 1 6 18.2 106.1 97 4' BEG 1 6 17.9 106.4 97 3' BEG 1 6 17.8 105.1 96 2' BEG 1 6 18.7 107.0 97 1' BEG 1 6 18.4 104.9 96 4' BEG 3 6 19.4 100.8 95 3' BEG 3 6 18.4 101.0 95 2' BEG 3 6 20.0 99.4 94 1' BEG 3 6 18.7 101.7 96 4' BEG 1 6 19.4 102.3 93 3' BEG 2 6 15.0 111.2 95 2' BEG 4 6 14.7 112.5 96 1' BEG 4 6 15.1 111.4 95 4' BEG 4 6 14.8 113.0 96 3' BEG 4 6 14.6 114.5 97 2' BEG 4 6 13.7 115.1 98 1' BEG 2 6 14.9 109.8 94 4' BEG 2 6 14.8 113.8 97 3' BEG 2 6 15.3 115.1 98 2' BEG 2 6 14.6 114.5 98 1' BEG 2 6 14.8 112.6 96 4' BEG 2 6 14.5 111.2 95 3' BEG 2 6 14.7 111.7 95 2' BEG 2 6 14.5 112.1 96 1' BEG 2 6 14.5 111.0 95 4' BEG 2 6 15.7 110.7 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently sirnilar or identical materials. FIELD DENSITY TESTING client: coppell Trade Center LP 'lrerracon Project Number:94051081 Report Number: 94051081.0035 Field Test Data Test No. Test Location Probe Water Dry Unit Dry Unit Lift/ Mat. Depth Content Weight Weight Elevation No. (inches) (%) (pcf} (% compaction) 404 Test Pit #12, 405 Test Pit #12, 406 Test Pit #12, 407 Test Pit #13, 408 Test Pit #13, 409 Test Pit #13, 410 Test Pit #13, 411 Test Pit #14, 412 Test Pit #14 413 Test Pit #14 414 Test Pit #14 415 Test Pit #15 416 Test Pit #15 417 Test Pit #15 418 Test Pit #15 418 Test Pit #16 419 Test Pit #16 420 Test Pit #16 421 Test Pit #16 422 Test Pit #17 423 Test Pit #17 424 Test Pit #17 425 Test Pit #17 426 Test Pit #18 427 Test Pit #18 428 Test Pit #18 430 Datum: see attached sketch 3' BEG 2 6 14.7 113.0 97 see attached sketch 2' BEG 2 6 14.7 112.5 96 see attached sketch 1' BEG 2 6 14.8 113.7 97 see attached sketch 4' BEG 2 6 14.7 109.8 94 see attached sketch 3' BEG 2 6 15.1 111.1 95 see attached sketch 2' BEG 4 6 14.3 113.7 97 see attached sketch 1' BEG 4 6 13.7 114.4 97 see attached sketch 4' BEG 4 6 14.1 114.1 97 see attached sketch 3' BEG 4 6 14.4 115.1 98 see attached sketch 2' BEG 4 6 13.6 113.7 97 see attached sketch 1' BEG 2 6 15.4 110.7 95 see attached sketch 4' BEG 2 6 15.4 109.4 94 see attached sketch 3' BEG 2 6 15.3 109.9 94 see attached sketch 2' BEG 2 6 14.5 109.0 93 see attached sketch 1' BEG 2 6 14.4 111.1 95 see attached sketch 4' BEG 4 6 13.7 114.2 97 see attached sketch 3' BEG 4 6 14.1 112.9 96 see attached sketch 2' BEG 4 6 14.4 112.8 96 see attached sketch 1' BEG 4 6 14.2 112.9 96 see attached sketch 4' BEG 4 6 14.2 114.1 97 see attached sketch 3' BEG 4 6 13.7 113.1 96 see attached sketch 2' BEG 4 6 13.9 113.7 97 see attached sketch 1' BEG 4 6 13.9 112.1 95 see attached sketch 4' BEG 4 6 13.7 111.9 95 see attached sketch 3' BEG 2 6 15.4 110.1 94 see attached sketch 2' BEG 2 6 15.4 109.9 94 1' BEG 4 6 13.9 113.7 97 Test Pit #18 see attached sketch BEG = below existing grade Comments: Test results on this report meet project specification, The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repot[ is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samptes tested at the iocation(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. FIELD DENSITY TESTING client: Coppel] Trade Center LP ll'erracon Project Number:94051081 Report Number: 94051081.0035 Comments (cont'd): NOTE: **This report was REVISED on 04/18/05 by changing the Test Nos. from 358 through 429 to 359 through 430. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method~,STM D2922, ASTM D3017 Gauge ID: 32769 Technician: Michael E. Odom (1) Coppell Trade Center LP (1) Merriman Assoc Inc (1) Pritchard Associates Inc (1) McFadden & Miller Reviewed by: ,/' ~ ~ ~ '~ '.,-/./ (1) City of Coppell TX Robert D. Ray, S.E.T. (1) City of Coppell TX Senior Project Manager/,,.~ The tests were performed in general accordance with applicable ASTM, AASHTQ, or DOT test methods. This report is exclusively for the use of t~e client indicated above and shall not be reproduced except in full without the writlen consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. 'irerracon Consulting Engineers & Scientists 7001 '~ N?