Loading...
MA 03/04-LR041127Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS CLIENT: Pavement Services Corp, PROJECT: City of Coppell Street Repair Project Job #03-007, Coppell, TX LOCATION OF POUR SET 1: LOCATION OF POUR SET 2: JOB NO.: DATE: SUPPLIER: 02.1077 27 November 2004 Pavement Services Paving, northbound lane in front of 248 Simmons SAMPLE DATA: Truck No. Ticket No. Time Batched Time Sampled Concrete Temp. {ASTM C1064) Air Content (ASTM C231) Unit Weight {ASTM C138} Ambient Temp. SET 1 SET 2 MIX NO. Cement Flyash Sand Water Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day IASTM Cl 43) psi Strength 408 7 12/04/O4 409 28 12/25/04 410 28 12/25/04 84,6O0 299O 130,300 4610 139,700 4940 28-Day Average 4780 4000 NOTE: Cylinders and all information furnished by contractor. TECHNICIAN: DISTRIBUTION: Contractor (1) Pavement Services Corp. (1) City of Coppell 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351~6419 Fax (214) 351-5148