Loading...
Four Seasons 2R-LR050502CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94041388.0107 Service Date: April 21,2005 lrerracan 8901 Carpenter Frwy, Ste #100 DaJlas, Texas 75247 (214) 630-1010 Client: Hill & Wilkinson LTD Attn: Charles Hoagland 800 Klein Rd Ste 100 Piano TX 75074 Report Date: May 02, 2005 Project: BCE Specialties 989 West Sandy Lake Road Coppell, TX Project Number: 94041388 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 1:04 pm Supplier: Southern Star Truck No: 5013 Mix I.D. No.: 7752 Water Added Onsite Before Test: Water Added Onsite After Test: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,O F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Plant: 27 Ticket No: 777377 0 Gallons 0 Gallons Sample Information Sample Time: 2:20 pm Date Cast: April 21, 2005 Technician: Francisco Morillo Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: W Entrance at Royal Lane Placement Location: Paving Result Specification Test Method 6.50 5.0 ASTM C143 4.5 4-6 ASTM C231 82 ASTM Cl 064 80 ASTM C1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) I 1 6.00 28.27 04/28/2005 7 92,720 3,280 1 2 6.00 28.27 04/28/2005 7 89,520 3,170 Average 3,230 1 3 05/19/2005 28 1 4 05/19/2005 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Francisco Morillo Repe Distribution (1) Hill & Wilkinson LTD (1) City of Coppell TX (4) Haray UcCu,a~'aLU Arohit.cts [nc (1) BCE Specia~ti.s Reviewed by: ..~ (1) TMBP Consulting Engineers ~' Robert D Ray, S E T (1) City of Coppell TX . . -'.T~. Senior Project Ma~,a~r The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repot[ is exclusively for the us,~f the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are o~y applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1