Loading...
Coppell Trade-LR050509CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051081.0059 Service Date: April 28, 2005 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: May 09, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 2:45 pm Plant: 6 Supplier: LMC Truck No: 5015 Mix I.D. No.: 1701 Water Added Onsite Before Test: Water Added Onsite After Test: 0 Gallons Ticket No: 6249566 0 Gallons Sample Information Sample Time: 4:00 pm Date Cast:April 28, 2005 Technician: Michael E. edom Weather Conditions: Fair Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Line E Inlet, Sta. 0+30 Placement Location: 10' Inlets, Line E, Sra. 0+30; Line D, Sta. 0+30; Line B, Sra. 0+25 Field Test Data Test Result Specification Test Method Slump, inches: 4.00 5.0 ASTM C143 Air Content, %: 4.9 3-7 ASTM C231 Concrete Temperature,O F: 87 ASTM C1064 Ambient Temperature, o F: 94 ASTM C1064 Plastic Unit Weight, pcf: 143.2 ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 05/05/2005 7 83,710 2,960 1 2 6.00 28.27 05/05/2005 7 78,350 2,770 Average 2,870 1 3 05/26/2005 28 1 4 05/2612005 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Michael E. edom 1) Coppell Trade Center LP (1) Merriman Asso(; Inc ~ / _~. / ~ (1) Pritchard Associates Inc (1) McFadden & Miller Reviewed by: ~ ~ C,"--'r (1) c Iy of Coppe TX Robert u. Ray, Senior Preject ~a~er The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repeal is exclusively for the u~ of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051081.0062 Service Date: April 29, 2005 'l['erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: May 09, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: Supplier: LMC Truck No: 0 Ticket No: Mix I.D. No.: 1701 WaterAdded Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 3.75 Air Content, %: 4.7 Concrete Temperature,O F: 80 Ambient Temperature, o F: 75 Plastic Unit Weight, pcf: 146.0 Laboratory Test Data Sample Information Sampte Time: 2:20 pm Date Cast: April 29, 2005 Technician: Michael E. Odom Weather Conditions: Fair Accumulative Yards: 3.5 Placement Method: Direct Discharge Sample Locations: See Placement Location Placement Location: Two Head Walls, Sta. 0+00, Line B 27"; Sta. 0+00, Line A 24" Specification Test Method 4.0 ASTM C143 3-7 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 05/06/2005 7 110,890 3,920 1 2 6.00 28.27 05/0612005 7 110,120 3,890 Average 3,910 1 3 05/27/2005 28 1 4 05/27/2005 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Michael E. Odom (1) Coppell Trade Center LP (1) ~iman ~soc Inc (1) Pritchard Ass~iat~ Inc (1) ~Fadden & Miller Reviewed by: (1) Ci~ of Cop~l TX ~ Robe~ D. Ray, S.E.T. ~ (1) Ci~ of ~p~ll TX Senior Project Man~ The t~ts were ~dorm~ in general accordance ~th applicable ASTM, AASHTO, or DOT test methods. This repo~ is exclusively for the use~e client indicated a~ve and shall not be reproduced ~cept in full without the wri~en consent of our company. T~t resuEs transmiffed herein am only applicable to the a~ual ~mples tested at the location(s) referenc~ and are not necessarily indicative of the pmpedies of other apparently similar or identical materials.