Coppell Trade-LR050502FIELD DENSITY TESTING Report Number: 94051081.0038 Service Date: April 13, 2005 'l['erracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: May 02, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Material Laboratory Content Weight Range Unit Weight No. Test Method Description and Classification (%) (pcf) (%) (% compaction) 1. 510810001 ASTM D 698 Light brown & brown clay w/sand & gravel 19.8 101.6 -1/+3 95 2.510810005 ASTM D 698 Light brown silty clay w/gravel 15.4 109.8 -1/+3 95 3. 510810002 ASTM D 698 Dark reddish brown sandy clay 15.2 106.2 -1/+3 95 4. 510810003 ASTM D 698 Tan & brown clayey sand 12.2 117.0 -1/+3 95 .Field Test Data Probe Water Dry Unit Dry Unit Test LiftJ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) Site Grading, See attached sketch 470 50' S & 30' W of NW corner of Buitding B 504.5 3 6 17.2 103.4 97 471 50' S & 50' E of NW corner of Building B 503.0 2 6 18.4 104.4 95 472 50' S & 150' E of NW corner of Building B 502.0 2 6 17.4 106.4 97 473 50' S & 250' E of NW corner of Building B 502.0 2 6 18.3 105.9 96 474 150' S & 30' W of NW corner of Building 503.5 2 6 18.4 106.9 97 B 475 150' S & 50' E of NW corner of Building B 503.5 2 6 18.3 109.0 99 476 150' S & 150' E of NW corner of Building 503.0 2 6 17.7 106.7 97 B 477 150~ S & 250' E of NW corner of Building 502.0 2 6 18.4 107.7 98 B 478 250' S & 30' W of NW corner of Building 502.5 2 6 18.1 108.4 99 B 479 250' S & 50' E of NW corner of Building B 502.5 3 6 18.1 102.7 97 480 250' S & 150' E of NW corner of Building 503.5 3 6 17.9 101.9 96 B The tests were perlormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) re[erenced and are not necessarily indicative ol the properties of other apparently similar or identical materLals. Page 1 of 2 FIELD DENSITY TESTING Client: Coppell Trade Center LP H3C 'lrerracan Project Number:94051081 Report Number: 94051081.0038 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) 481 250' S & 250' E of NW corner of Building 503.5 3 6 16.9 101.7 96 B 482 350' S & 50~ E of NW corner of Building B 504.0 3 6 16.8 102.1 96 483 350' S & 150' E of NW comer of Building 504.0 3 6 14.9 102.7 97 484 10' S & 100' E of NW corner of Building B 503.0 2 6 14.7 106.9 97 485 110' S & 100' E of NW corner of Building 503.0 2 6 14.9 107.6 98 B 486 210' S & 100' E of NW corner of Building 504.0 2 6 18.1 107.0 97 B 487 310' S & 100' E of NW corner of Building 503.5 2 6 18.3 108.9 99 B 488 100' S & 10' W of NE corner of Building B 502.0 2 6 17.7 110.7 100+ 489 200~ S & 10' W of NE corner of Building B 503.0 3 6 18.0 100.7 95 490 300' S & 10' W of NE corner of Building B 503.5 3 6 17.5 101.6 96 491 100' S & 20' E of NW corner of Building B 504.0 3 6 16.4 100.4 95 492 200' S & 20' E of NW corner o1 Building B 504.5 2 6 14.6 104.6 95 493 300' S & 20' E of NW corner of Building B 504.5 2 6 16.9 105.2 96 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Technician: Michael E. Odom (1) Coppe[I Trade Center LP (1) MerrJman Assoc Inc (1) Pritchard Associates Inc (1) McFadden & Miller Reviewed by. (1) City of Coppell TX Robert D. Ray, (1) City o~ Coppell TX Se nior Project/y~age~, The tests were pedormed in general accordance with applicable ASTM, AASHTO, or DOT test methods This repod is exclusively fo,~e us~ of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted her~ are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.