Loading...
WA0101-LR050524Construction Materials Testing and Environmental Consulting Texas CM% Inc 10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957 Fax (214) 352-6972 www .texascmt.com MOISTURE DENSITY RELATIONSHIP REPORT Test Report Date: Client: Sample Date: Project: Identification: Test Procedure: May 24, 2005 City of Coppell May 19, 2005 Hwy. 121 Water Line Project No: 205-0137 Moisture Report No. 1 Test Results: Method .................................................. A Optimum Moisture Content .................................. 10.5 percent Maximum Density ......................................... 117.9 pounds per cubic foot Rammer Type ............................................. Automatic Material Description ....................................... Orange & Light Brown Silty Sand ......................................................... w/sandy clayey balls Material Origin ........................................... Stockpile ~ 121 & Coppell Rd. Moisture Preparation Procedure .............................. Air Dry Liquid Limit ............................................. N/P Plastic Limit ............................................. N/P Plasticity Index ........................................... N/P Percent Passing No. 200 U.S. Sieve ........................... 31 Technician: AT cc: Ms Suzan C. Taylor - City of Coppell Mr kar~ Davis -City of Coppell Mr. Luis Velasquez - Fox Contractors, Inc. Mr. Douglas K Showers - Birkhoff, Hendricks & conway, LLP