Coppell Trade-LR050527CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94051081.0057 Service Date: April 27, 2005 Client: Coppell Trade Center LP Attn: Al Sorrels 5055 Keller Springs Rd Ste 300 Addison TX 75001 ll'erracan 8901 Carpenter Frvh', Ste #100 Datlas, Texas 75247 (214) 630-1010 Report Date: May 27, 2005 Project: Coppell Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 2:50 pm Plant: 7 Supplier: LMC Truck No: 1045 Mix I.D. No.: 1701 Water Added Onsite Before Test: Water Added Onsite After Test: 0 Gallons Ticket No: 7152171 0 Gallons Sample Information sample Time: 3:25 pm Date Cast: April 27, 2005 Technician: Michael E. Odom Weather Conditions: Fair Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: 15' Inlet, Lateral C3, 0+42 Placement Location: Line E, D, F, C, Head Wails, 0+00 one 10' inlet Line F, 0+29; Lateral C3, 15' inlet 0+42 Field Test Data Test Result Specification Test Method Slump, inches: 3.00 5.0 ASTM C143 Air Content, %: ASTM C231 Concrete Temperature,° F: 85 ASTM C1064 Ambient Temperature, o F: 85 ASTM C1064 Plastic Unit Weight, pcf: 148.4 ASTM Cl 38 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 05/04/2005 7 97,910 3,460 1 2 6.00 28.27 05/04/2005 7 102,790 3,630 Average 3,550 28.27 05/25/2005 28 132,620 ~' 4,690 1 3 6.00 1 4 6.00 28.27 05/25/2005 28 131,490 ~,650 Average -4,670 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Michael E. Odom (I) Coppell Trade Center LP (1) Merriman Assoc Inc (I) Pdtchard Associates Inc (1) M~Fadden & Miller Reviewed by: (1) Cityof Coppell TX ~' ~ Robert D. Ray,,, S.E~'"S.E . (1) City of Coppell TX Senior Project M~er The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. LABORATORY COMPACTION CHARACTERISTICS OF SOIL Report Number: 94051081.0065 Service Date: May 17, 2005 'll'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Clien~ter LP '"5'1:T55 Keller Springs Rd Ste 300 Addison TX 75001 Report Date: May 27, 2005 Project: Coppetl Trade Center NWC Sandy Lake & State St Coppell, TX Project Number: 94051081 Material Information Contractor: Metroplex Excavation Source of Material: Imported material Proposed Use: Flexible Base USCS: Sample Information Sampled By: Laramie S. Chronister Sample Location: Stockpile Sample Description: Crushed limestone flexible base Laboratory Test Data Test Procedure: Test Method: Sample Preparation: Rammer Type: ASTM D 698 Method C Moist Method Mechanical Maximum Dry Unit Weight, pcf: 124.8 Optimum Water Content, %: 8.4 Result Specifications Liquid Limit: NA Plastic Limit: NA Plasticity Index: NA % Passing #200: NA % Passing #40: NA Moisture Density Relations Zero Air Voids Curve for assumed specific gravity 2.70 Services- Moisture-Density Relations Report (1) Coppell Trade Center LP (1) Men'iman Assoc Inc (1) Pritchard Associates In¢ (1) McFadden & Miller Reviewed by:___ (1) city of Coppel~ TX Senior Project MaWr The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use'of the client" indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 REPORT OF REINFORCING STEEL OBSERVATION ' rerracon 8901 Carpenter Frv, y., Suite #100 DallaS, Texas 75247 Date of Service: Client No.: Client: 05/27/05 93345 Coppell Trade Center LP 5055 Keller Springs Rd Ste 300 Addison, TX 75001 RepOrt No.: 94051190.0011 Project No.: 94051190 ~.-----'-~ Project'~mde Center- Bldg_? f NWC Sandy Lake/Freeport Pkwy Coppell, TX Services: Drawings Utilized: Observe placement of reinforcing for compliance with furnished drawings. PROJECT DATA C-3, dated 03/17/05 Locations/Items Observed: Pavement: 0' to 250' S & 20' to 160' W of NW building comer Test Method: Visual Observation REPORT OF OBSERVATION Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bet Grade X Propedy ~od X Welded Splices Trash & Debris Re~n~ved X proper Bar Suppo~s X Lopped Splices X Number of Bars X P¢oper Cover/Clearance X Discrepancies/Comments: Any discrepancies found were corrected at the time of this observation unless otherwise Field Results Report To: Technician: B. Hatch Report Distribution: (1) Coppell Trade Center LP (1) TechniStructures (1) City of Coppell TX (1) City of Coppell TX 309acs (1) Merriman Assoc Inc 'll'erracan (1) Macatee Engineering Inc ' Robert D. Ray Senior Project ~r