TRANSMIT[AL
To: Charlene LaMattina From: Daniel Heischman, P,E.
Co: City of Coppell Date: May 11, 2005
Address: 255 Parkway Blvd CC: File
Coppell Texas 75019
Phone: 972-304-3681 Via: Courier
Re: Villas at Lake Vista Job #: 03067B
Coppell, Texas
Attached, please find the following:
3 Revised Sets of Construction Plans
Chadene,
The attached plans reflect the changes to the water/sewer plan as we have discussed. I have also made an
additional change per the direction of the home builder, I moved the irrigation meter that was along MacArthur
to the amenity center and removed the 1" meter/service that was originally there. The builder will serve the
landscaping and amenity center off the one 2" meter, Please recalculate the impact fees accordingly. Feel free
to contact me if you have any questions,
Thanks,
Daniel
Received by:
Date received:
Page 1 of 2
Charlene LaMattina
From:
To:
Date:
CC:
"Daniel Heischman" <DHeischman~daa-civil.com>
<clamattina~ci.coppell.tx.us>, <kmarvin@ci.coppell.tx.us>
5/4/2005 2:25 PM
"Mark Wakeland" <MarkW~WakelandProperties.com>, "Rodney Louviere" <rlouviere~daa-
civil.com>, <steveb@hwhomes.com>, <toates@ci.coppell.tx.us>
Charlene/Keith:
Per our conversations, the last remaining issue for approval to our construction
plans is the resolution for bringing water service to each individual town home unit
with sufficient pressure/flow for domestic use and fire protection. The builder
believes a 1" service/meter will be adequate for providing domestic and fire
protection to each unit. Steve Burke, with Hawkins-Welwood Homes, will provide Tim
Oates with the necessary calculations in the next couple of days.
The builder would also like to increase the size of the irrigation services/meters
to have them all at 2". In addition, we would like to move all water services and
sanitary sewer laterals to 1' off the property lines at we are proposing with the
front entry product. This is in order to prevent conflicts between water meters
with the sidewalks coming from the front door of the town homes to the street (as
shown on detail faxed to you). The changes will be reflected on the two sheets of
the Water and Sanitary Sewer Plan within our construction plans.
Please provide us with the revised impact fee calculations per the above mentioned
changes. Upon the Engineering Department's and Tim Oates' approval, we will pay the
associated fees and proceed to set up a preconstruction meeting wi.th the City.
Please contact me if you have any questions and/or if any the above is unclear or
incorrect.
Sincerely,
Daniel Heischman, P.E.
Dowdey, Anderson & Associates, Inc.
(972)931-0694
P.S. The following is the revised water meter schedule that will be reflected on
the construction plans:
Water Meter Schedule
Type Size No.
Dom/Fire 1" 94
Irrigation 2" 5
file://C :~Documents%20and%20Settings\clamattina\Local%20Settings\Temp\GW} 00001 .... 5/12/2005
Page 2 of 2
The (94) 1" meters are for the 93 units in phase one and the amenity center.
However, 95 services will be installed due to the extended pavement into phase two.