Coppell Trade-LR050603CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94051190.0010
Service Date: May 26, 2005
Client: Co~r LP
5055 Keller Springs Rd Ste 300
Addison TX;75001
lrerracan
8901 Carpenter Frwy, Ste #I00
Dallas, Texas 75247
(214) 630-1010
Report Date: June 03, 2005
Project: Coppell Trade Center - Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project Number: 94051190
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 1:29pm
Supplier: TXI
Truck No: 510
Mix I.D. No.: 9506
Plant: 141
Ticket No: 53080
Sample Information
Sample Time: 2:50pm Date Cast: May 26, 2005
Technician: Francisco Morillo
Weather Conditions: Clear
Accumulative Yards: 10
Placement Method: Direct Discharge
Sample Locations: See Placement Location
Placement Location: Column Footings, B, C, D, E/23, B, C, D,
E/24
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Result
4.75
82
86
Set Specimen Diameter Area
No. ID (inches) (sq. inches)
1 I 6.00 28.27
Specification
4-6
Test Method
ASTM C143
ASTM C231
ASTM Cl 064
ASTM C1064
ASTM C138
Date
Tested
06/02/2005
Age at Maximum Compressive
Test Load Strength
(days) (lbs) ¢ (psi)
7 88,230 ~
1 2
I 3
06/23/2005 28
06/23/2005 28
4
HoLd
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
Page 1 of 2
'lrerracan
CONCRETE COMPRESSIVE STRENGTH TEST
Client: Coppell Trade Center LP Project Number:94051190
Repor~ Number: 94051190.0010
Comments (cont'd):
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Francisco Morillo
Report Distribution:
(1) Coppell Trade Center LP
(1) TechniStructures
(1) City of Coppell TX
(1) City of Coppell TX
(1) McFadden & Miller Reviewed by:
(1) Macatee Engineering Inc Robert D. Ray,~,,,,[~
Senior P roje,,cY,~anager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.