ST9302-LR001204ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
Concrete Compression Test
Report
Tested For:
Fax Number:
CITY OF COPPELL
ATrN: KEN GRIFFIN
255 PARIG~VAY BLVD.
COPPELL, TX 75019
(972) 304-3570
Project Desc: SANDY LAKE ROAD PROJ NO. ST 93
COPPELL, TEXAS
I~eue Date: 12/04/2000
Placement Locetlon:
Date Placed:
Time Placed:
Slump (ASTM C-143):
Air Content:
Air Temperature:
Specimen Temperature:
Date Received:
Delivery Method:
RELD DA TA
PAVING, STATION 74+54 ON SANDY LAKE RD.
11/30/00
9:00 AM
2
5.25 (ASTM C-173)
65
70
12/1/00
PICKED UP BY ALPHA
Field Data Submitted By: HENSHAW, EKENG A
Mix Data Submitted By: ED BELL
Plant Number: -5.5 SK
Delivery Ticket No.: N/A
Made By: ALPHA
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESUL TS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Len~;h W;~[;, D;a~-_-.'.er Sq. In. Lo-_-~: PSI:
215 LAB 12/4/00 4 12 N/A 6 28.27 77541 2750
216 LAB 12/7/00 7 12 N/A 6 28.27 0
217 LAB 12/28/00 28 12 N/A 6 28.27 0
218 LAB HOLD HOLD 12 N/A 6 28.27 0
I Speclflcetions: 28
~_.~c,.~_ to Date: 3000
N/A
Notes: