Loading...
ST9302-LR001203ALPHA TESTING, INC. 2209 wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: CITY OF COPPELL ATTN: KEN GRIFFIN 255 PARK'~VAY BLVD. COPPELL, TX 75019 Fax Number: (972) 304-3570 Project Desc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS Our Repor~ No.: 98881-169 Issue Date: 12/03/2000 FIELD DA TA Placement Location: Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Delivery Method: Field Data Submlttsd By: Mix Data Submitted By: PAVING, SANDY LAKE RD. (EAST BOUND) Q STATION 13+50 11/28/00 9:15 AM 3.5 4 (ASTM C-173) 58 73 11/29/00 PICKED UP BY ALPHA SANDERS, JUSTIN S. BELL Plant Number: ON SITE Delivery Ticket No.: N/A Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Daya): Length Width Diameter Sq. In. Load: PSI: 202 LAB 12/2/00 4 12 N/A 6 28.27 94685 3340 203 LAB 12/5100 7 12 N/A 6 28.27 0 204 LAB 12/26/00 28 12 N/A 6 28.27 0 205 LAB 12/26/00 28 12 N/A 6 28.27 0 206 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 Results to Date: Notes: ' I "1"[i T I I ~ I