ST9302-LR001203ALPHA TESTING, INC.
2209 wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
Concrete Compression Test
Report
Tested For: CITY OF COPPELL
ATTN: KEN GRIFFIN
255 PARK'~VAY BLVD.
COPPELL, TX 75019
Fax Number: (972) 304-3570
Project Desc: SANDY LAKE ROAD PROJ NO. ST 93
COPPELL, TEXAS
Our Repor~ No.: 98881-169
Issue Date: 12/03/2000
FIELD DA TA
Placement Location:
Date Placed:
Time Placed:
Slump (ASTM C-143):
Air Content:
Air Temperature:
Specimen Temperature:
Date Received:
Delivery Method:
Field Data Submlttsd By:
Mix Data Submitted By:
PAVING, SANDY LAKE RD. (EAST BOUND) Q STATION 13+50
11/28/00
9:15 AM
3.5
4 (ASTM C-173)
58
73
11/29/00
PICKED UP BY ALPHA
SANDERS, JUSTIN S.
BELL
Plant Number: ON SITE
Delivery Ticket No.: N/A
Made By: ALPHA
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Daya): Length Width Diameter Sq. In. Load: PSI:
202 LAB 12/2/00 4 12 N/A 6 28.27 94685 3340
203 LAB 12/5100 7 12 N/A 6 28.27 0
204 LAB 12/26/00 28 12 N/A 6 28.27 0
205 LAB 12/26/00 28 12 N/A 6 28.27 0
206 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28
Results to Date:
Notes: