Coppell Trade-LR050608CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94051190.0018
Service Date: May 31, 2005
Client: Coppell Trade Center LP
Attn: Al Sorrels
5055 Keller Springs Rd Ste 300
Addison TX 75001
1Ferracun
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: June 08, 2005
Project: Coppell Trade Center - Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppeli, TX
Project Number: 94051190
Material Information
Specified Strength: 4500 psi ~ 28 Days
Batch Time: 3:40pm
Supplier: Southern Star
Truck No: 931
Mix I.D. No.: 9361
Water Added Onsite Before Test:
Water Added Onsite After Test:
Field Test Data
Test
Plant: 27
Ticket No: 833785
0 Gallons
0 Gallons
Result
Slump, inches: 3.25
Air Content, %: N/A
Concrete Temperature? F: 89
Ambient Temperature, o F: 84
Plastic Unit Weight, pcf: N/A
Laboratorv Test Data
Sample Information
Sample Time: 4:10pm Date Cast: May 31, 2005
Technician: Eric G. Jernigan
Weather Conditions: Partly sunny, warm & mild
Accumulative Yards: 9
Placement Method: Direct Discharge
Sample Locations: Back Wall
Placement Location: Back Wall of Culvert, 2nd from W
Specification
3-5
N/A
Te~ Method
ASTM C143
ASTM C231
ASTM C1064
ASTM C1064
ASTM C 138
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
1 1 6.00 28.27 06/07/2005 7 166,540 5,890
1 2 6.00 28.27 06/07/2005 7 161,930 5,730
Average 5,810
1 3 06/28/2005 28
1 4 06/28/2005 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Edc G. Jernigan
Report Distribution:
(1) Coppell Trade Center LP
(1) TechniStructures
(1) City of Coppell TX
(1) City of Coppel~ TX
(1) Merdman Assoc Inc
(1) McFadden & Miller
(1) Macatee Engineering Inc
Reviewed by: ~ ~
' sRe~;rr tp rD;j eR;Yi~
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the wdtten consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page I of I