ST9302-LR000630ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas. Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR CITY OF COPPELL DATE 06/30/00
COPPELL, TEXAS
PROJECT SANDY LAKE ROAD OUR REPORT NO. 98881-150
PROJECT NO. ST 93-02
COPPELL, TEXAS
TEST DATA:
I
TEST SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATE NUMBER MOIb-TURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
% PCF % PCF
473 06/30/00 FG 9L 18.1 107.3 18.7 108 100 3-A
TEST LOCATION:
473 15' NORTH AND 30' WEST FROM SOUTHEAST CORNER OF UPS DRIVE WAY
CC: NONE
1. FILL
2. NATURAL SUBGRADE
3, LIME STABILIZED
4. CEMENT TREATED
* A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~~C.
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D, RETEST
Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting /
7' r" '7 1T ' !