Loading...
MA0405-LR050616lone Engineenng 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: City of CoppelI Ms. Suzan Taylor, Engineering Dept PO Box 9478 CoppeI1 TX 75019 Project: Brick Paver Replacement MA 04-05 Report No.: 235390 Project No.: 0510346 Date of Service: 06/08/2005 Report Date: 06/16/2005 Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Pavement Services CONCRETE SUPPLIER: Redi-Mix PLP~qT: ] SPECIFICATION REQUmEMENTS 3600 psi ~ 28 Days 4" maximum NA ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C- 1064 ASTM C-1231 ASTM C-39 MIX DESIGN I.D.: 73 l PLACEMENT DATE: 06/08/2005 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 9:40am BATCH TIME: NA TEMPERATURE (F)- AIR 86 F CONCRETE: 89 F TRUCK NO: 230 TICKET NO: 148229 AIR CONTENT (%): NA UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Approach into Fire Station #2 at Condor and MacArthur SAMPLE LOCATION: Same as above REPORT OF TESTS MEASURED SLUMP (inches) 2.25 Concrete Compressive Cylinder 6" x 12" CYLLNDER MAXIMUM MARKED DATE AGE DIAMETER AREA LOAD SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) COMPRESSIVE STRENGTH (psi) FRACTURE TYPE 1 I 06/15/2005 7 6.00 28.26 I 2 07/06/2005 28 0.00 0.00 1 3 07/06/2005 28 0.00 0.00 I 4 Hold Water added at site: Technician: Doyle Mackey Report Distribution: (!) CiD' of Coppell (I) City of Coppell 4 gallons Started: 8:45am Finished: ]0:30am 107970 3820 Unbonded Cap Unbonded Cap Unbonded Cap .one C°fay Stark Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibiliW for variation in quality (composition. appearance, etc) or any other feature of similar subject maaer provided by persons or conditions over which we have no control Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd ~ISS Page 1 ofl :- .one Engineenng 8908 Ambassador Row. Dallas. TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 IN-PLACE DENSITY TESTING Client: City of Coppell Ms. Suzan Taylor, Engineering Dept PO Box 9478 Coppell TX 75019 Project: Brick Paver Replacement MA 04-05 Report No.: 235497 Project No,: 0510346 Date of Service: 06/09/2005 Report Date: 06/16/2005 Services: Perform In-Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Pavement Services Test Methods: ASTM D-2922 ASTM D-3017 Standard Counts Gauge: Troxler 3430 Moisture Density Gauge Serial No: 32719 Current: 635 Current: 2792 Test Mode: DT Previous: 635 Prexfous: 2783 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density Recycled crushed concrete w/Clayey Sand 12.5 117.0 -2/+2 95 min FIELD DENSITY TESTS TEST PROBE NO TEST LOCATION DEPTH M/D MOISTURE WET DENSITY DRY DENSITY DENSITY No. (%) (pcf} (pet") (% max) Flex base subgrade 1 Village Drive approach, 25' south of 8" 1 14.3 131.1 114.7 98 centerline, northbound side Flex base subgrade 2 Village Drive, approach, 20' north of 8" 1 14.5 I30.6 1 I4.1 98 centerline, northbound side Technician: Bobby Robinson Report Distribution: (1) City of Coppell ( 1 ) CiD, of Coppell Test results on this report meet project specification. Started: 8:45am Finished: 10:00a Ron~~g Clay Stark Project Manager LIMITATIONS; The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibdi~y for variation in quality (composition. appearance, ere ) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in fall without the writren approval of Roue Engineering Services, Ltd. 07TM Page 1 of I