Ballet TX-LR050622SAM ENGINEERING & TESTING, L.P.
'I~ Serving The Geo-lndustry Since 1974 ,~
1115 Luke Street, Suite 100
Irving, Texas 75061
Phone: (972) 790-1910 · FAX: (972) 790-0967
IN-PLACE DENSITY OF SOIL
CLIENT: Head Construction, Inc. REPORT DATE: 6/22/05 TEST DATE: 6/21/05
3030 LB J, Suite 700
Dallas, TX 75234 TEST METHOD:ASTMD-2292 & 3017
PROJECT: Propo~s *ASTM D698A - See Proctor Report for Details
,~s Court
Coppell, TX Minimum Required Compaction = 95%
PROJECT#: 285TXIK5 REPORT#: 14 PAGE 1 OF 1
ATTN: Ken Head SE&T TECHNICIAN: Mark Brumle¥
TEST AREA FIELD RESULTS ~ LAB RESULTS *
No~hwest Corner Final 1 114 13 4 117 13 10-16 97 P
Southeast Corner Final 1 116 14 4 117 13 10-16 99 P
Middle Final 1 113 14 4 117 13 10-16 96 P
No~heast Corner Final 1 115 13 4 117 13 10-16 98 P
Southwest Corner Final 1 115 13 4 117 13 10-16 98 P
Fire Lane - No~hwest Corner Final .5 113 12 2 117 12 9-15 96 P
Fire Lane - No~h Middle Final .5 115 13 2 117 12 9-15 98/ P
All densities meet the minimum required values
project and we trust that this report is satisfactory.
Very Truly Yours,
SAM Engineering & Testing, L.P
Sadik (SAM) AI-Musawe, M.Sc., Ph.D.,
Civil & Environmental Engineer
Texas Registration Number: 61893
been a pleasure to serve you on this