Loading...
Stringfellow 1R-CS050526DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS fTEM: PD-203R-R~ Nationwide Insurance, zoning change request from PD-203-R (Planned Development-203-Retail) to PD-203R-R (Planned Development-203 Revised-Retail) to allow the construction of a 3,028-square-foot office building on 0.42 of an acre of property located at the southwest corner of Sandy Lake and Moore Roads, at the request of Bob Anderson. STAFF REP.: Matt Steer PROJECT ID# PD-05-0025 DRCDATE: May 26, 2005 and June 2, 2005 CONTACT: Kenneth M. Gri~n, P.E., Dir. o[ En~ineerin~/Public Works 972/304-3686 COMMENT STATUS: ,/PRELIMINARY ~nrA · o~7~e vn Detail Site Plan 1. Show the band of stamped concrete at the entry along Sandy Lake Road. 2. Remove "See Civil" from the 6' High Masonry Wall call-out. The Civil drawings contain an outdated detail that is no longer a City of Coppell standard. Additionally, the Brick Screening Wall detail calls out "Wall design per City of Coppell Standards." Remove this call-out. The wall should be designed and sealed by a licensed P.E. and submitted to Building Inspections for review. Landscape Plan 3. Move trees out of utility and drainage easements along the western side of the property. DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Stringfellow Addition, Lot II Block Al Replat~ (Nationwide Insurance), being a rcplat of Tract 1, Block A, to allow the construction of a 3,028-square-foot office building on 0.42 of an acre of property located at the southwest comer of Sandy Lake and Moore Roads, at the request of JDJR Engineers. STAFF REP.: Matt Steer PROJECT ID# RP-05-0026 DRCDATE: May 26, 2005 and June 2, 2005 CONTACT: Kenneth M. Gri~n, P.E., Dir. o~ En~ineerin~/Public Works 972/304-3686 COMMENT STATUS: ~PRELIMINARY ~'TER P~Z Cover Sheet 1. The engineer's seal should appear on the cover. Plat 2. The "5'x5' Water Easement" should be increased to a 25'x25' Water Easement. 3. Provide a 25'x25' utility or water easement for the location of the domestic and irrigation meters. (See comment 1 under Utility Services Plan.) Site Dimensional Control Plan 4. Accessibility Notes should also comply with ADA standards, on this and all sheets. 5. Traffic Control Details should comply with TxMUTCD; lane closures may only take place between 9:00 a.m. and 4:00 p.m. Grading and Paving Plan 6. The surface drainage from drainage areas BI and C2 should not sheet flow to the street. Pick up this flow and convey it on site to the storm drain system. 7. How will the northward-flowing off-site drainage from the portion of drainage area A1 that lies north of the proposed inlet reach the proposed inlet? How will the off-site drainage reach either of the inlets through the proposed masonry wall? / Utility Services Plan 8. The proposed domestic and irrigation water meters should be located on private property within a 25'x25' utility or water easement, not in the public utility easement. 9. Provide a clean out where the private sanitary sewer meets the public sanitary sewer (outside the limits of the existing sidewalk). 10. Replace the 12" x6" taping sleeve with a 16" x6" tapping sleeve tb ,'tap the existing 16" water line. Standard Construction Details 11. Remove City of Coppell Standard Details from the Civil set. The contractor will be required to have a full set of the most current details on the job site at all times. (New standard details were adopted in May, 2005.)