Coppell Trade-LR050617FIELD DENSITY TESTING
Report Number: 94051190.0013
Service Date: May 26, 2005
Client: Coppell Trade Center LP
Attn: Al Sorrels
5055 Keller Springs Rd Ste 300
Addison TX 75001
lrerracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: June 17, 2005
Project: Coppell Trade Center - BIdg C
NWC Sandy Lake/Freeport Pkwy
Coppeli, TX
Project Number: 94051190
Material Information Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pct~ (%) (% compaction)
1. 510810002 ASTM D 698 Dark reddish brown sandy clay 15.2 106.2 >/= +4 95
2. 510810006 ASTM D 698 Dark brown clay 28.6 84.6 >/= +4 95
Field Test Data Probe Water Dry Unit Dry Unit
Test LiftJ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pc~) (% compaction)
Spread Rootings
48 19/C 5' BFG 1 6 19.4 101.9 96
49 19/D 5.3' BFG 2 6 23.6 * 90.5 100+
50 19/E 5.3 BFG 1 6 14.0 * 108.5 100+
51 18/C 5.3 BFG 1 6 13.4 * 109.0 100+
52 18/D 5.1 BFG 1 6 19.6 102.3 96
53 17/D 5.2 BFG 1 6 12.8 * 108.8 100+
Datum: BFG = below final grade
Comments:
An asterisk (*) appears next to test results which do NOT meet the project specifications.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method~,STM D2922, ASTM D3017
Technician: Francisco Morillo
Field Results Reported To: Superintendent
Report Distribution:
(1) Coppe~l Trade Center LP
(1) TechniStructures
(1) City of Coppell TX
(1) City of Coppell TX
(1) Merriman Assoc Inc
(1) McFadden & Miller
(t) Macatee Engineering Inc
Robert D. Ray, S.E.~
Senior Project Ma~er
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
rnaterials.
Page 1 of 1
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94051190.0029
Service Date: June 9, 2005
Client: Coppell Trade Center LP
Attn: Al Sorrels
5055 Keller Spdngs Rd Ste 300
Addison TX 75001
lrerracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: June 17, 2005
Project: Coppell Trade Center - Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project Number: 94051190
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 6:25am Plant: 141
Supplier: TXI
Truck No: 37
Mix I.D. No.: 8206
Water Added Onsite Before Test: 10 Gallons
Field Test Data
Test
Result
Slump, inches: 5.00
Air Content, %: 4.0
Concrete Temperature,O F: 92
Ambient Temperature, o F: 75
Plastic Unit Weight, pcf: 144.8
Laboratory Test Data
Set Specimen Diameter Area
No. ID (inches) (sq. inches)
Ticket No: 59569
Sample Information
sample Time: 7:20am Date Cast: June 9, 2005
Technician: Burl E. Thomas
Weather Conditions: Clear
Accumulative Yards: 60
Placement Method:
Sample Locations: 60' N & 20' W of property comer
Placement Location: Paving
Specification
3-5
4-6
1 1 6.00 28.27 06/16/2005 7
1 2 07/07/2005 28
1 3 07/07~2005 28
Test Method
ASTM C143
ASTM C231
ASTM C1064
ASTM C1064
ASTM C138
Age at Maximum Compressive
Date Test Load Strength
Tested (days) (lbs) (psi)
111,070 3,930
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transrn[tted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94051190.0029
Service Date: June 9, 2005
Client: Coppell Trade Center LP
Attn: Al Sorrels
5055 Keller Springs Rd Ste 300
Addison TX 75001
l['erracon
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: June 17, 2005
Project: Coppell Trade Center- Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project Number: 94051190
Material Information
Specified Strength: 3000 psi @ 28 Days
Sample Information
Sample Time: 8:12am Date Cast: June 9, 2005
Technician: Bud E. Thomas
Batch Time: 7:32am Plant: 141 Weather Conditions: Clear
Supplier: TXI Accumulative Yards: 140
Truck No: 66 Ticket No: 59454 Placement Method: Direct Discharge
Mix I.D. No.: 8206 Sample Locations: 58' N & 108' W of SE corner
Water Added Onsite Before Test: 10 Gallons Placement Location: Paving
Water Added Onsite After Test: 0 Gallons
Field Test Data
Test Result' Specification Test Method
Slump, inches: 6.0 3-5 ASTM C143
Air Content, %: 4.2 4-6 ASTM C231
Concrete Temperature,° F: 93 ASTM C1064
Ambient Temperature, o F: 80 ASTM C1064
Plastic Unit Weight, pcf: ASTM C138
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
2 1 6.00 28.27 06/16/2005 7 110,400
2 2 07/07/2005 28
2 3 07/07/2005 28
3,900
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94051190.0029
Service Date: June 9, 2005
'll'erracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Coppell Trade Center LP
Attn: Al Sorrels
5055 Keller Springs Rd Ste 300
Addison TX 75001
Report Date: June 17, 2005
Project: Coppell Trade Center - Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project Number: 94051190
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 8:44am Plant: 141
Supplier: TXI
Truck No: 110 Ticket No: 59694
Mix I.D. No.: 8206
WaterAdded Onsite Before Test: 10 Gallons
Field Test Data
Test
Result
Slump, inches: 6.25
Air Content, %: 4.6
Concrete Temperature,° F: 93
Ambient Temperature, o F: 81
Plastic Unit Weight, pcf: 144.0
Sample Information
Sample Time: 9:44am Date Cast: June 9, 2005
Technician: Burl E. Thomas
Weather Conditions: Clear
Accumulative Yards: 230
Placement Method: Direct Discharge
Sample Locations: 33' N & 320' W of SE property corner
Placement Location: Paving
Specification
3-5
4-6
Test Method
ASTM C143
ASTM C231
ASTM C1064
ASTM C1064
ASTM C138
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (SCl. inches) Tested (days) (lbs) (psi)
3 1 6.00 28.27 06/16/2005 7 113,730
3 2 07/07/2005 28
3 3 07/07/2005 28
4,020
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein ara only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
CONCRETE COMPRESSIVE STRENGTH TEST
'Report Number: 94051190.0029
Service Date: June 9, 2005
Client: Coppell Trade Center LP
Attn: Al Sorrels
5055 Keller Springs Rd Ste 300
Addison TX 75001
lrerracan
8901 Carpenter Frw,/, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: June 17, 2005
Project: Coppell Trade Center- BIdg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project Number: 94051190
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 10:25am Plant: 141
Supplier: TXI
Truck No: 111
Mix I.D. No.: 8206
Water Added Onsite Before Test: 10 Gallons
Water Added Onsite After Test: 0 Gallons
Field Test Data
Test Result-
Slump, inches: 4.50
Air Content, %: 4.0
Concrete Temperature,o F: 95
Ambient Temperature, o F: 87
Plastic Unit Weight, pcf:
Laboratory Test Data
Set Specimen Diameter Area
No. ID (inches) (sq. inches)
Ticket No: 59876
Sample Information
Sample Time: 11:35am Date Cast: June 9, 2005
Technician: Burl E. Thomas
Weather Conditions: Clear
Accumulative Yards: 340
Placement Method: Direct Discharge
Sample Locations: 35' N & 280' E of SE property corner
Placement Location: Paving
Specification
3-5
4-6
Date
Tested
4 1 6.00 28.27 06/16/2005
4 2 07/07/2005
4 3 07/07/2005
Test Method
ASTM C143
ASTM C231
ASTM C1064
ASTM C1064
ASTM C138
Age at Maximum Compressive
Test Load Strength
(days) (lbs) (psi)
7 112,320 3,970
28
28
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Bud E. Thomas
Report Distribution:
(1) Coppell Trade Center LP
(1) TechniStructures
(1) City of Coppell TX
(1) City of Coppell TX
(1) Merriman Assoc Inc
(1) McFadden & Miller
(1) Macatee Engineering Inc
Reviewed by ~
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the wdtten consent of our company. Test results transmuted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.