Coppell Trade-LR050615FIELD DENSITY TESTING
Report Number: 94051190.0008
Service Date: May 24, 2005
Client: Coppell Trade Center LP
Attn: Al Sorrels
5055 Keller Springs Rd Ste 300
Addison TX 75001
1E rracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: June 15, 2005
Project: Coppell Trade Center - Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project Number: 94051190
Material Information Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pcf) (%) (% compaction}
1. 510810065 ASTM D 698 Crushed limestone flexible base 8.4 124.8 -2/+2 95
Field Test Data Probe Water Dry Unit Dry Unit
Test LiftJ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pcf) (% compaction)
Spread Footings
27 A/24 4' BFG 1 6 10.2 120.5 97
28 B/24 4' BFG 1 6 10.1 120.6 97
29 C/24 4' BFG 1 6 9.8 121.3 97
30 D/24 4' BFG 1 6 10.0 119.0 95
31 B/24 3' BFG 1 6 10.3 119.0 95
32 C/24 3' BFG 1 6 10.2 120.7 97
33 D/24 3' BFG 1 6 9.7 122.4 98
34 E/24 3' BFG 1 6 9.2 121.8 98
35 B/23 4' BFG 1 6 10.0 119.6 96
36 C/23 4' BFG 1 6 8.9 123.1 99
37 D/23 4' BFG 1 6 9.4 121.9 98
38 E/23 4' BFG 1 6 8.6 123.0 99
39 B/22 4' BFG 1 6 8.5 124.3 100
40 C/22 4' BFG 1 6 9.7 122.6 98
41 D/22 4' BFG 1 6 10.1 120.8 97
42 E/22 4' BFG 1 6 9.6 121.8 98
43 B/21 4' BFG 1 6 9,1 122,7 98
44 C/21 4' BFG 1 6 8.0 122.4 98
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the wdtten consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 2
.FIELD DENSITY TESTING
Client:Coppell Trade Center LP
lrerracon
Project Number:94051190
Report Number: 94051190.0008
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pct') (% compaction)
45 D/21 4' BFG 1 § 8.5 123.7 99
46 E/21 4' BFG 1 6 7.8 121.9 98
47 B/20 4' BFG 1 6 8.8 122.0 98
Datum: BFG = below final grade
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID: 2207
Technician: Laramie S. Chronister
Field Results Reported To: Ted
Re port Di st ri bution: ~e'~~,,~y
(1) Coppell Trade Center LP (1) Merriman Assoc Inc
(1) TechniStructures (1) McFadden & Mifler Reviewed by:
(1) City of Coppell TX (1) Macatee Engineering Inc Robert D. Ray, ~
(1) City of Coppell TX
Senior Project M~nager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the usa of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 2 of 2
FIELD DENSITY TESTING
'Report Number: 94051190.0005
Service Date: May 23, 2005
Client: Coppell Trade Center LP
~A I ~s.. ;'r "'
5055 Keller Springs Rd Ste 300
Addison TX 75001
1Ferracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: June 15, 2005
Project: Coppell Trade Center- Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project Number: 94051190
Material Information Lab Test Data Project Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pcf) (%) (% compaction)
1. 510810002 ASTM D 898 Dark reddish brown sandy clay
15.2 106.2 >/= Opt. 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pC0 (%compaction)
Spread Footings 0~~
6 20lB 5' BFG 1 6 26.2 * 93.5
7 21/D ~ 5' BFG 1 6 16.4 106.4
8 Retest of#3, dated 05/20/05f ] 1 6 18.4 102.5 97
9 23/D ~ 5,4' BFG 1 6 18.2 101.7 96
10 24/D 5.3' BFG 1 6 17.7 104,2 98
11 24/E 5.8' BFG 1 6 16.9 103.3 97
12 23/E 5,3' BFG 1 6 17,5 101.6 96
13 22/E 5' BFG 1 6 18.4 101.9 96
14 21/E 5~2' BFG 1 6 17.1 103.0 97
15 20/E 5.4' BFG 1 6 16.3 103.8 98
16 20/D 5.1' BFG 1 6 18.3 101.9 96
17 20/C 5' BFG 1 6 19.0 101.1 95
18 21/C 5.2' BFG 1 6 17.1 102.2 96
19 22/C 5.5' BFG 1 6 17.7 102.5 97
20 23/C 5.7' BFG 1 6 16.5 104.3 98
21 24/C 5.6' BFG 1 6 18.1 101.6 96
22 Retest #1. dated 05/20/05 ~) 1 6 16.8 105.0 99
23 Retest #2. dated 05/20/05 t~~ 6 16.5 104,2 98
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
· FIELD DENSITY TESTING ' rr rfacon
Client:Coppell Trade Center LP
Project Number:94051190
Report Number: 94051190.0005
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pcf) (% compaction)
24 22/B 5.6' BFG 1 6 17.2 102.1 96
25 21/B 5.4' BFG 1 6 17.0 101.8 96
26 Retest ~6, dated 05/23/05 1 6 16.5 103.9 98
Datum: BFG = below final grade
Comments:
An asterisk (*) appears next to test results which do NOT meet the project specifications.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID: 2207
Technician: Laramie S. Chrenister
Field Results Reported To: Ted
Report Distribution:
(1) Coppell Trade Center LP
(1) TechniStructures
(1) City of Coppell TX
(1) City of Coppell TX
(1) Merriman Assoc [nc
(1) McFadden & Miller
(1) Macatee Engineering
Robert D. Ray,~.T.
Senior Proje~lanager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94051190.0024
Service Date: June 7, 2005
Client: Coppell Trade Center LP
Attn: Al Sorrels
5055 Keller Springs Rd Ste 300
Addison TX 75001
lrerracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: June 15, 2005
Project: Coppell Trade Center - Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project Number: 94051190
Material Information
Specified Strength: 4000 psi (~ 28 Days
Batch Time: 5:53am Plant: 41
Supplier: TXI
Truck No: 807
Mix I.D. No.: 8206
Water Added Onsite Before Test:
Water Added Onsite After Test: 0 Gallons
Field Test Data
Test
Result
Slump, inches: 5.75
Air Content, %: 10.2
Concrete Temperature,o F: 87
Ambient Temperature, o F: 78
Plastic Unit Weight, pcf: 136.0
Laboratoq/ Test Data
set Specimen Diameter Area
No. ID (inches) (sq. inches)
1 1 6.00 28.27
1 2 6.00 28.27
1 3
1 4
Ticket No: 57463
0 Gallons
Sample Information
sample Time: 6:35am Date Cast: June 7, 2005
Technician: Michael E. Odom
Weather Conditions: Partly cloudy
Accumulative Yards: 30
Placement Method: Direct Discharge
Sample Locations: 5' - 15' E of Curb Inlet ~
Placement Location: Bldg C, W side Fire Lane & Truck Dock,
Slab-on-Grade, See attached sketch
Specification
5 Max
3-6
Test Method
ASTM C143
ASTM C231
ASTM CI064
ASTM C1064
ASTM C138
Age at Maximum Compressive
Date Test Load Strenj:lth
Tested (days)(lbs)~PS..~/
06/14/2005 7 72,640 ( 2
06/14/2005 7 74,000 ~,. 2~;~3
Average 2,600
07/05/2005 28
07/05/2005 28
Comments:
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 4
CONCRETE COMPRESSIVE STRENGTH TEST
· Report Number: 94051190.0024
Service Date: June 7, 2005
Client: Coppell Trade Center LP
Attn: Al Sorrels
5055 Keller Spdngs Rd Ste 300
Addison TX 75001
'lrerracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: June 15, 2005
Project: Coppell Trade Center - Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
ProJect Number: 94051190
Material Information
Specified Strength: 4000 psi @ 28 Days
Batch Time: 7:19am Plant: 41
Supplier: TXI
Truck No: 71
Mix I.D. No.: 8206
Water Added Onsite Before Test:
Water Added Onsite After Test: 10 Gallons
Field Test Data
Test Result
Slump, inches: 5.50
Air Content, %: 8.7
Concrete Temperature,° F: 87
Ambient Temperature, o F: 852
Plastic Unit Weight, pcf: 136.0
Laborator~ Test Data
Ticket No: 57609
0 Gallons
Sample Information
sample Time: 7:55am Date Cast: June 7, 2005
Technician: Michael E. Odom
Weather Conditions: Cloudy
Accumulative Yards: 110
Placement Method: Direct Discharge
Sample Locations: 10' - 15' S & 30' E of Curb Inlet ~6
Placement Location: See page 1
Specification Test Method
5 Max
3-6
Set Specimen Diameter Area Date
No. ID (inches) (sq. inches) Tested
2 1 6.00 28.27 06/14/2005
2 2 6.00 28.27 06/14/2005
2 3 07/05/2005
2 4 07/05/2005
ASTM C143
ASTM C231
ASTM C1064
ASTM C1064
ASTM C138
Age at Maximum Compressive
Test ~
(days)
7 (~,990 3,360 j
7 N~610 3,27~
Averagc~'~0
28
28
Comments:
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT teat methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company, Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not eecessarily indicative of the properties of other apparently similar or identical
materials.
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94051190.0024
Service Date: June 7, 2005
Client: Coppell Trade Center LP
Attn: At Sorrels
5055 Keller Springs Rd Ste 300
Addison TX 75001
lrerracan
8901 Carpenter Fn~, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: June 15, 2005
Project: Coppell Trade Center- Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project Number: 94051190
Material Information
Specified Strength: 4000 psi @ 28 Days
Batch Time: 9:42am
Supplier: TXI
Truck No: 837
Mix I.D. No.: 8206
Water Added Onsite Before Test:
Water Added Onsite After Test:
Field Test Data
Test
Plant: 41
Ticket No: 57840
0 Gallons
0 Gallons
Result
Slump, inches: 5.25
Air Content, %: 5.3
Concrete Temperature,o F: 89
Ambient Temperature, o F: 87
Plastic Unit Weight, pcf: 143.2
Sample Information
Sample Time: 10:28am Date Cast: June 7, 2005
Technician: Michael E. Odom
Weather Conditions: Cloudy
Accumulative Yards: 220
Placement Method: Direct Discharge
Sample Locations: 40' & 60' E of Curb Inlet
Placement Location: See page 1
Specification Test Method
5 Max
3-6
ASTM C143
ASTM C231
ASTM CI064
ASTM C1064
ASTM C138
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
3 1 6.00 28.27 06/14/2005 7 84,~ 3,000 ~
3 2 6.00 28.27 06/14/2005 7
Average 3,070
3 3 07/05/2005 28
3 4 07/05/2005 28
Comments:
Services - Obtain samples of fresh concrete at the placement locations, pedorm required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
CONCRETE COMPRESSIVE STRENGTH TEST
· Report Number: 94051190.0024
Service Date: June 7, 2005
1Ferracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Coppell Trade Center LP
Attn: Al Sorrels
5055 Keller Springs Rd Ste 300
Addison TX 75001
Report Date: June 15, 2005
Project: Coppell Trade Center- Bldg C
NWC Sandy Lake/Freeport Pkwy
Coppell, TX
Project Number: 94051190
Material Information
Specified Strength: 4000 psi @ 28 Days
Batch Time: 11:55am
Supplier: TXI
Truck No: 837
Mix I.D. No.: 8206
WaterAdded Onsite Before Test: 15 Gallons
Water Added Onsite After Test: 5 Gallons
Field Test Data
Test Result
Slump, inches: 4.00
Air Content, %: 4.3
Concrete Temperature,O F: 92
Ambient Temperature, o F: 92
Plastic Unit Weight, pcf: 144.8
Laboratory Test Data
set Specimen Diameter Area
No. ID (inches) (sq. inches)
4 1 6.00 28.27
4 2 6.00 28.27
Plant: 41
Ticket No: 58031
Sample Information
Sample Time: 1:00pm Date Cast: June 7, 2005
Technician: Michael E. Odom
Weather Conditions: Cloudy
Accumulative Yards: 310
Placement Method: Direct Discharge
Sample Locations: 80' E of Curb Inlet ~
Placement Location: See page 1
Specification
5 Max
3-6
Test Method
ASTM C143
ASTM C231
ASTM C1064
ASTM C1064
ASTM C138
Age at Maximum Compressive
Date Test Load Strength
Tested (days) (lbs)
06/14/2005 7 114,920 4,060 ~j
06/14/2005 7 110,760 3,920~....~
~ ,.1,~90
4 3 07/05/2005 28
4 4 07/05/2005 28
Comments:
NOTE: Plant and superintendent were notified of air content test results.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Michael E. Odom
Report Distribution:
(1) Coppell Trade Center LP
(1) TechniStructures
(1) City of Coppell TX
(1) City of Coppell TX
(1) Merriman Assoc Inc
(1) McFadden & Miller
(1) Macatee Engineering Inc
Senior Pr(~ject ~
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.