Ballet TX-LR050628 E.G .EE. .G & TEST .G, L.P. 1~ Serving The Goo-Industry Since 1974 .~ 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 o FAX: (972) 790-0967 Materials Testing DRILLED PIER INSPECTION REPORT REPORT DATE: 6/29/05 Tf-~T DATE: 6/28/05 CLIENT: Head Construction, Inc. TEST METHOD: Visual 3030 LB J, Suite 700 Dallas, TX 75234 ~ CASING (YES/NO): YES* f CASING DEPTH (FT): PROJECT: Proposed Ball Texas WATER I DRY (FT): * 145 Fitnes~,~urt Copp~X PLUMB (YES I NO): YES ATTN: Ken Head SE&T TECHNICIAN: Dominic Gonzales PROJECT NO.: 286TXlK5 REPORT NO. PAGE t OF 3 10 30" 24" 24 19 Hard to yeP/hard gray SHALE 14 30" 24" 22.6 17 20 30" 24" 24.2 19 13 24" 18" 24 18 12 24" 18" 24.2 18 11 24" 18" 23.5 17.5 15 30" 24" 22.0 17.0 r Notes: * (1). The above pier numbers are per the attached sketch. (2). Water seepages were encountered in all piers. Therefore, steel casings with a 24" diameter/ 15'-16' deep, a 30" diameter/16'-20' deep and a 30" diameter/20' deep were used. (3). All above piers were satisfactory and in-accordance with the on-site foundation plan Steve Foose and dated 5118105. I I I _~'~,,{~,_..~__1- Reinforcing steel placed per plans & specifications unless otherwise noted. It has been a pleasure to serve you on this project & we trust that this Very Truly Yours, SAM Engineering & Testing, Inc. Sadik (SAM)AI-Musawe, MSc., Ph.D., P.E. Civil & Environmental Engineer Texas Registration Number: 61893 satisfactory. G:120051286txik51DpirlDpir17ILL SAM ENGINEERING & TESTI.G, Serving The Geo-lndustry Since 1974 '~ 1115 Luke Street, Suite 100 Irving, Texas 75061 Phone: (972) 790-1910 · FAX: (972) 790-0967 Materials Testing Investigation Environmental CLIENT: PROJECT: CONCRETE PLACEMENT INSPECTION & STRENGTH TEST REPORT Head Construction, Inc. 3030 LB J, Suite 700 Dallas, TX 75234 Proposed Ballet Academy of Texas 145 Fitness Court Coppell, TX ATTN: Ken Head SE&T TECHNICIAN: Dominic Gonzales ISTANDARD 6" X 12" 'AREA 28.27 SQ. IN. REPORT DATE: 6/29/05 SAMPLE DATE: 6/28/05 PROJECT NO.: 286TXIK5 REPORT NO.: 18 LOCATION OF PLACEMENT: Piers # 10,11,12 & 13 PAGE 2 OF 3 Time Arrived: 8:00 AM Concrete Supplier: Southern Star Time Left: 3:45 PM 330402 5 Truck #: 1054 Concrete Temperature (FI: 91 Time Batched: 11:55 AM % Air Content: N/A Time Sampled: 12:40 PM Total No. 4 Product Code: 9329 Total Cubic Yards Placed: 30 Cement: N/A Added Water: N/A , Ash: N/A Weather Conditions: Cloud)/& Warm Coarse A~l~/re~ate: N/A 94 Water: N/A Concrete: N/A % Air Content: N/A lA 7 7/5/05 3000/28 1 B 14 7/12/05 1C 28 7/26/05 3000/28 3000/28 1 D 28 7/26/05 Curing ASTM C-31 ~ASTM C-143 Remarks: Test Method ASTM C-39 & 231 Cylinder Made By: SE&T 3000/28 Cylinders Tested By: Very Truly Yours, Sadik (SAM)AI-Musawe, MSc., Ph.D., P.E. Civil & Environmental Engineer Texas Registration Number: 61893 This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This repod only applies to the samples tested and does not necessarily represent identical or similar samples. G:120051286txik51CpistrlCpistr18LL